Non-invasive near-infrared spectroscopy assessment of the spinal neurovascular response in a patient with transverse myelitis: a case report

被引:1
|
作者
Esteban Oyarzun, Juan [1 ]
Caulier-Cisterna, Raul [1 ,2 ]
Pablo Gonzalez-Appelgren, Juan [1 ]
Gonzalez, Leticia [1 ]
Trujillo, Oscar [3 ]
Eblen-Zajjur, Antonio [4 ]
Uribe, Sergio [1 ,5 ]
机构
[1] Pontificia Univ Catolica Chile, Ctr Imagenes Biomed, Santiago, Chile
[2] Rielo Inst Integral Dev, New York, NY USA
[3] Pontificia Univ Catolica Chile, Sch Med, Neurol Dept, Santiago, Chile
[4] Univ Diego Portales Santiago, Lab Neurociencia Traslac, Fac Med, Santiago, Chile
[5] Pontificia Univ Catolica Chile, Sch Med, Radiol Dept, Santiago, Chile
关键词
Near infrared spectroscopy (NIRS); Spinal neurovascular response; Non-invasive method; Transverse myelitis; Spinal neuronal activity; Neuron-vascular coupling;
D O I
10.1186/s12883-022-02881-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Transverse myelitis (TM) is characterized by acute development of motor, sensory and autonomic dysfunctions due to horizontally diffused inflammation in one or more segments of the spinal cord in the absence of a compressive lesion. The not well-known inflammation process induces demyelination resulting in neurological dysfunction. Case presentation In this case report we used a functional Near-Infrared Spectroscopy (fNIRS) technique to evaluate changes in the peri-spinal vascular response induced by a peripheral median nerve electrical stimulation in a patient with chronic transverse myelitis (TM). fNIRS showed drastically reduced signal amplitude in the peri-spinal vascular response, compared to that obtained from a healthy control group throughout most of the C7-T1 and T10-L2 spinal cord segments. Conclusion The potential use of this relatively non-invasive fNIRS technology support the potential clinical application of this method for functional test of the spinal cord through the assessment of the spinal neurovascular response.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Non-invasive Self Monitoring of Blood Glucose System Using Near-infrared Spectroscopy
    Yoshinari, Hiroki
    Ishizawa, Hiroaki
    Fukuda, Masaya
    Tokutake, Shota
    Koyama, Shouhei
    Miyauchi, Yuki
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 1852 - 1854
  • [43] A non-invasive dual-channel oximeter based on near-infrared spectroscopy (NIRS)
    Luo, Yuhui
    Tse, Jorden
    Lin, Chinlon
    Chen, Lian-Kuan
    Burd, Andrew
    Huang, Linda
    2007 DIGEST OF THE LEOS SUMMER TOPICAL MEETINGS, 2007, : 139 - +
  • [44] Non-invasive technique to assess hepatic tissue oxygenation using near-infrared spectroscopy
    El-Desoky, A
    Seifalian, AM
    Davidson, BR
    BRITISH JOURNAL OF SURGERY, 1998, 85 (05) : 701 - 701
  • [45] NON-INVASIVE DETERMINATION OF CEREBRAL VENOUS HEMOGLOBIN SATURATION IN THE DOG BY NEAR-INFRARED SPECTROSCOPY
    FERRARI, M
    HARTMANN, JF
    HANLEY, DF
    WILSON, DA
    TRAYSTMAN, RJ
    FASEB JOURNAL, 1988, 2 (04): : A508 - A508
  • [46] A Non-invasive Method for Screening Sodium Hydroxymethanesulfonate in Wheat Flour by Near-Infrared Spectroscopy
    Yuan, Wenbo
    Xiang, Bingren
    Yu, Liyan
    Xu, Jianping
    FOOD ANALYTICAL METHODS, 2011, 4 (04) : 550 - 558
  • [47] Feasibility of non-invasive measurement of tissue pH using near-infrared reflectance spectroscopy
    Center for Advanced Clinical Technology, Worcester, MA 01655, United States
    不详
    不详
    不详
    J. CLIN. MONIT., 5 (387-395):
  • [48] Non-invasive Blood Glucose Estimation using Near-Infrared Spectroscopy based on SVR
    Zhang, Yue
    Wang, Ziliang
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 594 - 598
  • [49] Non-invasive blood glucose sensing on human body with near-infrared reflection spectroscopy
    Huang Zhen-hao
    Hao Chang-ning
    Zhang Lin-lin
    Huang Yan-chao
    Shi Yi-qin
    Jiang Geng-ru
    Duan Jun-li
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS, 2011, 8193
  • [50] Non-invasive spinal cord oxygenation monitoring: validating collateral network near-infrared spectroscopy for thoracoabdominal aortic aneurysm repairaEuro
    von Aspern, Konstantin
    Haunschild, Josephina
    Hoyer, Alexandro
    Luehr, Maximilian
    Bakhtiary, Farhad
    Misfeld, Martin
    Mohr, Friedrich W.
    Etz, Christian D.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (04) : 675 - 683