Deformation Capacity of RC Beam-Column Joints Strengthened with Ferrocement

被引:12
作者
Araby, M. Zardan [1 ,2 ]
Rizal, Samsul [3 ]
Abdullah [2 ]
Afifuddin, Mochammad [2 ]
Hasan, Muttaqin [2 ]
机构
[1] Univ Syiah Kuala, Engn Study Program, Darussalam 23111, Banda Aceh, Indonesia
[2] Univ Syiah Kuala, Dept Civil Engn, Darussalam 23111, Banda Aceh, Indonesia
[3] Univ Syiah Kuala, Dept Mech Engn, Darussalam 23111, Banda Aceh, Indonesia
关键词
beam-column joint; ferrocement; crack; ductility; displacement; REINFORCED-CONCRETE FRAME; SEISMIC PERFORMANCE; CYCLIC PERFORMANCE; REHABILITATION; STEEL; BUILDINGS; BEHAVIOR; MICROSTRUCTURE; CANTERBURY; EARTHQUAKE;
D O I
10.3390/su14084398
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Beam-column joints constructed in the pre-seismic building code do not provide transverse reinforcement and good reinforcement detailing within the region. These cause the occurrence of brittle shear failure, which is one of the factors affecting the number of reinforced concrete (RC) moment resistance building structures collapsing during an earthquake. Therefore, in this study a brittle beam-column joint with a non-seismic building code was designed and strengthened by a ferrocement. Four layers of wire mesh with a diameter of 1 mm and a mesh size of 25.4 mm were installed on both sides of the beam-column joint and cement mortar was cast on it. As a comparison, a ductile beam-column joint was also designed following the current building code, which considers seismic effects. The test results by applying reversed cyclic loading at the beam tip showed that strengthening using ferrocement prevents crack propagation, increasing the deformation capacity, ductility, stiffness, and energy dissipation of beam column joint which are higher than those of the beam-column joint which is designed following the current building code. However, the strengthening does not improve the load carrying capacity significantly.
引用
收藏
页数:20
相关论文
共 77 条
[61]  
Raghunathapandian P., 2020, INT J RECENT TECHNOL, V8, P2277
[62]   Cyclic Performance of Beam-Column Subassemblies with Construction Joint in Column Retrofitted with GFRP [J].
Roy, Biswajit ;
Laskar, Aminul Islam .
STRUCTURES, 2018, 14 :290-300
[64]   Performance of reinforced concrete buildings during the August 17, 1999 Kocaeli, Turkey earthquake, and seismic design and construction practise in Turkey [J].
Sezen, H ;
Whittaker, AS ;
Elwood, KJ ;
Mosalam, KM .
ENGINEERING STRUCTURES, 2003, 25 (01) :103-114
[65]   Finite element modeling of exterior beam-column joints strengthened by ferrocement under cyclic loading [J].
Shaaban, Ibrahim G. ;
Said, Mohamed .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2018, 8 :333-346
[66]   Experimental behavior of full-scale exterior beam-column space joints retrofitted by ferrocement layers under cyclic loading [J].
Shaaban, Ibrahim G. ;
Seoud, Osama A. .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2018, 8 :61-78
[67]  
Shakthivel V., 2019, INT J ENG TECH, V5, P186
[68]  
Su N., 2001, PRACT PERIOD STRUCT, V6, P119
[69]   Structural behaviour of CFRP strengthened beam-column connections under monotonic and cyclic loading [J].
Tafsirojjaman, T. ;
Fawzia, Sabrina ;
Thambiratnam, David P. .
STRUCTURES, 2021, 33 :2689-2699
[70]  
TAKIGUCHI K., 2003, CEMENT CONCRETE COMP, V25, P233