Comparison of diode laser - Oral tissue interaction to different wavelengths. In vitro study of porcine periodontal pockets and oral mucosa

被引:18
作者
Gutierrez-Corrales, Aida [1 ]
Rizcala-Orlando, Yudex [1 ]
Montero-Miralles, Paloma [1 ]
Volland, Gerd [1 ]
Luis Gutierrez-Perez, Jose [1 ]
Torres-Lagares, Daniel [1 ]
Angeles Serrera-Figallo, Maria [1 ]
机构
[1] Univ Seville, Dent Sch, C Avicena S-N, Seville 41009, Spain
来源
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL | 2020年 / 25卷 / 02期
关键词
Laser surgery; soft tissue; diode laser; KTP laser; thermal damage; necrosis; IRRADIATION; SURGERY; MODEL; NM;
D O I
10.4317/medoral.23317
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The aim of this in vitro study was to evaluate the effect of diode lasers at different wavelengths and power settings in handmade incisions in periodontal pockets and in oral mucosa of porcine tissue considering thermal damage, necrosis and the affected area of the soft tissue. Material and Methods: Combining the following laser wavelengths, 445nm, 532nm (KTP), 810nm, 980nm, 1064nm and 1470nm, and a power range from 0.5W to 2.0W in a continuous wave mode (CW), we made handmade incisions in porcine periodontal pockets and oral mucosa. After histological processing, we measured the area of lost tissue, the area of thermal damage and the area of necrosis. Then, we performed ANOVA to evaluate the difference between groups and two-way ANOVA to identify the influence of the laser-type variables and the power on the results. Results: We applied an ANOVA test to evaluate the results, where statistical analysis showed clear differences between the 1470nm and 810nm laser groups that refer to thermal damage and necrosis in the periodontal pocket surface. Regarding the oral mucosa surface, the 1064nm laser showed differences in the analysis of lost tissue. According to the applied power, all the variables we studied (lost tissue area, area of thermal damage and necrosis) showed higher values when using a power of 2.0W instead of 0.5W. Conclusions: According to our results, the 810nm diode laser for oral soft-tissue biopsy using power ranges between 0.5W and 2W would be the best choice to avoid thermal damage in peri-incisional margins.
引用
收藏
页码:E224 / E232
页数:9
相关论文
共 29 条
[1]  
Akbulut Nihat, 2013, Eur J Dent, V7, P207, DOI 10.4103/1305-7456.110174
[2]   Diode laser (808 nm) applied to oral soft tissue lesions: a retrospective study to assess histopathological diagnosis and evaluate physical damage [J].
Angiero, Francesca ;
Parma, Luisa ;
Crippa, Rolando ;
Benedicenti, Stefano .
LASERS IN MEDICAL SCIENCE, 2012, 27 (02) :383-388
[3]   Periodontal and peri-implant wound healing following laser therapy [J].
Aoki, Akira ;
Mizutani, Koji ;
Schwarz, Frank ;
Sculean, Anton ;
Yukna, Raymond A. ;
Takasaki, Aristeo A. ;
Romanos, Georgios E. ;
Taniguchi, Yoichi ;
Sasaki, Katia M. ;
Zeredo, Jorge L. ;
Koshy, Geena ;
Coluzzi, Donald J. ;
White, Joel M. ;
Abiko, Yoshimitsu ;
Ishikawa, Isao ;
Izumi, Yuichi .
PERIODONTOLOGY 2000, 2015, 68 (01) :217-269
[4]  
Azma E, 2013, J LASERS MED SCI, V4, P206
[5]   Effectiveness of Laser Application for Periodontal Surgical Therapy: Systematic Review and Meta-Analysis [J].
Behdin, Shabnam ;
Monje, Alberto ;
Lin, Guo-Hao ;
Edwards, Bruce ;
Othman, Abdullah ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2015, 86 (12) :1352-1363
[6]   Quality and Survival of Direct Light-Activated Composite Resin Restorations in Posterior Teeth: A 5-to 20-Year Retrospective Longitudinal Study [J].
Borgia, Ernesto ;
Baron, Rosario ;
Luis Borgia, Jose .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01) :E195-E203
[7]   Assessment of the effect of laser irradiations at different wavelengths (660, 810, 980, and 1064 nm) on autophagy in a rat model of mucositis [J].
Bostanciklioglu, Mehmet ;
Demiryurek, Seniz ;
Cengiz, Beyhan ;
Demir, Tuncer ;
Oztuzcu, Serdar ;
Aras, Mutan Hamdi ;
Ozsevik, Semih ;
Usumez, Aslihan ;
Ergun, Sercan ;
Ozbal, Halime Kubra ;
Bagci, Cahit .
LASERS IN MEDICAL SCIENCE, 2015, 30 (04) :1289-1295
[8]   Efficiency of soft tissue incision with a novel 445-nm semiconductor laser [J].
Braun, Andreas ;
Kettner, Moritz ;
Berthold, Michael ;
Wenzler, Johannes-Simon ;
Heymann, Paul Guenther Baptist ;
Frankenberger, Roland .
LASERS IN MEDICAL SCIENCE, 2018, 33 (01) :27-33
[9]   Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents [J].
Castillo-de-Oyaguee, Raquel ;
Sanchez-Turrion, Andres ;
Lopez-Lozano, Jose-Francisco ;
Albaladejo, Alberto ;
Torres-Lagares, Daniel ;
Montero, Javier ;
Suarez-Garcia, Maria-Jesus .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (04) :E610-E617
[10]  
Coluzzi D J, 2000, Dent Clin North Am, V44, P753