Experimental studies on simultaneous removal of CO2 and SO2 in a polypropylene hollow fiber membrane contactor

被引:131
|
作者
Lv, Yuexia [1 ,2 ]
Yu, Xinhai [1 ]
Tu, Shan-Tung [1 ]
Yan, Jinyue [2 ,3 ]
Dahlquist, Erik [2 ]
机构
[1] E China Univ Sci & Technol, Key Lab Pressure Syst & Safety, Minist Educ, Sch Mech & Power Engn, Shanghai 200237, Peoples R China
[2] Malardalen Univ, Sch Sustainable Dev Soc & Technol, Vasteras, Sweden
[3] Royal Inst Technol, Sch Chem Sci & Engn, Stockholm, Sweden
关键词
Simultaneous absorption; CO2; capture; SO2; removal; Membrane contactor; Partial wetting; CARBON-DIOXIDE; FLUE-GAS; SIMULTANEOUS ABSORPTION; HYDROGEN-SULFIDE; SULFUR-DIOXIDE; SEPARATION; CAPTURE; STREAMS; H2S; PERFORMANCE;
D O I
10.1016/j.apenergy.2012.01.034
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Membrane gas absorption technology is a promising alternative to conventional technologies for the mitigation of acid gases. In this study, simultaneous removal of SO2 and CO2 from coal-fired flue gas was carried out in a polypropylene hollow fiber membrane contactor using aqueous monoethanolamine as the absorbent. The influences of liquid and gas flow rates on the simultaneous absorption performance of CO2 and SO2 were investigated. The experimental results indicated that the membrane contactor could eliminate these two sour gases simultaneously and effectively. Absorption of SO2 and CO2 was enhanced by the increase in liquid flow rate and decrease in gas flow rate. It was observed that a small amount of SO2 in the flue gas had a slight influence on the absorption of CO2. In addition, the membrane contactor was operated continuously for two weeks to evaluate its duration performance. The results showed that the CO2 mass transfer rate was decreased significantly with the operating time due to partial wetting of membrane pores. After 14 days of continuous operation, the CO2 mass transfer rate of the wetted membrane contactor was decreased by 41% but could be retrieved to 86% of the fresh one by increasing the gas phase pressure. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 50 条
  • [21] Experimental and theoretical analyses of effects of membrane properties on CO2 absorption performance of a hollow fiber membrane contactor
    Takahashi, Nobuhide
    Mano, Hiroshi
    Okabe, Kazuhiro
    Nakamura, Miho
    Fujioka, Yuichi
    Mimura, Tomio
    Yagi, Yasuyuki
    KAGAKU KOGAKU RONBUNSHU, 2008, 34 (01) : 76 - 84
  • [22] CO2 REMOVAL BY HOLLOW-FIBER GAS-LIQUID CONTACTOR
    NISHIKAWA, N
    ISHIBASHI, M
    OHTA, H
    AKUTSU, N
    MATSUMOTO, H
    KAMATA, T
    KITAMURA, H
    ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (6-9) : 415 - 418
  • [23] A Numerical Study on Removal of CO2 by 2-(tert-Butylamino) Ethanol in a Hollow Fiber Membrane Contactor
    Ao, Di
    Ma, Guiyang
    Zang, Chunyang
    Qin, Yue
    Qi, Yu
    Wan, Wenfei
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2022, 61 (10) : 3685 - 3693
  • [24] The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
    Hashemifard, S. A.
    Ahmadi, H.
    Ismail, A. F.
    Moarefian, Ahmad
    Abdullah, M. S.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 223 : 186 - 195
  • [25] CO2 absorption at elevated pressures using a hollow fiber membrane contactor
    Dindore, VY
    Brilman, DWF
    Feron, PHM
    Versteeg, GF
    JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) : 99 - 109
  • [26] Development of asymmetric polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 86 : 215 - 220
  • [27] Hollow fiber membrane process for SO2 removal from flue gas
    Kim, KeeHong
    Kim, JongHak
    Lee, HyungKeun
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (03) : 423 - 431
  • [28] Modeling and simulation of CO2 removal in a polyvinylidene fluoride hollow fiber membrane contactor with computational fluid dynamics
    Farjami, Marzie
    Moghadassi, Abdolreza
    Vatanpour, Vahid
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2015, 98 : 41 - 51
  • [29] Biocatalytic PVDF composite hollow fiber membranes for CO2 removal in gas-liquid membrane contactor
    Xu, Yilin
    Lin, Yuqing
    Chew, Nick Guan Pin
    Malde, Chandresh
    Wang, Rong
    JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 532 - 544
  • [30] CO2 Capture and H2 Recovery Using a Hollow Fiber Membrane Contactor
    Jeong, Cheonwoo
    Pandey, Sadanand
    Lee, Dongcheol
    Park, SangHyeon
    Baik, Joon Hyun
    Kim, Joonwoo
    SEPARATIONS, 2023, 10 (07)