Voltage stability improvement of wind power grid-connected system using TCSC-STATCOM control

被引:21
作者
Kuang, Honghai [1 ,2 ]
Zheng, Liping [1 ]
Li, Shengqing [1 ,2 ]
Ding, Xiaowei [1 ]
机构
[1] Hunan Univ Technol, Coll Elect & Informat Engn, Zhuzhou 412007, Peoples R China
[2] Key Lab Elect Dr Control & Intelligent Equipment, Zhuzhou 412007, Peoples R China
基金
湖南省自然科学基金;
关键词
power generation faults; power generation control; voltage control; static VAr compensators; thyristor applications; power grids; wind power plants; closed loop systems; feedback; voltage stability improvement; wind power grid-connected systems; TCSC-STATCOM control; cooperative control scheme; thyristor controlled series compensator; static synchronous compensator; STATCOM double closed-loop feedback control; TCSC device; simulation model; MATLAB; Simulink; bus voltage; grid-connected wind farms; low-voltage ride-through capability;
D O I
10.1049/iet-rpg.2018.5492
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aiming at the voltage stability problem of wind power grid-connected systems, a cooperative control scheme of Thyristor Controlled Series Compensator (TCSC) and Static Synchronous Compensator (STATCOM) is proposed in this study. The proposed scheme is applied in the wind power grid-connected system, a combined control strategy based on STATCOM double closed-loop feedback control and TCSC device is used to ensure that the system has enough reactive power to maintain its normal work during operation. The corresponding simulation model of wind power grid-connected system is built in MATLAB/Simulink. By analysing and comparing the waveforms of the operating examples with only TCSC, only STATCOM and TCSC-STATCOM, it is shown that the cooperative control of TCSC and STATCOM can quickly and effectively recover the bus voltage at the point of grid-connected wind farms after fault, which has a good performance on improving the voltage stability of wind power grid-connected system and increasing the low-voltage ride-through capability, and the cooperative control effect of TCSC and STATCOM is better than only using the control of TCSC or STATCOM.
引用
收藏
页码:215 / 219
页数:5
相关论文
共 27 条
[1]  
[Anonymous], 2007, P 2007 POW SYST C AD, DOI DOI 10.1109/PSAMP.2007.4740923
[2]   Power quality and stability improvement of a wind farm using STATCOM supported with hybrid battery energy storage [J].
Arulampalam, A. ;
Barnes, M. ;
Jenkins, N. ;
Ekanayake, J. B. .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (06) :701-710
[3]  
Bai F., 2011, J DALIAN U TECHNOL, V51, P65
[4]  
Cheng Z.-x., 2013, LAB RES EXPLOR, V32, P76
[5]  
He Q., 2016, Thermoelectr. Power Gener, V45, P34
[6]   Improved low-voltage-ride-through capability of fixed-speed wind turbines using decentralised control of STATCOM with energy storage system [J].
Hossain, M. J. ;
Pota, H. R. ;
Ramos, R. A. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (08) :719-730
[7]  
[黄柳强 Huang Liuqiang], 2012, [电力系统保护与控制, Power System Protection and Control], V40, P138
[8]  
Jalilzadeh S., 2011, IR C EL ENG ICEE IR, P1
[9]  
Ke Ning, 2004, Automation of Electric Power Systems, V28, P20
[10]  
Kuang H., 2015, J POWER SUPPLY, V13