Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: a cross-sectional study

被引:153
作者
Buckinx, Fanny [1 ,2 ]
Reginster, Jean-Yves [1 ,3 ,4 ,5 ]
Dardenne, Nadia [1 ,2 ]
Croisiser, Jean-Louis [6 ]
Kaux, Jean-Francois [6 ,7 ]
Beaudart, Charlotte [1 ,2 ]
Slomian, Justine [1 ,2 ]
Bruyere, Olivier [1 ,2 ,6 ]
机构
[1] Univ Liege, Dept Publ Hlth Epidemiol & Hlth Econ, B-4000 Liege, Belgium
[2] Univ Liege, Support Unit Epidemiol & Biostat, B-4000 Liege, Belgium
[3] CHU Liege, Bone Metab Dept, B-4000 Liege, Belgium
[4] CHU Liege, Dept Publ Hlth, B-4000 Liege, Belgium
[5] CHU Liege, Bone & Cartilage Metab Dept, B-4000 Liege, Belgium
[6] Univ Liege, Dept Motr Sci, B-4000 Liege, Belgium
[7] CHU Liege, Dept Phys Med & Funct Rehabil, B-4000 Liege, Belgium
关键词
BIA; Muscle mass; Appendicular lean mass; DXA; BODY-COMPOSITION; STRENGTH MEASUREMENT; CYSTIC-FIBROSIS; GRIP STRENGTH; WHOLE-BODY; FAT MASS; RELIABILITY; VALIDITY; ADULTS; DXA;
D O I
10.1186/s12891-015-0510-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. Methods: Body composition, included appendicular lean mass divided by height squared (ALM/ht(2)) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. Results: A total of 219 subjects were enrolled in this study (mean age: 43.7 +/- 19.1 years old, 51.6% of women). For the ALM/ht(2), reliability of the test-retest of the BIA was high with an ICC of 0.89 (95% CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95% CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht(2) assessed by DXA and BIA was low (ICC = 0.37 (95% CI: 0.25-0.48)). Mean ALM/ht(2) was 9.19 +/- 1.39 kg/m(2) with BIA and 7.34 +/- 1.34 kg/m(2) with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht(2) assessed by DXA. Conclusions: Although our results show that the measure of ALM/ht(2) by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht(2) compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
引用
收藏
页数:7
相关论文
共 27 条
[1]   Effect of the Lengthening of the Protocol on the Reliability of Muscle Fatigue Indicators [J].
Bosquet, L. ;
Maquet, D. ;
Forthomme, B. ;
Nowak, N. ;
Lehance, C. ;
Croisier, J. -L. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2010, 31 (02) :82-88
[2]   Sarcopenia: European consensus on definition and diagnosis [J].
Cruz-Jentoft, Alfonso J. ;
Baeyens, Jean Pierre ;
Bauer, Juergen M. ;
Boirie, Yves ;
Cederholm, Tommy ;
Landi, Francesco ;
Martin, Finbarr C. ;
Michel, Jean-Pierre ;
Rolland, Yves ;
Schneider, Stephane M. ;
Topinkova, Eva ;
Vandewoude, Maurits ;
Zamboni, Mauro .
AGE AND AGEING, 2010, 39 (04) :412-423
[3]   Sarcopenia Definitions Considering Body Size and Fat Mass Are Associated With Mobility Limitations: The Framingham Study [J].
Dufour, Alyssa B. ;
Hannan, Marian T. ;
Murabito, Joanne M. ;
Kiel, Douglas P. ;
McLean, Robert R. .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2013, 68 (02) :168-174
[4]   PSA and Body Composition by Dual X-Ray Absorptiometry (DXA) in NHANES [J].
Fowke, Jay H. ;
Matthews, Charles E. .
PROSTATE, 2010, 70 (02) :120-125
[5]   Anthropometry, bioelectrical impedance and dual-energy X-ray absorptiometry in the assessment of body composition in elderly Finnish women [J].
Haapala, I ;
Hirvonen, A ;
Niskanen, L ;
Uusitupa, M ;
Kröger, H ;
Alhava, E ;
Nissinen, A .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (06) :383-391
[6]   The Official Positions of the International Society for Clinical Densitometry: Acquisition of Dual-Energy X-Ray Absorptiometry Body Composition and Considerations Regarding Analysis and Repeatability of Measures [J].
Hangartner, Thomas N. ;
Warner, Sarah ;
Braillon, Pierre ;
Jankowski, Larry ;
Shepherd, John .
JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (04) :520-536
[7]   RELIABILITY AND VALIDITY OF BIOELECTRICAL IMPEDANCE IN DETERMINING BODY-COMPOSITION [J].
JACKSON, AS ;
POLLOCK, ML ;
GRAVES, JE ;
MAHAR, MT .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (02) :529-534
[8]   Validation of a portable bioelectrical impedance analyzer for the assessment of body composition [J].
Karelis, Antony D. ;
Chamberland, Gabriel ;
Aubertin-Leheudre, Mylene ;
Duval, Christian .
APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME, 2013, 38 (01) :27-32
[9]   Assessment of appendicular skeletal muscle mass by bioimpedance in older community-dwelling Korean adults [J].
Kim, Jung Hee ;
Choi, Sung Hee ;
Lim, Soo ;
Kim, Ki Woong ;
Lim, Jae Young ;
Cho, Nam H. ;
Park, Kyong Soo ;
Jang, Hak Chul .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2014, 58 (03) :303-307
[10]   Accuracy of segmental multi-frequency bioelectrical impedance analysis for assessing whole-body and appendicular fat mass and lean soft tissue mass in frail women aged 75 years and older [J].
Kim, M. ;
Kim, H. .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (04) :395-400