An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery

被引:20
作者
Capaldi, Dante P., I [1 ]
Skinner, Lawrie B. [1 ]
Dubrowski, Piotr [1 ]
Yu, Amy S. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
3D printing; QA; stereotactic radiosurgery; frameless brain SRS treatment; off-axis Winston-Lutz; single-isocenter multitarget SRS; BODY RADIATION-THERAPY; LINEAR-ACCELERATOR; PRACTICE GUIDELINE; FILM DOSIMETRY; TECHNICAL NOTE; ACCURACY; BRAIN; QA;
D O I
10.1088/1361-6560/ab8534
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel brain SRS integrated phantom was developed and validated to enable SRS QA with a single phantom to facilitate implementation of a frameless single-isocenter, multitarget SRS program. This phantom combines the independent verification of each positioning system, the Winston-Lutz, off-axis accuracy evaluation (i.e. off-axis Winston-Lutz), and the dosimetric accuracy utilizing both point dose measurements as well as film measurement, without moving the phantom. A novel 3D printed phantom, coined OneIso, was designed with a movable insert which can switch between the Winston-Lutz test target and dose measurement without moving the phantom itself. For dose verification, ten brain SRS clinical treatment plans with 10 MV flattening-filter-free beams were delivered on a Varian TrueBeam with a high-definition multileaf collimator (HD-MLC). Radiochromic film and pinpoint ion chamber comparison measurements were made between the OneIso and solid water (SW) phantom setups. For the off-axis Winston-Lutz measurements, a row of off-axis ball bearings (BBs) was integrated into the OneIso. To quantify the spatial accuracy versus distance from the isocenter, two-dimensional displacements were calculated between the planned and delivered BB locations relative to their respective MLC defined field border. OneIso and the SW phantoms agree within 1%, for both film and point dose measurements. OneIso identified a reduction in spatial accuracy further away from the isocenter. Differences increased as distance from the isocenter increased, exceeding recommended SRS accuracy tolerances at 7 cm away from the isocenter. OneIso provides a streamlined, single-setup workflow for single-isocenter multitarget frameless linac-based SRS QA. Additionally, with the ability to quantify off-axis spatial discrepancies, we can determine limitations on the maximum distance between targets to ensure a single-isocenter multitarget SRS program meets recommended guidelines.
引用
收藏
页数:16
相关论文
共 42 条
  • [1] Delivered Dose Distribution Visualized Directly With Onboard kV-CBCT: Proof of Principle
    Adamson, Justus
    Carroll, Jaclyn
    Trager, Michael
    Yoon, Suk Whan
    Kodra, Jacob
    Maynard, Evan
    Hilts, Michelle
    Oldham, Mark
    Jirasek, Andrew
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 103 (05): : 1271 - 1279
  • [2] Comprehensive evaluation of the high-resolution diode array for SRS dosimetry
    Ahmed, Saeed
    Zhang, Geoffrey
    Moros, Eduardo G.
    Feygelman, Vladimir
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 13 - 23
  • [3] GENERALIZING THE HOUGH TRANSFORM TO DETECT ARBITRARY SHAPES
    BALLARD, DH
    [J]. PATTERN RECOGNITION, 1981, 13 (02) : 111 - 122
  • [4] Stereotactic body radiation therapy: The report of AAPM Task Group 101
    Benedict, Stanley H.
    Yenice, Kamil M.
    Followill, David
    Galvin, James M.
    Hinson, William
    Kavanagh, Brian
    Keall, Paul
    Lovelock, Michael
    Meeks, Sanford
    Papiez, Lech
    Purdie, Thomas
    Sadagopan, Ramaswamy
    Schell, Michael C.
    Salter, Bill
    Schlesinger, David J.
    Shiu, Almon S.
    Solberg, Timothy
    Song, Danny Y.
    Stieber, Volker
    Timmerman, Robert
    Tome, Wolfgang A.
    Verellen, Dirk
    Wang, Lu
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2010, 37 (08) : 4078 - 4101
  • [5] FRAMELESS IMAGE-GUIDED INTRACRANIAL STEREOTACTIC RADIOSURGERY: CLINICAL OUTCOMES FOR BRAIN METASTASES
    Breneman, John C.
    Steinmetz, Ryan
    Smith, Aaron
    Lamba, Michael
    Warnick, Ronald E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 702 - 706
  • [6] Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
    Bush, K.
    Gagne, I. M.
    Zavgorodni, S.
    Ansbacher, W.
    Beckham, W.
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2208 - 2221
  • [7] FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES
    Clark, Grant M.
    Popple, Richard A.
    Young, P. Edward
    Fiveash, John B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01): : 296 - 302
  • [8] Adaptation and validation of a commercial head phantom for cranial radiosurgery dosimetry end-to-end audit
    Dimitriadis, Alexis
    Palmer, Antony L.
    Thomas, Russell A. S.
    Nisbet, Andrew
    Clark, Catharine H.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1074)
  • [9] The spatial accuracy of two frameless, linear accelerator-based systems for single-isocenter, multitarget cranial radiosurgery
    Ezzell, Gary A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 37 - 43
  • [10] Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery
    Faught, Austin M.
    Trager, Michael
    Yin, Fang-Fang
    Kirkpatrick, John
    Adamson, Justus
    [J]. MEDICAL PHYSICS, 2016, 43 (10) : 5437 - 5441