Increase in the boiler's performance in terms of the acid dew point temperature:: Environmental advantages of replacing fuels

被引:59
作者
Blanco, J. M. [1 ]
Pena, F. [1 ]
机构
[1] Univ Basque Country, Dpto Maquinas & Motores Termicos, Escuela Tecn Super Ingn, EHU, Bilbao 48013, Spain
关键词
acid dew point; pre-heaters; low sulphur fuel;
D O I
10.1016/j.applthermaleng.2007.06.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of air pre-heaters is to raise the temperature of the combustion air in boilers, using heat recovered from the power plant combustion gases. On the one hand, this paper compares the effects of the acid dew point temperature (ADT) on pre-heaters in a reference thermal power plant for two types of fuel, 'fuel No. 2" and "low sulphur fuel" respectively and on the other hand, it shows how a changeover to this latter fuel would increase the useful lifetime of this equipment, reducing this way cost of maintenance due to the considerable decrease in the area exposed to ADT with the subsequent increase in the boiler's performance. (c) 2007 Elsevier Ltd. All rights reserved.