Deformation Capacity of RC Beam-Column Joints Strengthened with Ferrocement

被引:12
作者
Araby, M. Zardan [1 ,2 ]
Rizal, Samsul [3 ]
Abdullah [2 ]
Afifuddin, Mochammad [2 ]
Hasan, Muttaqin [2 ]
机构
[1] Univ Syiah Kuala, Engn Study Program, Darussalam 23111, Banda Aceh, Indonesia
[2] Univ Syiah Kuala, Dept Civil Engn, Darussalam 23111, Banda Aceh, Indonesia
[3] Univ Syiah Kuala, Dept Mech Engn, Darussalam 23111, Banda Aceh, Indonesia
关键词
beam-column joint; ferrocement; crack; ductility; displacement; REINFORCED-CONCRETE FRAME; SEISMIC PERFORMANCE; CYCLIC PERFORMANCE; REHABILITATION; STEEL; BUILDINGS; BEHAVIOR; MICROSTRUCTURE; CANTERBURY; EARTHQUAKE;
D O I
10.3390/su14084398
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Beam-column joints constructed in the pre-seismic building code do not provide transverse reinforcement and good reinforcement detailing within the region. These cause the occurrence of brittle shear failure, which is one of the factors affecting the number of reinforced concrete (RC) moment resistance building structures collapsing during an earthquake. Therefore, in this study a brittle beam-column joint with a non-seismic building code was designed and strengthened by a ferrocement. Four layers of wire mesh with a diameter of 1 mm and a mesh size of 25.4 mm were installed on both sides of the beam-column joint and cement mortar was cast on it. As a comparison, a ductile beam-column joint was also designed following the current building code, which considers seismic effects. The test results by applying reversed cyclic loading at the beam tip showed that strengthening using ferrocement prevents crack propagation, increasing the deformation capacity, ductility, stiffness, and energy dissipation of beam column joint which are higher than those of the beam-column joint which is designed following the current building code. However, the strengthening does not improve the load carrying capacity significantly.
引用
收藏
页数:20
相关论文
共 77 条
[31]   Seismic Performance of Exterior RC Beam-Column Joints Retrofitted using Various Retrofit Solutions [J].
Gia Toai Truong ;
Ngoc Hieu Dinh ;
Kim, Jong-Chan ;
Choi, Kyoung-Kyu .
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2017, 11 (03) :415-433
[32]   Seismic upgrading of existing reinforced concrete buildings: A state-of-the-art review [J].
Gkournelos, P. D. ;
Triantafillou, T. C. ;
Bournas, D. A. .
ENGINEERING STRUCTURES, 2021, 240
[33]   Seismic Strengthening of Beam-Column Joints with Steel Bars [J].
Gokdemir, Hande ;
Tankut, Tugrul .
TEKNIK DERGI, 2017, 28 (03) :7977-7992
[34]   The assessment and strengthening proposal of building structure after the Pidie Jaya earthquake in December 2016 [J].
Hasan M. ;
Saidi T. ;
Afifuddin M. ;
Setiawan B. .
Journal of King Saud University - Engineering Sciences, 2023, 35 (01) :12-23
[35]  
Jiang Long Min, 2011, Advanced Materials Research, V243-249, P1409, DOI 10.4028/www.scientific.net/AMR.243-249.1409
[36]   Damages to RC school buildings and lessons from the 2011 East Japan earthquake [J].
Kabeyasawa, Toshimi .
BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (02) :535-553
[37]   Ferrocement composites for strengthening of concrete columns: A review [J].
Kaish, A. B. M. A. ;
Jamil, M. ;
Raman, S. N. ;
Zain, M. F. M. ;
Nahar, Lutfun .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 160 :326-340
[38]   Seismic Retrofit of R/C T-Beams with Steel Fiber Polymers under Cyclic Loading Conditions [J].
Katakalos, Konstantinos ;
Manos, George ;
Papakonstantinou, Christos .
BUILDINGS, 2019, 9 (04)
[39]  
Khan SU, 2013, IJST-T CIV ENG, V37, P353
[40]   Effects of Ferrocement in strengthening the Serviceability properties of Reinforced Concrete Structures [J].
Khan, S. U. ;
Nuruddin, M. F. ;
Ayub, T. ;
Shafiq, N. .
MATERIAL DESIGN, PROCESSING AND APPLICATIONS, PARTS 1-4, 2013, 690-693 :686-690