Evaluation of a magnetic particles-based chemiluminescence enzyme immunoassay for Golgi protein 73 in human serum

被引:14
|
作者
Liu, Xiangyi [1 ]
Wan, Xiaohua [1 ]
Lu, Sheng [2 ]
Zhang, Lijun [3 ]
Yu, Shaohua [4 ]
Lu, Xinxin [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Dept Lab Med, Beijing 100730, Peoples R China
[2] Beijing Ranos Med Technol Co Ltd, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Tongren Hosp, Dept Surg, Beijing 100730, Peoples R China
[4] Beijing Hotgen Biotechnol Co Ltd, Beijing, Peoples R China
关键词
Golgi protein 73; Chemiluminescence enzyme immunoassay; Evaluation; Magnetic particles; Hepatocellular carcinoma; ALPHA-FETOPROTEIN AFP; HEPATOCELLULAR-CARCINOMA; LIVER-DISEASES; GP73; MARKER; EXPRESSION; DIAGNOSIS; ANTIGEN; GOLPH2; SYSTEM;
D O I
10.1016/j.cca.2015.03.008
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Golgi protein 73 (GP73) is regarded as a potential serum biomarker for early diagnosis of hepatocellular carcinoma (HCC). We developed a rapid magnetic particles-based chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of serum GP73. Methods: Fluorescein isothiocyanate (FITC) and alkaline phosphatase (ALP) were used to label 2 different monoclonal antibodies to GP73. Serum GP73 was captured with labeled antibodies and formed a sandwiched immunoreaction. The magnetic particles (MPs) coated with anti-FITC antibody were used as a means of separation of the GP73 protein from other serum proteins. After adding the enzyme substrate solution, the relative light unit (RLU) was measured. A MPs-CLEIA for serum GP73 was established and evaluated. Results: The RLU was directly proportional to the concentration of GP73. The method linearity was 5-600 mu g/I. Limit of the blank was 2.19 mu g/I. The intra- and inter-assay imprecision was <3% and <5%, respectively. The average recoveries were between 95% and 105%. The proposed method showed a good correlation with a commercial ELISA assay (r = 0.983, p < 0.001). We also evaluated the efficiency of serum GP73 measurement for the diagnosis of HCC using this assay. The area under the receiver operating characteristic curve was 0.822 (95% CI, 0.73-0.89), and the sensitivity and specificity, with cut-off value of 115.6 mu g/I, were 75.4% and 92.1%, respectively. Conclusions: The proposed method demonstrates an acceptable performance for quantifying serum GP73. This assay could be appropriate for routine use in clinical laboratories. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 47 条
  • [21] Microplate chemiluminescence enzyme immunoassay for the quantitative evaluation of carbohydrate antigen 72-4 in human serum
    JIN Hui1
    2 Department of Chemistry
    3 Beijing Chemclin Biotech Co.
    Chinese Science Bulletin, 2008, (19) : 2958 - 2963
  • [22] Microplate chemiluminescence enzyme immunoassay for the quantitative evaluation of carbohydrate antigen 72-4 in human serum
    Jin Hui
    Wang Xu
    Xin TianBing
    Gao Peng
    Lin Jin-Ming
    Liang ShuXuan
    CHINESE SCIENCE BULLETIN, 2008, 53 (19): : 2958 - 2963
  • [23] Magnetic particle-based chemiluminescence immunoassay for serum human heart-type fatty acid binding protein measurement
    Jiao Zheng
    Yilan Qiu
    Ye Xu
    Meifang Quan
    Zhihong Zhong
    Qinglin Wang
    Yi Wu
    Xuan Zeng
    Chuan Xia
    Rushi Liu
    Biotechnology Letters, 2023, 45 : 1431 - 1440
  • [24] Magnetic particle-based chemiluminescence immunoassay for serum human heart-type fatty acid binding protein measurement
    Zheng, Jiao
    Qiu, Yilan
    Xu, Ye
    Quan, Meifang
    Zhong, Zhihong
    Wang, Qinglin
    Wu, Yi
    Zeng, Xuan
    Xia, Chuan
    Liu, Rushi
    BIOTECHNOLOGY LETTERS, 2023, 45 (11-12) : 1431 - 1440
  • [25] Micro-plate chemiluminescence enzyme immunoassay for clinical determination of progesterone in human serum
    Ren Shi-Qi
    Wang Xu
    Tang Bao-Jun
    Hu Guo-Mao
    Li Zhen-Jia
    Chen Guo-Nan
    Lin Jin-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (06) : 729 - 734
  • [26] Development of a rapid and sensitivity magnetic chemiluminescence immunoassay for DNA methyltransferase 1 in human serum
    He, Sitian
    He, Leiliang
    Liu, Beibei
    Yu, Songcheng
    Liu, Li'e
    Tian, Yongmei
    Wang, Jia
    Ding, Lihua
    Wang, Yilin
    Qu, Lingbo
    Yu, Fei
    Wu, Yongjun
    CHINESE CHEMICAL LETTERS, 2019, 30 (05) : 1031 - 1034
  • [27] Development of a rapid and sensitivity magnetic chemiluminescence immunoassay for DNA methyltransferase 1 in human serum
    Sitian He
    Leiliang He
    Beibei Liu
    Songcheng Yu
    Li'e Liu
    Yongmei Tian
    Jia Wang
    Lihua Ding
    Yilin Wang
    Lingbo Qu
    Fei Yu
    Yongjun Wu
    ChineseChemicalLetters, 2019, 30 (05) : 1031 - 1034
  • [28] Microplate chemiluminescence enzyme immunoassay for the quantitative analysis of free prostate-specific antigen in human serum
    Shi Gen
    Tang Bao-Jun
    Wang Xu
    Zhao Li-Xia
    Lin Jin-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (11) : 1541 - 1547
  • [29] The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer
    Fu, Xiaoling
    Liu, Yangyang
    Qiu, Ruiyun
    Foda, Mohamed F.
    Zhang, Yong
    Wang, Tao
    Li, Jinshan
    BIOCHEMISTRY AND BIOPHYSICS REPORTS, 2018, 13 : 73 - 77
  • [30] Magnetic microbead-based enzyme-linked immunoassay for detection of Schistosoma japonicum antibody in human serum
    Liu, Zhenshi
    Zhang, Li
    Yang, Hai
    Zhu, Yanhong
    Jin, Wei
    Song, Qian
    Yang, Xiangliang
    ANALYTICAL BIOCHEMISTRY, 2010, 404 (02) : 127 - 134