Rapid amperometric determination of H2O2 by a Pt nanoparticle/Vulcan XC72 composite-coated carbon paste electrode in disinfection and contact lens solutions

被引:7
作者
Anojcic, Jasmina [1 ]
Guzsvany, Valeria [1 ]
Vajdle, Olga [1 ]
Konya, Zoltan [2 ,3 ]
Kalcher, Kurt [4 ]
机构
[1] Univ Novi Sad, Dept Chem Biochem & Environm Protect, Fac Sci, Novi Sad, Serbia
[2] Univ Szeged, Dept Appl & Environm Chem, Szeged, Hungary
[3] MTA SZTE React Kinet & Surface Chem Res Grp, Szeged, Hungary
[4] Karl Franzens Univ Graz, Inst Chem Analyt Chem, Graz, Austria
来源
MONATSHEFTE FUR CHEMIE | 2018年 / 149卷 / 10期
关键词
Electrochemistry; Voltammetry; Sensors; Hydrogen peroxide; Pt nanoparticles and Vulcan XC72; Carbon paste electrode; HYDROGEN-PEROXIDE SENSOR; PLATINUM NANOPARTICLES; FIBER MICROELECTRODE; ENZYME-FREE; NANOTUBES; GLUCOSE; PARTICLES; GOLD; NANOCOMPOSITE; OXIDATION;
D O I
10.1007/s00706-018-2253-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The presentwork describes the preparation of a simple, sensitive, and reliableH(2)O(2) sensor made fromcarbon paste surfacemodified with a composite of platinum nanoparticles (< 5 nm) on graphitized carbon (Pt-C, 10% Pt on Vulcan XC72) by simply dropcoating. The unmodified carbon paste electrode (CPE) and the modified one (Pt-C/CPE) were characterized by scanning electron microscopy in combination with energy- dispersive X-ray spectrometry and by cyclic voltammetry. The Pt-C/CPE showed remarkable electrocatalytic properties toward the electrochemical redox reaction of H2O2 compared to CPE in phosphate (0.1 mol dm(-3); pH 7.50) and acetate (0.1 mol dm(-3); pH 4.50) buffer supporting electrolytes. Amperometry of H2O2 in the concentration range from 0.15 to 1.45 mu g cm(-3) with the Pt- C/CPE showed acceptable linearity, while the obtained values of LOQs were 0.06 mu g cm(-3) (pH 7.50, working potential 0.20 V, stirred solution) and 0.10 mu g cm(-3) (pH 4.50, working potential 0.50 V). The proposed analytical methods were applied to the determination of the H2O2 content in commercially available personal care products: disinfection (pH 7.50) and contact lens cleaning (pH 4.50) solutions. In both cases, obtained amperometric results are in good agreement with those measured by the traditional spectrophotometric method and with H2O2 concentration declared by producers. The Pt- C/CPE was also tested for monitoring of the H2O2 residual concentration in contact lens solution during its neutralization/decomposition process by solid Pt catalyst. At 6 h of neutralization treatment, 24.68 mu g cm(-3) of the H2O2 was determined which is below allowed H2O2 concentration concerning the limit of eye irritation.
引用
收藏
页码:1727 / 1738
页数:12
相关论文
共 49 条
[1]   Hydrodynamic chronoamperometric determination of hydrogen peroxide using carbon paste electrodes coated by multiwalled carbon nanotubes decorated with MnO2 or Pt particles [J].
Anojcic, Jasmina ;
Guzsvany, Valeria ;
Vajdle, Olga ;
Madarasz, Daniel ;
Ronavari, Andrea ;
Konya, Zoltan ;
Kalcher, Kurt .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 :83-92
[2]   Carbon supports for low-temperature fuel cell catalysts [J].
Antolini, Ermete .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2009, 88 (1-2) :1-24
[3]  
Aricò AS, 2001, FUEL CELLS, V1, P133
[4]   Ag-supported nanozeolite L-modified electrode: a new high performance nonenzymatic hydrogen peroxide sensor [J].
Azizi, Seyed Naser ;
Ghasemi, Shahram ;
Gilani, Neda Salek .
MONATSHEFTE FUR CHEMIE, 2016, 147 (09) :1467-1474
[5]   Ultra-fine Pt nanoparticles supported on ionic liquid polymer-functionalized ordered mesoporous carbons for nonenzymatic hydrogen peroxide detection [J].
Bo, Xiangjie ;
Bai, Jing ;
Qi, Bin ;
Guo, Liping .
BIOSENSORS & BIOELECTRONICS, 2011, 28 (01) :77-83
[6]   Nonenzymatic amperometric sensor of hydrogen peroxide and glucose based on Pt nanoparticles/ordered mesoporous carbon nanocomposite [J].
Bo, Xiangjie ;
Ndamanisha, Jean Chrysostome ;
Bai, Jing ;
Guo, Liping .
TALANTA, 2010, 82 (01) :85-91
[7]   Nanomaterials based electrochemical sensors for biomedical applications [J].
Chen, Aicheng ;
Chatterjee, Sanghamitra .
CHEMICAL SOCIETY REVIEWS, 2013, 42 (12) :5425-5438
[8]   Bimetallic PtM (M = Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for H2O2 [J].
Chen, Kuan-Jung ;
Pillai, K. Chandrasekara ;
Rick, John ;
Pan, Chun-Jern ;
Wang, Shih-Han ;
Liu, Chung-Chiun ;
Hwang, Bing-Joe .
BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) :120-127
[9]   Electrochemical sensing of hydrogen peroxide using metal nanoparticles: a review [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Hu, Fangxin .
MICROCHIMICA ACTA, 2013, 180 (1-2) :15-32
[10]   Recent advances in electrochemical sensing for hydrogen peroxide: a review [J].
Chen, Wei ;
Cai, Shu ;
Ren, Qiong-Qiong ;
Wen, Wei ;
Zhao, Yuan-Di .
ANALYST, 2012, 137 (01) :49-58