Medical X-ray tube

被引:0
|
作者
Taubin, M. [1 ]
Yaskolko, A. [1 ]
机构
[1] FSUE SRI SIA Lutch, Podolsk, Russia
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING | 2009年 / 25卷
关键词
X-ray; tube; monocrystalline; cathode; anod;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray tube test data are shown in this paper and proposals of cerametallic X-ray tube properties improving are made. Particularly, advantages of using monocrystalline anode and monocrystalline flat emitter are presented. During first 1000 cycles dosage rate of X-ray tube with monocrystalline anode reducing for (10+12)%. Then dose reducing rate become stable near (0,7+1,0)% per 1000 cycles. X-ray tube with polyocrystalline anode has more significant reducing during first 4000 cycles. Modern mammography X-ray tubes require small electron focal spot. Traditional coil emitter made of tungsten filament dont satisfy this requirements. Thus most perspective emitter for mammography X-ray tubes is emitter with plane emitting surface. In addition tungsten emitter with single-crystal structure has less working temperature due to its smaller work function ([111] crystallographic plane of tungsten has work function about 4,4 eV, while polycrystalline tungsten - 4,55 eV). Working temperature difference of this materials is about 70 degrees C.
引用
收藏
页码:722 / 724
页数:3
相关论文
共 50 条
  • [31] A high-performance X-ray system for medical device irradiation
    Stichelbaut, F.
    Bol, J.-L.
    Cleland, M. R.
    Herer, A. S.
    Hubeau, J. P.
    Mullier, B.
    RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (11-12) : 1775 - 1778
  • [32] Toward practical coherent X-ray sources: Potential medical applications
    Waynant, RW
    Ilev, IK
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2000, 6 (06) : 1465 - 1469
  • [33] Automatic classification of medical X-ray images with convolutional neural networks
    Nkwentsha, Xolisani
    Hounkanrin, Anicet
    Nicolls, Fred
    2020 INTERNATIONAL SAUPEC/ROBMECH/PRASA CONFERENCE, 2020, : 814 - 817
  • [34] Bio-medical X-ray imaging with spectroscopic pixel detectors
    Butler, A. P. H.
    Anderson, N. G.
    Tipples, R.
    Cook, N.
    Watts, R.
    Meyer, J.
    Bell, A. J.
    Melzer, T. R.
    Butler, P. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) : 141 - 146
  • [35] Characterization of X-ray Detectors in the MIT X-ray Polarimetry Beamline
    Heine, Sarah N. T.
    Marshall, Herman L.
    Schneider, Benjamin
    LaMarr, Beverly
    Kothnur, Nithya
    Garner, Alan
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103
  • [36] Prototype of the high sensitive X-ray microcalorimeter for X-ray imaging
    Kudo, H
    Nakamura, T
    Arakawa, T
    Ohtsuka, S
    Izumi, T
    Shoji, S
    Sato, H
    Kobayashi, H
    Mori, K
    Homma, T
    Osaka, T
    Mitsuda, K
    Yamasaki, NY
    Fujimoto, R
    Iyomoto, N
    Oshima, T
    Futamoto, K
    Takei, Y
    Ichitsubo, T
    Fujimori, T
    Ishisaki, Y
    Morita, U
    Koga, T
    Sato, K
    Ohashi, T
    Kuroda, Y
    Onishi, M
    Otake, K
    Beppu, F
    SENSORS AND ACTUATORS A-PHYSICAL, 2004, 114 (2-3) : 171 - 175
  • [37] A natural explanation for periodic X-ray outbursts in Be/X-ray binaries
    Okazaki, AT
    Negueruela, I
    ASTRONOMY & ASTROPHYSICS, 2001, 377 (01): : 161 - 174
  • [38] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [39] X-ray resonator on the basis of superradiant parametric X-ray emission
    San, N. Q.
    Ulyanenkov, O. D. Skoromnik A. P.
    Feranchuk, I. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 551
  • [40] X-Ray Holography
    Gyula Faigel
    Miklós Tegze
    Structural Chemistry, 2003, 14 : 15 - 21