Accurate determination of selected pesticides in soya beans by liquid chromatography coupled to isotope dilution mass spectrometry

被引:19
|
作者
Perez, J. F. Huertas [1 ]
Sejeroe-Olsen, B. [1 ]
Fernandez Alba, A. R. [2 ]
Schimmel, H. [1 ]
Dabrio, M. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
[2] Univ Almeria, Dept Hydrogeol & Analyt Chem, European Union Reference Lab, Pesticide Residue Res Grp, La Canada De San Urbano 04120, Almeria, Spain
关键词
Pesticide; Method validation; Soya; Liquid chromatograph-mass spectrometry; Isotope dilution; Uncertainty; SOLID-PHASE EXTRACTION; MULTI-RESIDUE METHOD; LC-MS/MS; SOYBEAN OIL; VEGETABLES; MATRICES; FRUITS; STRATEGIES; QUECHERS; CLEANUP;
D O I
10.1016/j.talanta.2015.01.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, accurate and simple liquid chromatography coupled with mass spectrometry method for the determination of 10 selected pesticides in soya beans has been developed and validated. The method is intended for use during the characterization of selected pesticides in a reference material. In this process, high accuracy and appropriate uncertainty levels associated to the analytical measurements are of utmost importance. The analytical procedure is based on sample extraction by the use of a modified QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction and subsequent clean-up of the extract with C-18 PSA and Florisil. Analytes were separated on a C-18 column using gradient elution with water-methanol/2.5 mM ammonium acetate mobile phase, and finally identified and quantified by triple quadrupole mass spectrometry in the multiple reaction monitoring mode (MRM). Reliable and accurate quantification of the analytes was achieved by means of stable isotope-labelled analogues employed as internal standards (IS) and calibration with pure substance solutions containing both, the isotopically labelled and native compounds. Exceptions were made for thiodicarb and malaoxon where the isotopically labelled congeners were not commercially available at the time of analysis. For the quantification of those compounds methomyl-(C2N)-C-13-N-15 and malathion-D10 were used respectively. The method was validated according to the general principles covered by DG SANCO guidelines. However, validation criteria were set more stringently. Mean recoveries were in the range of 86-103% with RSDs lower than 8.1%. Repeatability and intermediate precision were in the range of 3.9-7.6% and 1.9-8.7% respectively. LODs were theoretically estimated and experimentally confirmed to be in the range 0.001-0.005 mg kg(-1) in thee matrix, while LOQs established as the lowest spiking mass fractionation level were in the range 0.01-0.05 mg kg(-1). The method reliably identifies and quantifies the selected pesticides in soya beans at appropriate uncertainty levels, making it suitable for the characterization of candidate reference materials. (C) 2015 The Authors. Published by Elsevier B.V.
引用
收藏
页码:120 / 129
页数:10
相关论文
共 50 条
  • [21] Accurate determination and certification of bromine in plastic by isotope dilution inductively coupled plasma mass spectrometry
    Ohata, Masaki
    Miura, Tsutomu
    ANALYTICA CHIMICA ACTA, 2014, 837 : 23 - 30
  • [22] Determination of aflatoxins in animal feeds by liquid chromatography/tandem mass spectrometry with isotope dilution
    Li, Wei
    Herrman, Timothy J.
    Dai, Susie Y.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (09) : 1222 - 1230
  • [23] Determination of Pesticides in Carrots by Gas Chromatography-Mass Spectrometry
    Covaciu, Florina D.
    Magdas, D. Alina
    Marincas, Olivian
    Moldovan, Zaharie
    ANALYTICAL LETTERS, 2017, 50 (17) : 2665 - 2676
  • [24] Determination of Cortisol in Human Serum Using Ultrasonic Extraction Coupled with Liquid Chromatography-Isotope Dilution Mass Spectrometry
    Zhou Jian
    Wang Min
    Tang Xiao-Yan
    Mao Xue-Fei
    Dai Xin-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (09) : 1439 - 1443
  • [25] Method development for the determination of 52 pesticides in tobacco by liquid chromatography-tandem mass spectrometry
    Mayer-Helm, Bernhard
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (51) : 8953 - 8959
  • [26] DETERMINATION OF CORTISOL IN HUMAN SERUM USING ULTRASONIC EXTRACTION COUPLED WITH ISOTOPE DILUTION LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    Zhou, Jian
    Dai, Xinhua
    Fang, Xiang
    Li, Hongmei
    Zhao, Yingchen
    Gong, Aijun
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2011, 39 (06) : 522 - 533
  • [27] Determination of Pesticides in Selected Cereal Products by Gas Chromatography and Ion Trap Mass Spectrometry
    Roszko, Marek
    Szymczyk, Krystyna
    CHEMIA ANALITYCZNA, 2009, 54 (06): : 1445 - 1464
  • [28] Application of gas and liquid chromatography coupled to time-of-flight mass spectrometry in pesticides: Multiresidue analysis
    Elbashir, Abdalla Ahmed
    Aboul-Enein, Hassan Y.
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (02)
  • [29] Development of isotope dilution-liquid chromatography tandem mass spectrometry for the accurate determination of vitamin K1 in spinach and kimchi cabbage
    Lee, Hyeyoung
    Lee, Joonhee
    Lee, Honghee
    Kim, Byungjoo
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2023, 14 (01)
  • [30] Development of isotope dilution-ultrahigh-performance liquid chromatography-tandem mass spectrometry for the accurate determination of aflatoxins in grains
    Lijalem, Yared Getachew
    Gab-Allah, Mohamed A.
    Yu, Hyeonwoo
    Choi, Kihwan
    Kim, Byungjoo
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 126