Indium determination using slotted quartz tube-atom trap-flame atomic absorption spectrometry and interference studies

被引:42
作者
Arslan, Yasin [2 ]
Kenduzler, Erdal [1 ]
Ataman, O. Yavuz [2 ]
机构
[1] Mehmet Akif Ersoy Univ, Dept Chem, Art & Sci Fac, TR-15030 Burdur, Turkey
[2] Middle E Tech Univ, Dept Chem, Art & Sci Fac, TR-06531 Ankara, Turkey
关键词
Indium; Flame atomic absorption spectrometry; Slotted quartz tube; Atom trap; X-ray Photoelectron Spectrometry; Montana Soil; SPECIATION DETERMINATION; CADMIUM; LEAD; SENSITIVITY; PRECONCENTRATION; GENERATION;
D O I
10.1016/j.talanta.2011.07.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitivity enhancement of indium determination by flame atomic absorption spectrometry (FAAS) was achieved: using a slotted quartz tube (SQT-FAAS) and slotted quartz tube atom trap (SQT-AT-FAAS). SQT was used as an atom trap (AT) where the analyte is accumulated in its inner wall prior to re-atomization. The signal is formed after re-atomization of analyte on the trap surface by introduction of 10 pi of isobutyl methyl ketone (IBMK). Sensitivity was improved 400 times using SQT-AT-FAAS system with respect to conventional FAAS and 279 times with respect to SQT-FAAS without any collection. Characteristic concentration (C-o) and limit of detection values were found to be 3.63 ng mL(-1) and 2.60 ng mL(-1), respectively, using a sample flow rate of 7.0 mL min(-1) and a collection period of 5.0 min. In addition, interference effects of some elements on indium signal were studied. In order to characterize indium species trapped, X-ray Photoelectron Spectrometry (XPS) was utilized and it was found that indium was collected on the inner surface of SQT as In2O3. The accuracy of the procedure was checked to determine indium in the standard reference material (Montana Soil, SRM 2710). Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1786 / 1791
页数:6
相关论文
共 24 条
[1]   Vapor generation and atom traps: Atomic absorption spectrometry at the ng/L level [J].
Ataman, O. Yavuz .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (08) :825-834
[2]  
Ataman OY, 2007, PAK J ANAL ENV CHEM, V8
[3]  
Dedina J., 1995, HYDRIDE GENERATION A, V1st
[4]  
Ebdon L., 1988, INTRO ANAL SPECTROME
[5]   Novel traps and atomization techniques for flame AAS [J].
Ertas, N ;
Korkmaz, DK ;
Kumser, S ;
Ataman, OY .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1415-1420
[6]  
Ertas N., 1993, FED AN CHEM SPECTR S
[7]  
Huang G., 1995, ZIRAN KEXUEBAN HUA X, V41, P707
[8]   Online preconcentration for the determination of lead, cadmium and copper by slotted tube atom trap (STAT)-flame atomic absorption spectrometry [J].
Kaya, Gokce ;
Yaman, Mehmet .
TALANTA, 2008, 75 (04) :1127-1133
[9]   Interference studies in slotted silica tube trap technique [J].
Korkmaz, D ;
Mahmut, M ;
Helles, R ;
Ertas, N ;
Ataman, OY .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (02) :99-104
[10]   Investigations on nature of re-volatilization from atom trap surfaces in flame AAS [J].
Korkmaz, D ;
Kumser, S ;
Ertas, N ;
Mahmut, M ;
Ataman, OY .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (12) :1610-1614