On-line spectrophotometric determination of ferrous and total iron in monominerals by flow injection combined with a Schlenk line-based digestion apparatus to exclude oxygen

被引:6
作者
Xue, Ding-Shuai [1 ,2 ,3 ]
Chen, Guo-Ju [4 ]
Su, Ben-Xun [1 ]
Liu, Yan-Hong [1 ]
Zhang, Dan-Ping [1 ]
Guo, Qian [1 ]
Guo, Ju-Jie [1 ]
Sun, Jie-Fang [5 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, POB 9825, Beijing 100029, Peoples R China
[2] Chinese Acad Sci, Innovat Acad Earth Sci, Beijing 100029, Peoples R China
[3] Univ Chinese Acad Sci, Coll Earth & Planetary Sci, Beijing, Peoples R China
[4] State Key Lab Comprehens Utilizat Nickel & Cobalt, Jinchang 737100, Gansu, Peoples R China
[5] Beijing Ctr Dis Prevent & Control, Beijing Key Lab Diagnost & Traceabil Technol Food, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
On-line photochemical method; Ferrous iron; Total iron; Monomineral; Flow injection; Schlenk line; SILICATE ROCKS; TRACE-ELEMENTS; FERRIC IRON; FE(II); SPECIATION; SOILS; 1,10-PHENANTHROLINE; EXTRACTION; MINERALS;
D O I
10.1016/j.microc.2020.104743
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line photochemical method for measuring the ferrous iron [Fe(II)] and total iron [Fe(T)] contents in monominerals is described herein. A special digestion apparatus connected with a Schlenk line was designed to exclude oxygen during sample digestion. Subsequently, a spectrophotometric flow injection analysis (FIA) system was employed to automate the determination. As a result, a facile, reliable, and accurate analytical procedure was obtained, and both the sample and reagent consumption were reduced compared with traditional spectrophotometric procedures. In addition, the concentrations of the reductant and the chromogenic agent were optimized along with the sample leaching conditions (e.g., the amounts of H2SO4 and HF). Furthermore, the method precision was assessed by comparing the obtained results with those of four geological reference materials (relative standard deviation (RSD) for Fe(II) <2.30%, RSD for Fe(T) <1.75%). Finally, the accuracy of the method was assessed for four monomineral samples using the standard addition method, with recovery percentages of 95.74-104.69% and 95.07-104.56% being obtained for Fe(II) and Fe(T), respectively.
引用
收藏
页数:7
相关论文
共 50 条
[21]   Determination of L-phenylalanine on-line based on molecularly imprinted polymeric microspheres and flow injection chemiluminescence [J].
Qiu, Huamin ;
Xi, Yulei ;
Lu, Fuguang ;
Fan, Lulu ;
Luo, Chuannan .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 86 :456-460
[22]   Determination of trace metals in urine with an on-line ultrasound-assisted digestion system combined with a flow-injection preconcentration manifold coupled to flame atomic absorption spectrometry [J].
Cespon-Romero, R. M. ;
Yebra-Biurrun, M. C. .
ANALYTICA CHIMICA ACTA, 2008, 609 (02) :184-191
[23]   Spectrophotometric Determination of Ultra trace Tri & Hexavalent Chromium by Using on-line Flow Injection Analysis with Dual Pre-concentration Column [J].
Jung, Sung-woon ;
Lim, Hyun-woo ;
Kang, Chul-ho ;
Choi, Yong-wook .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (09) :3437-3442
[24]   Determination of trace amounts of cadmium in a hydrometallurgical zinc refining process stream by a flow-injection method with on-line preconcentration and spectrophotometric detection [J].
Hayashibe, Y ;
Sayama, Y .
ANALYST, 1996, 121 (01) :7-11
[25]   Flow injection spectrophotometric determination of V(V) involving on-line separation using a poly(vinylidene fluoride-co-hexafluoropropylene)-based polymer inclusion membrane [J].
Yaftian, Mohammad Reza ;
Almeida, M. Ines G. S. ;
Cattrall, Robert W. ;
Kolev, Spas D. .
TALANTA, 2018, 181 :385-391
[26]   Determination of Cd in sediment samples by flow injection on-line anion exchange combined with vapour generation-atomic fluorescence spectrometry [J].
Wang Yi-Zhuang ;
Qiu Hai-ou ;
Tang Zhi-Yong ;
Gu Yan-sheng ;
Zhang Shu-qing .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (12) :2581-2584
[27]   Ultrasound-Assisted Digestion Using Flow Injection/Stopped-Flow Manifold and On-line Preconcentration for Urinary Nickel Determination by Flame Atomic Absorption Spectrometry [J].
Yebra, M. C. ;
Cespon, R. M. .
ATOMIC SPECTROSCOPY, 2009, 30 (02) :41-46
[28]   Determination of phenol at ng I-1 level by flow-injection chemiluminescence combined with on-line solid-phase extraction [J].
Qi, Huili ;
Lv, Jiagen ;
Li, Baoxin .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (4-5) :874-878
[29]   Flow injection spectrophotometric determination of paracetamol in pharmaceuticals by means of on-line microwave-assisted hydrolysis and reaction with 8-hydroxyquinoline (8-quinolinol) [J].
Bouhsain, Z ;
Garrigues, S ;
MoralesRubio, A ;
delaGuardia, M .
ANALYTICA CHIMICA ACTA, 1996, 330 (01) :59-69
[30]   On-line collection/concentration of trace amounts of formaldehyde in air with chromatomembrane cell and its sensitive determination by flow injection technique coupled with spectrophotometric and fluorometric detection [J].
Sritharathikhun, P ;
Oshima, M ;
Motomizu, S .
TALANTA, 2005, 67 (05) :1014-1022