On-line spectrophotometric determination of ferrous and total iron in monominerals by flow injection combined with a Schlenk line-based digestion apparatus to exclude oxygen

被引:6
作者
Xue, Ding-Shuai [1 ,2 ,3 ]
Chen, Guo-Ju [4 ]
Su, Ben-Xun [1 ]
Liu, Yan-Hong [1 ]
Zhang, Dan-Ping [1 ]
Guo, Qian [1 ]
Guo, Ju-Jie [1 ]
Sun, Jie-Fang [5 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, POB 9825, Beijing 100029, Peoples R China
[2] Chinese Acad Sci, Innovat Acad Earth Sci, Beijing 100029, Peoples R China
[3] Univ Chinese Acad Sci, Coll Earth & Planetary Sci, Beijing, Peoples R China
[4] State Key Lab Comprehens Utilizat Nickel & Cobalt, Jinchang 737100, Gansu, Peoples R China
[5] Beijing Ctr Dis Prevent & Control, Beijing Key Lab Diagnost & Traceabil Technol Food, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
On-line photochemical method; Ferrous iron; Total iron; Monomineral; Flow injection; Schlenk line; SILICATE ROCKS; TRACE-ELEMENTS; FERRIC IRON; FE(II); SPECIATION; SOILS; 1,10-PHENANTHROLINE; EXTRACTION; MINERALS;
D O I
10.1016/j.microc.2020.104743
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line photochemical method for measuring the ferrous iron [Fe(II)] and total iron [Fe(T)] contents in monominerals is described herein. A special digestion apparatus connected with a Schlenk line was designed to exclude oxygen during sample digestion. Subsequently, a spectrophotometric flow injection analysis (FIA) system was employed to automate the determination. As a result, a facile, reliable, and accurate analytical procedure was obtained, and both the sample and reagent consumption were reduced compared with traditional spectrophotometric procedures. In addition, the concentrations of the reductant and the chromogenic agent were optimized along with the sample leaching conditions (e.g., the amounts of H2SO4 and HF). Furthermore, the method precision was assessed by comparing the obtained results with those of four geological reference materials (relative standard deviation (RSD) for Fe(II) <2.30%, RSD for Fe(T) <1.75%). Finally, the accuracy of the method was assessed for four monomineral samples using the standard addition method, with recovery percentages of 95.74-104.69% and 95.07-104.56% being obtained for Fe(II) and Fe(T), respectively.
引用
收藏
页数:7
相关论文
共 50 条
[31]   On-line dilution flow injection manifold for the selective spectrophotometric determination of ascorbic acid based on the Fe(II)-2,2′-dipyridyl-2-pyridylhydrazone complex formation [J].
Themelis, DG ;
Tzanavaras, PD ;
Kika, FS .
TALANTA, 2001, 55 (01) :127-134
[32]   Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry [J].
Sigrist, Mirna ;
Albertengo, Antonela ;
Beldomenico, Horacio ;
Tudino, Mabel .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 188 (1-3) :311-318
[33]   Determination of total and inorganic mercury in biological and environmental samples with on-line oxidation coupled to flow injection-cold vapor atomic absorption spectrometry [J].
Río-Segade, S ;
Bendicho, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) :1129-1139
[34]   Determination of pipemidic acid based on flow-injection chemiluminescence due to energy transfer from peroxynitrous acid synthesized on-line [J].
Yao-Dong Liang ;
Jun-Feng Song ;
Tian Tian .
Analytical and Bioanalytical Chemistry, 2004, 380 :918-923
[35]   Determination of pipemidic acid based on flow-injection chemiluminescence due to energy transfer from peroxynitrous acid synthesized on-line [J].
Liang, YD ;
Song, JF ;
Tian, T .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (7-8) :918-923
[36]   On-line Flow-injection Liquid-phase Microextraction and Spectrophotometric Determination of Traces of Copper(II) with Trithia-9-crown-3 as Complexing Agent [J].
Mir Mahdi Zahedi ;
Mojtaba Shamsipur ;
Seied Mahdi Pourmortazavi .
Analytical Sciences, 2013, 29 :1055-1059
[37]   On-line Flow-injection Liquid-phase Microextraction and Spectrophotometric Determination of Traces of Copper(II) with Trithia-9-crown-3 as Complexing Agent [J].
Zahedi, Mir Mahdi ;
Shamsipur, Mojtaba ;
Pourmortazavi, Seied Mahdi .
ANALYTICAL SCIENCES, 2013, 29 (11) :1055-1059
[38]   Continuous on-line concentration based on dynamic pH junction for trimethoprim and sulfamethoxazole by microfluidic capillary electrophoresis combined with flow injection analysis system [J].
Fan, LY ;
Liu, LH ;
Chen, HL ;
Chen, XG ;
Hu, ZD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (01) :133-137
[39]   Double hydride generation gaseous phase enrichment with flow injection on-line automatic preparation for ultratrace amounts of total selenium determination by atomic fluorescence spectrometry [J].
Guo, XM ;
Li, SP ;
Huang, BL .
SPECTROSCOPY LETTERS, 2005, 38 (02) :131-143
[40]   A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine [J].
Gallignani, M ;
Bahsas, H ;
Brunetto, MR ;
Burguera, M ;
Burguera, JL ;
de Peña, YP .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :57-67