Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions

被引:13
|
作者
Hyytia, Heidi [1 ]
Heikkila, Taina [1 ]
Hedberg, Pirjo [2 ,3 ]
Puolakanaho, Tarja [2 ,3 ]
Pettersson, Kim [1 ]
机构
[1] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
[2] Oulu Univ Hosp, NordLab Oulu, Oulu, Finland
[3] Univ Oulu, Dept Clin Chem, Oulu, Finland
关键词
Troponin I; Immunoassay; Cross-reactivity; HIGH-SENSITIVITY TROPONIN; IMMUNOASSAY; SPECIFICITY; DIAGNOSIS; SERUM; FRAGMENTS; MUSCLE;
D O I
10.1016/j.clinbiochem.2014.12.028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To study the skeletal troponin I (skTnI) cross-reactivity of four different commercially available antibodies in four cardiac troponin I (cTnI) research assay versions having the same epitope specificity as evidenced by peptide mapping. Design and methods: The four research assays all use two solid phase antibodies and one detection antibody attached to intrinsically fluorescent nanoparticles.Two alternative antibodies were used for one capture antibody and two for the detector antibody. The assays were evaluated in terms of analytical sensitivity and by determining assay cross-reactivity to skTnI. Additionally, regression analysis was performed by measuring a sample panel (n = 101) with all of the four assay versions. Results: A false positive cTnI concentration of >7000 ng/L was measured with one of the assay versions, when serum was spiked with 500,000 ng/L skTnI. The corresponding observed cTnI values for the other three assay versions varied from 616 ng/L to 727 ng/L. Out of the 101 clinical samples assayed, five showed spuriously (3- to 148 fold) elevated cTnI values with the skTnI interference prone assay setup, but not with the other assay versions. According to our investigational skTnI assay, all five samples contained measurable amounts of skTnI (range: 5500-702,000 ng/L). Conclusions: Two out of four cTnI antibodies tested cross-reacted vastly with skTnI but did not cause any notable interference unless paired together. Therefore, skTnI cross reactivity should be carefully assessed when cTnI assay antibodies claimed to be cTnI specific are selected. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 50 条
  • [1] Evaluation of a high-sensitivity cardiac troponin I assay compared to a first-generation cardiac troponin I assay in Doberman Pinschers with and without dilated cardiomyopathy
    Klueser, Lena
    Maier, Elizabeth T.
    Wess, Gerhard
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2019, 33 (01) : 54 - 63
  • [2] Troponin-Specific Autoantibody Interference in Different Cardiac Troponin I Assay Configurations
    Savukoski, Tanja
    Engstrom, Emilia
    Engblom, Janne
    Ristiniemi, Noora
    Wittfooth, Saara
    Lindahl, Bertil
    Eggers, Kai M.
    Venge, Per
    Pettersson, Kim
    CLINICAL CHEMISTRY, 2012, 58 (06) : 1040 - 1048
  • [3] Elevated Cardiac Troponin T in Skeletal Myopathies Skeletal TnT Cross-Reactivity and/or Cardiac TnT Expression?
    Vroemen, Wim H. M.
    de Boer, Douwe
    Streng, Alexander S.
    Mingels, Alma M. A.
    Meex, Steven J. R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (03) : 347 - 349
  • [4] Analytical evaluation of an automated immunoassay for cardiac troponin I: The Vidas Troponin I assay
    Di Serio, F
    Trerotoli, P
    Serio, G
    Varraso, L
    Pansini, N
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (10) : 1363 - 1368
  • [5] Analytical validation of a conventional cardiac troponin I assay for dogs and cats
    Langhorn, Rebecca
    Yrfelt, Jacob D.
    Stjernegaard, Claus S.
    Christiansen, Liselotte B.
    Olsen, Lisbeth H.
    Nielsen, Lise N.
    VETERINARY CLINICAL PATHOLOGY, 2019, 48 (01) : 36 - 41
  • [6] Evaluation of a new ultrasensitive assay for cardiac troponin I
    Casals, Gregori
    Filella, Xavier
    Bedini, Josep Lluis
    CLINICAL BIOCHEMISTRY, 2007, 40 (18) : 1406 - 1413
  • [7] Troponin I as a prognostic marker of cardiac events in asymptomatic hemodialysis patients using a sensitive troponin I assay
    Meghana R. Gaiki
    Maria V. DeVita
    Michael F. Michelis
    Georgia Panagopoulos
    Jordan L. Rosenstock
    International Urology and Nephrology, 2012, 44 : 1841 - 1845
  • [8] Troponin I as a prognostic marker of cardiac events in asymptomatic hemodialysis patients using a sensitive troponin I assay
    Gaiki, Meghana R.
    DeVita, Maria V.
    Michelis, Michael F.
    Panagopoulos, Georgia
    Rosenstock, Jordan L.
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2012, 44 (06) : 1841 - 1845
  • [10] Novel sensitive cardiac troponin I immunoassay free from troponin I-specific autoantibody interference
    Savukoski, Tanja
    Jacobino, Jenna
    Laitinen, Paivi
    Lindahl, Bertil
    Venge, Per
    Ristiniemi, Noora
    Wittfooth, Saara
    Pettersson, Kim
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (07) : 1041 - 1048