摘要
Performance assessment of a two-bed silica gel-water adsorption refrigeration system driven by solar thermal energy is carried out under a climatic condition typical of Perth, Australia. A Fourier series is used to simulate solar radiation based on the actual data obtained from Meteonorm software, version 7.0 for Perth, Australia. Two economic methodologies, Payback Period and Life-Cycle Saving are used to evaluate the system economics and optimize the need for solar collector areas. The analysis showed that the order of Fourier series did not have a significant impact on the simulation radiation data and a three-order Fourier series was good enough to approximate the actual solar radiation. For a typical summer day, the average cooling capacity of the chiller at peak hour (13:00) is around 11 kW while the cyclic chiller system coefficient of performance (COP) and solar system COP are around 0.5 and 0.3, respectively. The economic analysis showed that the payback period for the solar adsorption system studied was about 11 years and the optimal solar collector area was around 38 m(2) if a compound parabolic collector (CPC) panel was used. The study indicated that the utilization of the solar-driven adsorption cooling is economically and technically viable for weather conditions like those in Perth, Australia.
引用
收藏
页数:19
相关论文
共 16 条
  • [1] Performance evaluation of a solar adsorption chiller under different climatic conditions
    Alahmer, Ali
    Wang, Xiaolin
    Al-Rbaihat, Raed
    Alam, K. C. Amanul
    Saha, B. B.
    APPLIED ENERGY, 2016, 175 : 293 - 304
  • [2] NUMERICAL SIMULATION OF A TWO-BED SOLAR-DRIVEN ADSORPTION CHILLER IN A TROPICAL CLIMATE
    Nasruddin
    Lemington
    Alhamid, Muhammad Idrus
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2015, 6 (04) : 594 - 603
  • [3] Performance Investigation of a Two-Bed Type Adsorption Chiller with Various Adsorbents
    Lee, Jung-Gil
    Bae, Kyung Jin
    Kwon, Oh Kyung
    ENERGIES, 2020, 13 (10)
  • [4] Water adsorption on CHA and AFI types zeolites: Modelling and investigation of adsorption chiller under static and dynamic conditions
    Teo, How Wei Benjamin
    Chakraborty, Anutosh
    Han, Bo
    APPLIED THERMAL ENGINEERING, 2017, 127 : 35 - 45
  • [5] MULTI-OBJECTIVE OPTIMIZATION OF A TWO-BED SOLAR ADSORPTION CHILLER BASED ON EXERGY AND ECONOMICS
    Djubaedah, Euis
    Rachmat, Asep
    Aisyah, Nyayu
    Nasruddin
    Kurniawan, Andre
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2018, 9 (06) : 1276 - 1284
  • [6] Thermo-environ-economic evaluation of a trigeneration system based on thermoelectric generator, two-bed adsorption chiller, and polymer exchange membrane fuel cell
    Ebrahimi, Masood
    Derakhshan, Ehsan
    ENERGY CONVERSION AND MANAGEMENT, 2019, 180 : 269 - 280
  • [7] Experimental investigation on the dynamic performance of a solar thermally-driven adsorption chiller integrated with a gas boiler
    Fuentes, Elena
    Impala, Veronica
    Bellanco, Ivan
    Salom, Jaume
    Sayans, Alejandra
    Balsells, Miquel
    Sanjoaquin, Silvia
    Mogro, Oscar
    PROCEEDINGS OF THE ISES EUROSUN 2018 CONFERENCE - 12TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2018, : 585 - 596
  • [8] Dynamic thermal model of solar PV systems under varying climatic conditions
    Lobera, Diego Torres
    Valkealahti, Seppo
    SOLAR ENERGY, 2013, 93 : 183 - 194
  • [9] Modeling the performance of a two-bed solar adsorption chiller using a multi-walled carbon nanotube/MIL-100(Fe) composite adsorbent
    ul Qadir, Najam
    Said, Syed A. M.
    Ben Mansour, Rached
    RENEWABLE ENERGY, 2017, 109 : 602 - 612
  • [10] Performance prediction of a two-bed solar adsorption chiller with adaptive cycle time using a MIL-100(Fe)/water working pair - influence of solar collector configuration
    ul Qadir, Najam
    Said, Syed A. M.
    Mansour, Rached Ben
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 : 472 - 488