A novel method for estimating SBRT delivered dose with beam's-eye-view images

被引:20
作者
Berbeco, Ross I.
Hacker, Fred
Zatwarnicki, Chris
Park, Sang-June
Ionascu, Dan
O'Farrell, Desmond
Mamon, Harvey J.
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
SBRT; EPID; delivered dose; liver; radiotherapy;
D O I
10.1118/1.2938514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stereotactic body radiation therapy is predicated on a high degree of targeting accuracy. However, inaccurate patient setup as well as intra-fractional motion can hinder the delivery of high doses preferentially to the target. To ensure that the coverage delivered to the patient is as planned, an image-guided verification system has been created to estimate the delivered dose retrospectively. This will not only aid the assessment of treatment techniques, but will also allow for more accurate dose response analysis. Patients with limited hepatic metastases from solid tumors were treated with SBRT. Implanted gold markers were used as target surrogates and a body frame and compression plate provided stereotactic localization and target immobilization, respectively. During treatment, an electronic portal imaging device (EPID), operating in cine mode, collected the exit dose. The sequences of images for each field were processed off-line using in-house software for registration and seed localization. The beam's-eye-view seed positions in the treatment images were compared to those in the DRR's to determine the target shifts in the imaging plane. These target shifts were then imported into the treatment planning software. Each original field was multiplied by the number of images taken during treatment. The calculated shift from each image was then applied to each of the new subfields. Summing all of these subfields together gives the dose distribution that was actually delivered to the patient. The dose-volume histograms for the planned and delivered distributions for four patients' complete treatments are shown. For two of the patients, underdosing due to a setup error or intra-fractional drift was not wholly resolved by subsequent fractions. For one of these patients two alternative corrective strategies have been applied, retrospectively, and the prescribed target coverage recovered for both. The delivered dose can be estimated using the information contained in cine EPID images acquired during irradiation. Calculating the dose actually delivered to the target will allow us to assess treatment procedures as well as more accurately report clinical results. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3225 / 3231
页数:7
相关论文
共 20 条
[1]  
Arslan Sulhattin, 2002, Med Sci Monit, V8, pCR493
[2]  
Berbeco R, 2004, 14 INT C US COMP RAD, P433
[3]   Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers [J].
Berbeco, RI ;
Mostafavi, H ;
Sharp, GC ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4481-4490
[4]   A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode [J].
Berbeco, RI ;
Neicu, T ;
Rietzel, E ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3669-3679
[5]   Clinical feasibility of using an epid in cine mode for image-guided verification of stereotactic body radiotherapy [J].
Berbeco, Ross I. ;
Hacker, Fred ;
Ionascu, Dan ;
Mamon, Harvey J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :258-266
[6]   A real-time MRI guided external beam radiotherapy delivery system [J].
Dempsey, J. ;
Dionne, B. ;
Fitzsimmons, J. ;
Haghigat, A. ;
Li, J. ;
Low, D. ;
Mutic, S. ;
Palta, J. ;
Romeijn, H. ;
Sjoden, G. .
MEDICAL PHYSICS, 2006, 33 (06) :2254-2254
[7]   CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[8]   Marker-less intra-fraction position verification of lung tumors with an EPID in cine mode [J].
Ionascu, D. ;
Park, S. ;
Killoran, J. ;
Allen, A. ;
Berbeco, R. .
MEDICAL PHYSICS, 2007, 34 (06) :2528-2528
[9]   The effect of the Varian amorphous silicon electronic portal imaging device on exit skin dose [J].
Kilby, W ;
Savage, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :3117-3128
[10]   Percutaneous CT-guided biopsy of the lung: Comparison between aspiration and automated cutting needles using a coaxial technique [J].
Laurent, F ;
Latrabe, V ;
Vergier, B ;
Michel, P .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (04) :266-272