Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study

被引:142
|
作者
Buckinx, Fanny [1 ,2 ]
Reginster, Jean-Yves [1 ,3 ,4 ,5 ]
Dardenne, Nadia [1 ,2 ]
Croisiser, Jean-Louis [6 ]
Kaux, Jean-Francois [6 ,7 ]
Beaudart, Charlotte [1 ,2 ]
Slomian, Justine [1 ,2 ]
Bruyere, Olivier [1 ,2 ,6 ]
机构
[1] Univ Liege, Dept Publ Hlth Epidemiol & Hlth Econ, B-4000 Liege, Belgium
[2] Univ Liege, Support Unit Epidemiol & Biostat, B-4000 Liege, Belgium
[3] CHU Liege, Bone Metab Dept, B-4000 Liege, Belgium
[4] CHU Liege, Dept Publ Hlth, B-4000 Liege, Belgium
[5] CHU Liege, Bone & Cartilage Metab Dept, B-4000 Liege, Belgium
[6] Univ Liege, Dept Motr Sci, B-4000 Liege, Belgium
[7] CHU Liege, Dept Phys Med & Funct Rehabil, B-4000 Liege, Belgium
来源
BMC MUSCULOSKELETAL DISORDERS | 2015年 / 16卷
关键词
BIA; Muscle mass; Appendicular lean mass; DXA; BODY-COMPOSITION; STRENGTH MEASUREMENT; CYSTIC-FIBROSIS; GRIP STRENGTH; WHOLE-BODY; FAT MASS; RELIABILITY; VALIDITY; ADULTS; DXA;
D O I
10.1186/s12891-015-0510-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. Methods: Body composition, included appendicular lean mass divided by height squared (ALM/ht(2)) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. Results: A total of 219 subjects were enrolled in this study (mean age: 43.7 +/- 19.1 years old, 51.6% of women). For the ALM/ht(2), reliability of the test-retest of the BIA was high with an ICC of 0.89 (95% CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95% CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht(2) assessed by DXA and BIA was low (ICC = 0.37 (95% CI: 0.25-0.48)). Mean ALM/ht(2) was 9.19 +/- 1.39 kg/m(2) with BIA and 7.34 +/- 1.34 kg/m(2) with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht(2) assessed by DXA. Conclusions: Although our results show that the measure of ALM/ht(2) by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht(2) compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Body composition in subjects with anorexia nervosa: bioelectrical impedance analysis and dual-energy X-ray absorptiometry
    G. Bonaccorsi
    A. Bassetti
    S. Chiari
    P. Dirindelli
    C. Lorini
    C. Menicalli
    F. Santomauro
    M. G. Martinetti
    Eating and Weight Disorders - Studies on Anorexia, Bulimia and Obesity, 2012, 17 : e298 - e303
  • [42] Skeletal muscle estimation using magnetic-resonance-imaging-based equations for dual-energy X-ray absorptiometry and bioelectrical impedance analysis
    Tinsley, Grant M.
    LaValle, Christian
    Rodriguez, Christian
    Siedler, Madelin R.
    Heymsfield, Steven B.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2023, 77 (12) : 1151 - 1159
  • [43] Body composition in subjects with anorexia nervosa: bioelectrical impedance analysis and dual-energy x-ray absorptiometry
    Bonaccorsi, G.
    Bassetti, A.
    Chiari, S.
    Dirindelli, P.
    Lorini, C.
    Menicalli, C.
    Santomauro, F.
    Martinetti, M. G.
    EATING AND WEIGHT DISORDERS-STUDIES ON ANOREXIA BULIMIA AND OBESITY, 2012, 17 (04) : E298 - E303
  • [44] Validation of rapid 4-component body composition assessment with the use of dual-energy X-ray absorptiometry and bioelectrical impedance analysis
    Ng, Bennett K.
    Liu, Yong L.
    Wang, Wei
    Kelly, Thomas L.
    Wilson, Kevin E.
    Schoeller, Dale A.
    Heymsfield, Steven B.
    Shepherd, John A.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2018, 108 (04): : 708 - 715
  • [45] Dual energy X-ray absorptiometry: gold standard for muscle mass?
    Scafoglieri, Aldo
    Clarys, Jan Pieter
    JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2018, 9 (04): : 786 - 787
  • [46] Appendicular Body Composition Analysis: Validity of Bioelectrical Impedance Analysis Compared With Dual-Energy X-Ray Absorptiometry in Division I College Athletes
    Brewer, Gabrielle J.
    Blue, Malia N. M.
    Hirsch, Katie R.
    Peterjohn, Austin M.
    Smith-Ryan, Abbie E.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (11) : 2920 - 2925
  • [47] Body fat gain and loss differentially influence validity of dual-energy x-ray absorptiometry and multifrequency bioelectrical impedance analysis during simultaneous fat-free mass accretion
    Tinsley, Grant M.
    Moore, M. Lane
    NUTRITION RESEARCH, 2020, 75 : 44 - 55
  • [48] Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry
    Abrahamsen, B
    Hansen, TB
    Hogsberg, IM
    Pedersen, FB
    BeckNielsen, H
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 63 (01): : 80 - 86
  • [49] Prediction of Appendicular Skeletal and Fat Mass in Children: Excellent Concordance of Dual-energy X-ray Absorptiometry and Magnetic Resonance Imaging
    Bridge, Pascale
    Pocock, Nicholas A.
    Nguyen, Tuan
    Munns, Craig
    Cowell, Christopher T.
    Thompson, Martin W.
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2009, 22 (09): : 795 - 804
  • [50] Bioelectrical impedance measures in different position and vs dual-energy X-ray absorptiometry (DXA)
    Andreoli, A
    Melchiorri, G
    De Lorenzo, A
    Caruso, I
    Salimei, PS
    Guerrisi, M
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2002, 42 (02): : 186 - 189