Pre-closure of femoral venous access sites used for large-sized sheath insertion with the Perclose device in adults undergoing cardiac intervention

被引:32
作者
Mahadevan, V. S. [1 ]
Jimeno, S. [1 ]
Benson, L. N. [1 ]
McLaughlin, P. R. [1 ]
Horlick, E. M. [1 ]
机构
[1] Toronto Gen Hosp, Toronto, ON M5G 2C4, Canada
关键词
D O I
10.1136/hrt.2006.095935
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Interventional procedures in adults with congenital cardiac conditions often require insertion of large-sized sheaths into the femoral veins. Data on the use of suture-mediated devices for femoral venous access site closure are scant and no data are available regarding venous patency after device use. Objective: To assess the efficacy of the 6Fr Perclose (Abbott Vascular Devices, CA, USA) suture-mediated device in achieving haemostasis and venous patency after closure. Design and setting: 146 consecutive patients (80 women, mean (SD) age 45 (14) years) undergoing closure of 205 femoral venous access sites in a tertiary cardiac centre were studied. All received heparin and were taking concomitant aspirin or clopidogrel, or both. The majority (98%) had a >= 10Fr sheath inserted. Results: Immediate haemostasis was achieved in 202 (99%) sites. Two patients (1.4%) had a major complication. On follow-up (111 patients, mean (SD) 71 (33) days) there was no evidence of haematoma or fistula formation. Doppler studies from a subgroup of 43 (29%) patients (mean (SD) age 45 (15) years, mean (SD) follow-up 47 ( 18) days) showed a common femoral venous diameter of 11.6 (2.7) mm on the device closed right and 12.2 (2.5) mm on the left vein (p > 0.05). All accessed veins were patent with no pseudoaneurysm or arteriovenous fistula formation. Conclusion: Pre-closure of large-size sheath femoral venous access sites using the suture-mediated Perclose device is efficacious in achieving rapid haemostasis in the presence of anticoagulation. Doppler follow-up shows no loss of venous patency or luminal venous diameter as compared with the contralateral side.
引用
收藏
页码:571 / 572
页数:2
相关论文
共 5 条
[1]   Closure of the femoral vein puncture site after transcatheter procedures using angio-seal [J].
Coto, HA .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (01) :16-19
[2]  
Macchi Claudio, 1996, Italian Journal of Anatomy and Embryology, V101, P107
[3]   Vascular closure devices and the risk of vascular complications after percutaneous coronary intervention in patients receiving glycoprotein IIb-IIIa inhibitors [J].
Resnic, FS ;
Blake, GJ ;
Ohno-Machado, L ;
Selwyn, AP ;
Popma, JJ ;
Rogers, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (05) :493-496
[4]   Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions [J].
Rickli, H ;
Unterweger, M ;
Sütsch, G ;
Brunner-La Rocca, HP ;
Sagmeister, M ;
Ammann, P ;
Amann, FW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (03) :297-302
[5]   Use of suture-mediated vascular closure devices for the management of femoral vein access after transcatheter procedures [J].
Shaw, JA ;
Dewire, E ;
Nugent, A ;
Eisenhauer, AC .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) :439-443