Background and Purpose-Transcranial Doppler ultrasound (TCD) can detect circulating microembolic signals (MES). We focused our attention on tail signs (TS), a signal associated with MES that appeared as a small reversal signal after MES on the high time resolution spectral display. We examined MES and artifacts in an animal study to determine whether TS were specific changes associated with MES and investigated the characteristics of TS in both animal and clinical studies. Methods-In an animal study, adult pigs with venoarterial extracorporeal membrane oxygenation and minimal anticoagulation therapy were used as a model for cerebral embolism. After performing TCD monitoring with a multigated approach, we did an offline analysis to investigate several parameters concerning MES and TS. We also examined TS in patients in a clinical study. Results-From a total of 362 MES investigated in the animal study, 72.9% were followed by TS. We could not find any TS associated with artifacts. The time delay between TS and MES was negatively correlated with the velocity of MES. MES almost always appeared first in the proximal channel, whereas TS conversely appeared first in the distal channel. In the clinical study, we were also able to observe TS associated with MES. Conclusions-TS may represent emboli passing down a branch vessel or twisted downstream vessel, TS are specific for MES and can be used as another criterion for MES identification.
引用
收藏
页码:863 / 866
页数:4
相关论文
共 9 条
[1]   Carotid endarterectomy and intraoperative emboli detection: Correlation of clinical, transcranial Doppler, and magnetic resonance findings [J].
Ackerstaff, RGA ;
Jansen, C ;
Moll, FL .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (05) :543-550
[2]   Intracranial microembolic signals in 500 patients with potential cardiac or carotid embolic source and in normal controls [J].
Georgiadis, D ;
Lindner, A ;
Manz, M ;
Sonntag, M ;
Zunker, P ;
Zerkowski, HR ;
Borggrefe, M .
STROKE, 1997, 28 (06) :1203-1207
[3]   A novel technique for identification of Doppler microembolic signals based on the coincidence method - In vitro and in vivo evaluation [J].
Georgiadis, D ;
Goeke, J ;
Hill, M ;
Konig, M ;
Nabavi, DG ;
Stogbauer, F ;
Zunker, P ;
Ringelstein, EB .
STROKE, 1996, 27 (04) :683-686
[4]   COMPUTERIZED DETECTION OF CEREBRAL EMBOLI AND DISCRIMINATION FROM ARTIFACT USING DOPPLER ULTRASOUND [J].
MARKUS, H ;
LOH, A ;
BROWN, MM .
STROKE, 1993, 24 (11) :1667-1672
[5]   ASYMPTOMATIC CEREBRAL EMBOLIC SIGNALS IN SYMPTOMATIC AND ASYMPTOMATIC CAROTID-ARTERY DISEASE [J].
MARKUS, HS ;
THOMSON, ND ;
BROWN, MM .
BRAIN, 1995, 118 :1005-1011
[6]   Temporal variability of asymptomatic embolization in carotid artery stenosis and optimal recording protocols [J].
Molloy, J ;
Khan, NH ;
Markus, HS .
STROKE, 1998, 29 (06) :1129-1132
[7]   High-resolution emboli detection and differentiation by characteristic postembolic spectral patterns [J].
Ries, F ;
Tiemann, K ;
Pohl, C ;
Bauer, C ;
Mundo, M ;
Becher, H .
STROKE, 1998, 29 (03) :668-672
[8]   BASIC IDENTIFICATION CRITERIA OF DOPPLER MICROEMBOLIC SIGNALS [J].
SPENCER, MP ;
ACKERSTAFF, RGA ;
BABIKIAN, VL ;
GEORGIADIS, D ;
RUSSELL, D ;
SIEBLER, M ;
STUMP, D .
STROKE, 1995, 26 (06) :1123-1123
[9]   DETECTION OF MIDDLE CEREBRAL-ARTERY EMBOLI DURING CAROTID ENDARTERECTOMY USING TRANSCRANIAL DOPPLER ULTRASONOGRAPHY [J].
SPENCER, MP ;
THOMAS, GI ;
NICHOLLS, SC ;
SAUVAGE, LR .
STROKE, 1990, 21 (03) :415-423