Efforts on Improving the Performance of Superimposed-Based Distance Protection

被引:18
作者
Li, Zhengtian [1 ]
Lin, Xiangning [1 ,2 ]
Weng, Hanli [3 ]
Bo, Zhiqian
机构
[1] Huazhong Univ Sci & Technol HUST, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Three Gorges Univ, Coll Elect Engn & Informat Technol, Yichang 443002, Hubei Province, Peoples R China
[3] China Yangtze Power Co Ltd, Three Gorge Hydropower Plant, Yichang 443133, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Adaptive; distance protection; power swing; superimposed; transmission line; FAULT; ALGORITHM; POWER; SCHEME;
D O I
10.1109/TPWRD.2011.2170225
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Existing superimposed-based distance protection possibly maloperates due to some extreme conditions, for instance, an external earth fault occurring while the transmission system operates at a large phase difference between the sources at two sides of the protected line. To solve this problem, an adaptive distance relay using the superimposed component and the information of the opposite end is put forward. The shortages of the existing schemes are first investigated, and the scenarios leading to the maloperations of those schemes in theory are clarified. Furthermore, corresponding countermeasures by means of the floating threshold and criterion switching are introduced. In this case, the reliability and the sensitivity of the superimposed-based distance protection are improved. By means of a variety of comprehensive tests, the feasibility of the proposed scheme is verified.
引用
收藏
页码:186 / 194
页数:9
相关论文
共 18 条
[1]  
Chaudhuri B, 2005, IEEE POWER ENG SOC, P1447
[2]  
Chen W, 2002, POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, P300, DOI 10.1109/ICPST.2002.1053553
[3]   A novel distance protection scheme using time-frequency analysis and pattern recognition approach [J].
Dash, P. K. ;
Samantaray, S. R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2007, 29 (02) :129-137
[4]   Synchronized Phasor Measurement Applications in Power Systems [J].
De La Ree, Jaime ;
Centeno, Virgilio ;
Thorp, James S. ;
Phadke, A. G. .
IEEE TRANSACTIONS ON SMART GRID, 2010, 1 (01) :20-27
[5]   Design and evaluation of a directional algorithm for transmission-line protection based on positive-sequence fault components [J].
Gao, H. ;
Crossley, P. A. .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (06) :711-718
[6]  
Guorong S., 1983, AUTOM ELECT POWER SY, V11, P28
[7]   EPOCHS: A platform for agent-based electric power and communication simulation built from commercial off-the-shelf components [J].
Hopkinson, K ;
Wang, XR ;
Giovanini, R ;
Thorp, J ;
Birman, K ;
Coury, D .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (02) :548-558
[8]   EPOCHS: Integrated commercial off-the-shelf software for agent-based electric power and communication simulation [J].
Hopkinson, KM ;
Birman, KP ;
Giovanini, R ;
Coury, DV ;
Wang, XR ;
Thorp, JS .
PROCEEDINGS OF THE 2003 WINTER SIMULATION CONFERENCE, VOLS 1 AND 2, 2003, :1158-1166
[9]  
Huang S., 2007, P OFC NFOEC, P1
[10]   Charging current compensation for distance protection [J].
Kase, Takahiro ;
Kurosawa, Yasuhiro ;
Amo, Hidenari .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) :124-131