Optimization of dispersive liquid-liquid microextraction of copper (II) by atomic absorption spectrometry as its oxinate chelate:: Application to determination of copper in different water samples

被引:146
作者
Farajzadeh, Mir Ali [1 ]
Bahram, Morteza [2 ]
Mehr, Behzad Ghorbani [2 ]
Jonsson, Jan Ake [3 ]
机构
[1] Tabriz Univ, Fac Chem, Dept Analyt Chem, Tabriz, Iran
[2] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
[3] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
dispersive liquid-liquid microextraction; optimization; one variable at a time; central composite design; atomic absorption spectrometry; copper ion determination;
D O I
10.1016/j.talanta.2007.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study a dispersive liquid-liquid microextraction (DLLME) method based on the dispersion of an extraction solvent into aqueous phase in the presence of a dispersive solvent was investigated for the preconcentration of Cu2+ ions. 8-Hydroxy quinoline was used as a chelating agent prior to extraction. Flame atomic absorption spectrometry using an acetylene-air flame was used for quantitation of the analyte after preconcentration. The effect of various experimental parameters on the extraction was investigated using two optimization methods, one variable at a time and central composite design. The experimental design was performed at five levels of the operating parameters. Nearly the same results for optimization were obtained using both methods: sample size 5 mL; volume of dispersive solvent 1.5 mL; dispersive solvent methanol; extracting solvent chloroform; extracting solvent volume 250 mu L; 8-hydroxy quinoline concentration and salt amount do not affect significantly the extraction. Under the optimum conditions the calibration graph was linear over the range 50-2000 mu g L-1. The relative standard deviation was 5.1% for six repeated determinations at a concentration of 500 mu g L-1. The limit of detection (S/N = 3) was 3 mu g L-1. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:832 / 840
页数:9
相关论文
共 32 条
[1]  
American Public Health Association, 1998, STAND METH EX WAT WA
[2]   Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[3]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[4]  
BULACOV J, 2006, SURF COAT TECH, V201, P255
[5]  
DASILVA LHM, 1998, J CHEM SOC CHEM COMM, V4, P1189
[6]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79
[7]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[8]   High-performance liquid chromatographic-spectrophotometric determination of copper(II) and palladium(II) with 5,10,15,20-tetrakis(4N-pyridyl)porphine following homogeneous liquid-liquid extraction in the water-acetic acid-chloroform ternary solvent system [J].
Igarashi, S ;
Ide, N ;
Takagai, Y .
ANALYTICA CHIMICA ACTA, 2000, 424 (02) :263-269
[9]   Homogeneous liquid-liquid extraction followed by X-ray fluorescence spectrometry of a microdroplet on filter-paper for the simultaneous determination of small amounts of metals [J].
Igarashi, S ;
Takahashi, A ;
Ueki, Y ;
Yamaguchi, H .
ANALYST, 2000, 125 (05) :797-798
[10]  
IGARASHI S, 1997, BUNSEKI, V2, P702