Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions

被引:13
|
作者
Hyytia, Heidi [1 ]
Heikkila, Taina [1 ]
Hedberg, Pirjo [2 ,3 ]
Puolakanaho, Tarja [2 ,3 ]
Pettersson, Kim [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
[2] Oulu Univ Hosp, NordLab Oulu, Oulu, Finland
[3] Univ Oulu, Dept Clin Chem, Oulu, Finland
关键词
Troponin I; Immunoassay; Cross-reactivity; HIGH-SENSITIVITY TROPONIN; IMMUNOASSAY; SPECIFICITY; DIAGNOSIS; SERUM; FRAGMENTS; MUSCLE;
D O I
10.1016/j.clinbiochem.2014.12.028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To study the skeletal troponin I (skTnI) cross-reactivity of four different commercially available antibodies in four cardiac troponin I (cTnI) research assay versions having the same epitope specificity as evidenced by peptide mapping. Design and methods: The four research assays all use two solid phase antibodies and one detection antibody attached to intrinsically fluorescent nanoparticles.Two alternative antibodies were used for one capture antibody and two for the detector antibody. The assays were evaluated in terms of analytical sensitivity and by determining assay cross-reactivity to skTnI. Additionally, regression analysis was performed by measuring a sample panel (n = 101) with all of the four assay versions. Results: A false positive cTnI concentration of >7000 ng/L was measured with one of the assay versions, when serum was spiked with 500,000 ng/L skTnI. The corresponding observed cTnI values for the other three assay versions varied from 616 ng/L to 727 ng/L. Out of the 101 clinical samples assayed, five showed spuriously (3- to 148 fold) elevated cTnI values with the skTnI interference prone assay setup, but not with the other assay versions. According to our investigational skTnI assay, all five samples contained measurable amounts of skTnI (range: 5500-702,000 ng/L). Conclusions: Two out of four cTnI antibodies tested cross-reacted vastly with skTnI but did not cause any notable interference unless paired together. Therefore, skTnI cross reactivity should be carefully assessed when cTnI assay antibodies claimed to be cTnI specific are selected. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 50 条
  • [21] Chimeric recombinant antibody fragments in cardiac troponin I immunoassay
    Hyytia, Heidi
    Heikkila, Taina
    Brockmann, Eeva-Christine
    Kekki, Henna
    Hedberg, Pirjo
    Puolakanaho, Tarja
    Lovgren, Timo
    Pettersson, Kim
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 347 - 352
  • [22] Biochemical and immunological properties of human cardiac troponin I fragments
    Morjana, N
    Clark, D
    Tal, R
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2001, 33 (02) : 107 - 115
  • [23] Elevation of Cardiac Troponin T, But Not Cardiac Troponin I, in Patients With Neuromuscular Diseases
    Rittoo, Dylmitr
    Jones, Alan
    Lecky, Bryan
    Neithercut, Duncan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (22) : 2411 - 2420
  • [24] Diagnostic Validation of a High-Sensitivity Cardiac Troponin I Assay
    Soerensen, Nils A.
    Gossling, Alina
    Neumann, Johannes T.
    Hartikainen, Tau S.
    Haller, Paul M.
    Scharlemann, Lea
    Lehmacher, Jonas
    Ziegler, Andreas
    Blankenberg, Stefan
    Zeller, Tanja
    Nordholt, Gerhard
    Renne, Thomas
    Westermann, Dirk
    CLINICAL CHEMISTRY, 2021, 67 (09) : 1230 - 1239
  • [25] Antigenic definition of cardiac troponin I
    Larue, C
    Ferrieres, G
    Laprade, M
    Calzolari, C
    Granier, C
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (06) : 361 - 365
  • [26] Cardiac Troponin I in Racing Standardbreds
    Slack, J.
    Boston, R. C.
    Soma, L.
    Reef, V. B.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2012, 26 (05) : 1202 - 1208
  • [27] Spiegelmer-Based Sandwich Assay for Cardiac Troponin I Detection
    Tolnai, Zoltan Janos
    Andras, Judit
    Szeitner, Zsuzsanna
    Percze, Krisztina
    Simon, Laszlo Ferenc
    Gyurcsanyi, Robert E.
    Meszaros, Tamas
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (14) : 1 - 11
  • [28] A signal amplifying fluorescent nanoprobe and lateral flow assay for ultrasensitive detection of cardiac biomarker troponin I
    Lou, Doudou
    Fan, Lin
    Ji, Yongxin
    Gu, Ning
    Zhang, Yu
    ANALYTICAL METHODS, 2019, 11 (28) : 3506 - 3513
  • [29] Development of a paper microfluidic surface enhanced Raman scattering assay for cardiac troponin I
    Tu, Dandan
    Dean, John
    Holderby, Allison
    Schechinger, Monika
    Cote, Gerard L.
    OPTICAL DIAGNOSTICS AND SENSING XX: TOWARD POINT-OF-CARE DIAGNOSTICS, 2020, 11247
  • [30] Evaluation of a New Skeletal Troponin I Assay in Patients with Idiopathic Inflammatory Myopathies
    Bamberg, Katriina
    Mehtala, Laura
    Arola, Olli
    Laitinen, Seppo
    Nordling, Pauliina
    Strandberg, Marjatta
    Strandberg, Niko
    Paltta, Johanna
    Mali, Markku
    Espinosa-Ortega, Fabricio
    Pirila, Laura
    Lundberg, Ingrid E.
    Savukoski, Tanja
    Pettersson, Kim
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2020, 5 (02) : 320 - 331