Performance of Loop-Mediated Isothermal Amplification Assay for Diagnosis of Extrapulmonary Tuberculosis and Antituberculosis Treatment Initiation

被引:5
|
作者
Singh, Priyanka [1 ]
Kanade, Swapna [1 ]
Nataraj, Gita [1 ]
机构
[1] Seth GS Med Coll & King Edward Mem Hosp, Dept Microbiol, Acharya Donde Marg, Mumbai 400012, Maharashtra, India
关键词
Extrapulmonary tuberculosis; loop-mediated isothermal amplification assay; molecular assay; Mycobacterium tuberculosis; tuberculosis diagnosis; MTB/RIF ASSAY; LAMP ASSAY; PULMONARY; PCR;
D O I
10.4103/ijmy.ijmy_218_21
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Extra-pulmonary TB(EPTB) accounts for 15-20% of total TB cases in India. Many cases remain undiagnosed due to poor sensitivity/long turn-around-time of conventional diagnostic tests. Molecular tests offer rapidity, improved sensitivity and exquisite specificity, but are expensive, require skilled manpower and enhanced laboratory infrastructure. Loop-mediated isothermal amplification (LAMP) assay is a unique, temperature-independent DNA amplification test facilitated by visual optic-readout. WHO has recommended use of LAMP for pulmonary TB diagnosis in 2016. For END-TB strategy to succeed, its necessary to capture all forms of TB. The aim of the study was to determine the sensitivity and specificity of LAMP assay against culture, Xpert MTB/RIF assay and Composite Reference Standard(CRS) for diagnosis of EPTB. Methods: In a cross-sectional study hundred consecutive EPTB specimens were processed for microscopy, culture, Xpert and LAMP assay. Standard formulae of sensitivity and specificity and McNemar chi square test of significance was applied. Results: Hundred specimens included in the study were fluids(65), pus(19) and tissue(16). TB was detected in 38 specimens by any of the four methods. Positivity of microscopy-5%, culture-28%, Xpert-25% and LAMP-32%. Sensitivity and specificity of LAMP against culture was 85.71% and 88.89%; against Xpert was 88% and 86.67%; against CRS was 80% and 88.6% respectively. LAMP detected TB in 32 patients of which 28 were put on anti-TB treatment (ATT). Of the 62 patients with negative results in all the tests, 22 were put on ATT. Conclusions: LAMP has good sensitivity for EPTB diagnosis. Further studies are required to establish utility of LAMP as EPTB diagnostic tool.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 50 条
  • [31] A Rapid Loop-Mediated Isothermal Amplification Assay Targeting hspX for the Detection of Mycobacterium tuberculosis Complex
    Bi, Aixiao
    Nakajima, Chie
    Fukushima, Yukari
    Tamaru, Aki
    Sugawara, Isamu
    Kimura, Akio
    Kawahara, Ryuji
    Hu, Zhongyi
    Suzuki, Yasuhiko
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2012, 65 (03) : 247 - 251
  • [32] Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis
    Baye Gelaw
    Yitayal Shiferaw
    Marta Alemayehu
    Abate Assefa Bashaw
    BMC Infectious Diseases, 17
  • [33] Loop-Mediated Isothermal Amplification test for the diagnosis of pertussis in Japan
    Nawa, Nobutoshi
    VACCINE, 2018, 36 (06) : 771 - 771
  • [34] Diagnosis of Ruminant Viral Diseases with Loop-Mediated Isothermal Amplification
    Sanem Ayaz Kök
    Selcen Üstün
    Hümeyra Taşkent Sezgin
    Molecular Biotechnology, 2023, 65 : 1228 - 1241
  • [35] Loop-Mediated isothermal Amplification Methods for Diagnosis of Bacterial Meningitis
    Seki, Mitsuko
    Kilgore, Paul E.
    Kim, Eun Jin
    Ohnishi, Makoto
    Hayakawa, Satoshi
    Kim, Dong Wook
    FRONTIERS IN PEDIATRICS, 2018, 6
  • [36] Diagnosis of Ruminant Viral Diseases with Loop-Mediated Isothermal Amplification
    Kok, Sanem Ayaz
    Ustun, Selcen
    Sezgin, Humeyra Taskent
    MOLECULAR BIOTECHNOLOGY, 2023, 65 (08) : 1228 - 1241
  • [37] MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
    Ocker, Ronja
    Prompunjai, Yongyut
    Chutipongvivate, Salakchit
    Karanis, Panagiotis
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2016, 58
  • [38] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [39] Loop-Mediated Isothermal Amplification for the Diagnosis of Sporotrichosis by Sporothrix brasiliensis
    Araujo, Marcella Donadel
    Poester, Vanice Rodrigues
    Schirmer, Helena
    Mattevi, Vanessa Sune
    Trapaga, Mariana Rodrigues
    Xavier, Melissa Orzechowski
    Teixeira, Marcus de Melo
    Almeida-Paes, Rodrigo
    Zancope-Oliveira, Rosely Maria
    Severo, Cecilia Bittencourt
    MYCOPATHOLOGIA, 2024, 189 (05)
  • [40] Loop-mediated isothermal amplification test for the molecular diagnosis of malaria
    Han, Eun-Taek
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (02) : 205 - 218