The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT

被引:9
作者
Takamura, Kazuhisa [1 ]
Fujimoto, Shinichiro [1 ]
Kawaguchi, Yuko [1 ]
Kato, Etsuro [1 ]
Aoshima, Chihiro [1 ]
Hiki, Makoto [1 ]
Kumamaru, Kanako K. [2 ]
Daida, Hiroyuki [1 ]
机构
[1] Juntendo Univ, Grad Sch Med, Dept Cardiovasc Med, Tokyo, Japan
[2] Juntendo Univ, Grad Sch Med, Dept Radiol, Tokyo, Japan
基金
日本学术振兴会;
关键词
Coronary artery calcification; Subtraction computed tomography; angiography; Radiation dosing; Diagnostic ability; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; DIAGNOSTIC PERFORMANCE; ARTERY STENOSIS; FEASIBILITY; ACCURACY; PROTOCOL;
D O I
10.1016/j.jjcc.2018.05.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although subtraction coronary computed tomography angiography (S-CCTA) has recently been developed to improve the diagnostic ability in patients with severe calcification, increase in radiation exposure remains a concern. The usefulness of S-CCTA using a low-radiation dose protocol was investigated. Methods: S-CCTA in 320-row area detector CT was performed on 84 consecutive patients with suspected obstructive coronary artery disease with Agatston score >= 100. Reconstruction and radiation dose were changed according to the slow filling time (SF) (137.5 ms < SF <= 262.5 ms. Half reconstruction without reduction of the current, 262.5 ms < SF <= 275 ms: automatic patient motion correction with 50% reduction, SF >= 275 ms: full reconstruction with 70% reduction) at a tube voltage of 100 kV. The percentage of patients with non-diagnostic stenosis of calcified coronary artery lesions was calculated in conventional (C-) CCTA, and S-CCTA was calculated based on 84 patients (446 segments) bases. In 27 patients (137 segments) examined by invasive coronary angiography (ICA), the diagnostic ability was investigated regarding the ICA findings as reference standard. Results: The percentage of non-diagnostic patients and segments on C-CCTA vs. S-CCTA was 40.5% vs. 9.5% and 16.4% vs. 2.9%, respectively. The Agatston score was 589.3 +/- 655.3, and the total effective radiation dose (non-contrast scan and C-CCTA) was 2.7 +/- 1.1 mSv. In the 27 patients, 137 segments area under the curve of S-CCTA (0.939, 95% CI: 0.895-0.983) for the ICA findings as reference standard was significantly higher than that of C-CCTA (0.785, 95% Cl: 0.713-0.858) (p < 0.0001). Conclusion: The diagnostic ability of S-CCTA performed following the low-radiation dose protocol for patients with calcification was superior to that of C-CCTA alone. (C) 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 50 条
  • [31] 320-row coronary computed tomography angiography (CCTA) with automatic exposure control (AEC): effect of 100 kV versus 120 kV on image quality and dose exposure
    Di Cesare, Ernesto
    Gennarelli, Antonio
    Di Sibio, Alessandra
    Felli, Valentina
    Perri, Marco
    Splendiani, Alessandra
    Gravina, Giovanni Luca
    Barile, Antonio
    Masciocchi, Carlo
    RADIOLOGIA MEDICA, 2016, 121 (08): : 618 - 625
  • [32] Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner
    Einstein, Andrew J.
    Elliston, Carl D.
    Arai, Andrew E.
    Chen, Marcus Y.
    Mather, Richard
    Pearson, Gregory D. N.
    DeLaPaz, Robert L.
    Nickoloff, Edward
    Dutta, Ajoy
    Brenner, David J.
    RADIOLOGY, 2010, 254 (03) : 698 - 706
  • [33] Image quality and radiation dose of renal perfusion CT with low-dose contrast agent: a comparison with conventional CT using a 320-row system
    Asayama, Y.
    Nishie, A.
    Ishigami, K.
    Ushijima, Y.
    Kakihara, D.
    Fujita, N.
    Morita, K.
    Ishimatsu, K.
    Takao, S.
    Honda, H.
    CLINICAL RADIOLOGY, 2019, 74 (08) : 650.e13 - 650.e18
  • [34] Prospective ECG-gated 320 row detector computed tomography: implications for CT angiography and perfusion imaging
    Kitagawa, Kakuya
    Lardo, Albert C.
    Lima, Joao A. C.
    George, Richard T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 201 - 208
  • [35] Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation
    Dewey, Marc
    Zimmermann, Elke
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Schlattmann, Peter
    Knebel, Fabian
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2009, 120 (10) : 867 - 875
  • [36] Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
    Jiyeon Lim
    Eun-Ah Park
    Whal Lee
    Hackjoon Shim
    Jin Wook Chung
    The International Journal of Cardiovascular Imaging, 2015, 31 : 23 - 30
  • [37] Radiation dose in 320-detector-row CT coronary angiography: Prospective ECG triggering combined with multi-segment reconstruction
    Yang, Ching-Ching
    Wu, Jay
    Tsai, Chia-Jung
    Chen, Chien-Chuan
    Hung, Chien-Fu
    Wu, Tung-Hsin
    RADIATION MEASUREMENTS, 2011, 46 (12) : 2060 - 2064
  • [38] Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
    Lim, Jiyeon
    Park, Eun-Ah
    Lee, Whal
    Shim, Hackjoon
    Chung, Jin Wook
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 23 - 30
  • [39] Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography
    Wan, Yung-Liang
    Tsay, Pei-Kwei
    Chen, Chun-Chi
    Juan, Yu-Hsiang
    Huang, Yu-Chieh
    Chan, Wen-Hui
    Wen, Ming-Shien
    Hsieh, I-Chang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 : S105 - S115
  • [40] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Dogan, Nurullah
    Dursun, Aydin
    Ozkan, Hakan
    Karatas, Serdar
    Celiloglu, Nuran
    Agca, Fahriye Vatansever
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (10) : 1123 - 1134