Electrogram morphology discriminators in implantable cardioverter defibrillators: A comparative evaluation

被引:5
|
作者
Frontera, Antonio [1 ,2 ]
Strik, Marc [1 ,2 ,3 ]
Eschalier, Romain [4 ]
Biffi, Mauro [5 ]
Pereira, Bruno [4 ]
Welte, Nicolas [1 ]
Chauvel, Remi [1 ]
Mondoly, Pierre [6 ]
Laborderie, Julien [7 ]
Bernis, Jean-Paul [7 ]
Clementy, Nicolas [8 ]
Reuter, Sylvain [9 ]
Garrigue, Stephane [9 ]
Deplagne, Antoine [10 ]
Vernooy, Kevin [3 ,11 ]
Pillois, Xavier [1 ,2 ]
Haissaguerre, Michel [1 ,2 ]
Dubois, Remi [2 ]
Ritter, Philippe [1 ,2 ]
Bordachar, Pierre [1 ,2 ]
Ploux, Sylvain [1 ,2 ]
机构
[1] Bordeaux Univ Hosp CHU, Cardio Thorac Unit, Pessac, France
[2] Fondat Bordeaux Univ, Electrophysiol & Heart Modeling Inst, IHU Liryc, Bordeaux, France
[3] Maastricht Univ, Cardiovasc Res Inst Maastricht, Physiol & Cardiol Dept, Med Ctr, Maastricht, Netherlands
[4] Univ Clermont Auvergne, Inst Pascal, Cardiol Dept, CHU Clermont Ferrand, Clermont Ferrand, France
[5] Azienda Osped Univ Bologna, Bologna, Italy
[6] Univ Hosp Rangueil, Toulouse, France
[7] CH Bayonne, Bayonne, France
[8] CHU Tours, Cardiol Dept, Tours, France
[9] St Augustin Clin, Cardiol Dept, Bordeaux, France
[10] Robert Boulin Hosp, Cardiol Dept, Libourne, France
[11] Radboud Univ Nijmegen, Dept Cardiol, Med Ctr, Nijmegen, Netherlands
关键词
algorithm; arrhythmia; discrimination; implantable cardioverter defibrillator; morphology; SUPRAVENTRICULAR TACHYCARDIA; VENTRICULAR-TACHYCARDIA; RHYTHM DISCRIMINATION; DUAL-CHAMBER; ALGORITHM;
D O I
10.1111/jce.14518
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Morphology algorithms are currently recommended as a standalone discriminator in single-chamber implantable cardioverter defibrillators (ICDs). However, these proprietary algorithms differ in both design and nominal programming. Objective To compare three different algorithms with nominal versus advanced programming in their ability to discriminate between ventricular (VT) and supraventricular tachycardia (SVT). Methods In nine European centers, VT and SVTs were collected from Abbott, Boston Scientific, and Medtronic dual- and triple-chamber ICDs via their respective remote monitoring portals. Percentage morphology matches were recorded for selected episodes which were classified as VT or SVT by means of atrioventricular comparison. The sensitivity and related specificity of each manufacturer discriminator was determined at various values of template match percentage from receiving operating characteristics (ROC) curve analysis. Results A total of 534 episodes were retained for the analysis. In ROC analyses, Abbott Far Field MD (area under the curve [AUC]: 0.91; P < .001) and Boston Scientific RhythmID (AUC: 0.95; P < .001) show higher AUC than Medtronic Wavelet (AUC: 0.81; P < .001) when tested for their ability to discriminate VT from SVT. At nominal % match threshold all devices provided high sensitivity in VT identification, (91%, 100%, and 90%, respectively, for Abbott, Boston Scientific, and Medtronic) but contrasted specificities in SVT discrimination (85%, 41%, and 62%, respectively). Abbott and Medtronic's nominal thresholds were similar to the optimal thresholds. Optimization of the % match threshold improved the Boston Scientific specificity to 79% without compromising the sensitivity. Conclusion Proprietary morphology discriminators show important differences in their ability to discriminate SVT. How much this impact the overall discrimination process remains to be investigated.
引用
收藏
页码:1493 / 1506
页数:14
相关论文
共 50 条
  • [1] Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators
    Theuns, Dominic A. M. J.
    Rivero-Ayerza, Maximo
    Goedhart, Dick M.
    van der Perk, Ronald
    Jordaens, Luc J.
    HEART RHYTHM, 2006, 3 (11) : 1332 - 1338
  • [2] Continuous template collection and updating for electrogram morphology discrimination in implantable cardioverter defibrillators
    Compton, SJ
    Merrill, JJ
    Dorian, P
    Cao, J
    Zhou, D
    Gillberg, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (03): : 244 - 254
  • [3] Advanced rhythm discrimination for implantable cardioverter defibrillators using electrogram vector timing and correlation
    Gold, MR
    Shorofsky, SR
    Thompson, JA
    Kim, J
    Schwartz, M
    Bocek, J
    Lovett, EG
    Hsu, W
    Morris, MM
    Lang, DJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (11) : 1092 - 1097
  • [4] Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators
    Bouchet, P.
    Dubois, R.
    Henry, C.
    Roussel, P.
    Dreyfus, G.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 9 - +
  • [5] Implantable Cardioverter Defibrillators in Patients with Cardiac Amyloidosis
    Lin, Grace
    Dispenzieri, Angela
    Kyle, Robert
    Grogan, Martha
    Brady, Peter A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (07) : 793 - 798
  • [6] Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO)
    Toquero, Jorge
    Alzueta, Javier
    Mont, Lluis
    Lozano, Ignacio F.
    Barrera, Alberto
    Berruezo, Antonio
    Castro, Victor
    Luis Pena, Jose
    Luisa Fidalgo, Maria
    Brugada, Josep
    EUROPACE, 2009, 11 (06): : 727 - 733
  • [7] Sensing and Detection Functions in Implantable Cardioverter Defibrillators: The Good, the Bad and the Ugly
    Kossaify, Antoine
    ACTA CARDIOLOGICA SINICA, 2020, 36 (04) : 308 - 317
  • [8] T-Wave Oversensing with Contemporary Implantable Cardioverter-Defibrillators
    Strik, Marc
    Ploux, Sylvain
    Eschalier, Romain
    Mondoly, Pierre
    Fontagne, Leslie
    Ramirez, F. Daniel
    Haissaguerre, Michel
    Bordachar, Pierre
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (10)
  • [9] Atrioventricular Nodal Reentrant Tachycardia in Implantable Cardioverter Defibrillators: Diagnosis and Troubleshooting
    Enriquez, Andres
    Ellenbogen, Kenneth A.
    Boles, Usama
    Baranchuk, Adrian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (11) : 1282 - 1288
  • [10] Fuzzy logic-based diagnostic algorithm for implantable cardioverter defibrillators
    Bardossy, Andras
    Blinowska, Aleksandra
    Kuzmicz, Wieslaw
    Ollitrault, Jacky
    Lewandowski, Michal
    Przybylski, Andrzej
    Jaworski, Zbigniew
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2014, 60 (02) : 113 - 121