On-line spectrophotometric determination of ferrous and total iron in monominerals by flow injection combined with a Schlenk line-based digestion apparatus to exclude oxygen

被引:6
|
作者
Xue, Ding-Shuai [1 ,2 ,3 ]
Chen, Guo-Ju [4 ]
Su, Ben-Xun [1 ]
Liu, Yan-Hong [1 ]
Zhang, Dan-Ping [1 ]
Guo, Qian [1 ]
Guo, Ju-Jie [1 ]
Sun, Jie-Fang [5 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, POB 9825, Beijing 100029, Peoples R China
[2] Chinese Acad Sci, Innovat Acad Earth Sci, Beijing 100029, Peoples R China
[3] Univ Chinese Acad Sci, Coll Earth & Planetary Sci, Beijing, Peoples R China
[4] State Key Lab Comprehens Utilizat Nickel & Cobalt, Jinchang 737100, Gansu, Peoples R China
[5] Beijing Ctr Dis Prevent & Control, Beijing Key Lab Diagnost & Traceabil Technol Food, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
On-line photochemical method; Ferrous iron; Total iron; Monomineral; Flow injection; Schlenk line; SILICATE ROCKS; TRACE-ELEMENTS; FERRIC IRON; FE(II); SPECIATION; SOILS; 1,10-PHENANTHROLINE; EXTRACTION; MINERALS;
D O I
10.1016/j.microc.2020.104743
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line photochemical method for measuring the ferrous iron [Fe(II)] and total iron [Fe(T)] contents in monominerals is described herein. A special digestion apparatus connected with a Schlenk line was designed to exclude oxygen during sample digestion. Subsequently, a spectrophotometric flow injection analysis (FIA) system was employed to automate the determination. As a result, a facile, reliable, and accurate analytical procedure was obtained, and both the sample and reagent consumption were reduced compared with traditional spectrophotometric procedures. In addition, the concentrations of the reductant and the chromogenic agent were optimized along with the sample leaching conditions (e.g., the amounts of H2SO4 and HF). Furthermore, the method precision was assessed by comparing the obtained results with those of four geological reference materials (relative standard deviation (RSD) for Fe(II) <2.30%, RSD for Fe(T) <1.75%). Finally, the accuracy of the method was assessed for four monomineral samples using the standard addition method, with recovery percentages of 95.74-104.69% and 95.07-104.56% being obtained for Fe(II) and Fe(T), respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] An Improved Procedure for the Determination of Ferrous Iron Mass Fraction in Silicate Rocks Using a Schlenk Line-Based Digestion Apparatus to Exclude Oxygen
    Xue, Dingshuai
    Wang, Hongyue
    Liu, Yanhong
    Xie, Liewen
    Shen, Ping
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2017, 41 (03) : 411 - 425
  • [2] Online Flow-Based Spectrophotometric Determination of Ferrous Iron Mass Fraction and Total Iron Mass Fraction in Twenty-Seven Rock Reference Materials Using a Schlenk line Technique
    Xue, Ding-Shuai
    Su, Ben-Xun
    Liu, Yan-Hong
    Zhang, Dan-Ping
    Guo, Qian
    Guo, Ju-Jie
    Sun, Jie-Fang
    Sakyi, Patrick Asamoah
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (04) : 785 - 804
  • [3] Spectrophotometric flow injection determination of total phosphorus in beer using on-line UV/thermal induced digestion
    S. M. V. Fernandes
    J. L. F. C. Lima
    A. O. S. S. Rangel
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 112 - 115
  • [4] Determination of iron(II) and total iron using flow injection on-line preconcentration with FAAS
    Xu, GM
    Ye, YX
    Yin, XF
    Shen, H
    Ali, A
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (03): : 350 - 353
  • [5] Total nitrogen determination by flow injection using on-line microwave-assisted digestion
    Cerda, A
    Oms, MT
    Forteza, R
    Cerda, V
    ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 273 - 279
  • [6] On-line determination of iron(II) and iron(III) using a spectrophotometric sequential injection system
    Mulaudzi, LV
    van Staden, JF
    Stefan, RI
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 35 - 49
  • [7] Flow injection spectrophotometric determination of fosfestrol, following on-line thermal induced digestion and using an orthophosphate calibration graph
    Tzanavaras, PD
    Themelis, DG
    TALANTA, 2003, 59 (01) : 207 - 213
  • [8] Determination of total phosphorus in waters and wastewaters by on-line UV/thermal induced digestion and flow injection analysis
    Benson, RL
    McKelvie, ID
    Hart, BT
    Truong, YB
    Hamilton, IC
    ANALYTICA CHIMICA ACTA, 1996, 326 (1-3) : 29 - 39
  • [9] On-line flow injection solid sample introduction digestion and analysis: spectrophotometric and atomic absorption determination of iron, copper and zinc in multi-vitamin tablets
    Sweileh, JA
    MICROCHEMICAL JOURNAL, 2000, 65 (01) : 87 - 95
  • [10] Flow injection spectrophotometric determination of the antibiotic fosfomycin in pharmaceutical products and urine samples after on-line thermal-induced digestion
    Tzanavaras, PD
    Themelis, DG
    ANALYTICAL BIOCHEMISTRY, 2002, 304 (02) : 244 - 248