Effectiveness of high-frequency repetitive transcranial magnetic stimulation in patients with depression and Parkinson's disease: a meta-analysis of randomized, controlled clinical trials

被引:7
|
作者
Qin, Bin [1 ]
Chen, Hong [1 ]
Gao, Wen [1 ]
Zhao, Li-Bo [2 ]
Zhao, Ming-Jun [3 ]
Qin, Hui-Xun [1 ]
Yang, Ming-Xiu [1 ]
机构
[1] Guangxi Univ Sci & Technol, Affiliated Liuzhou Peoples Hosp, Liuzhou Peoples Hosp, Dept Neurol, 8 Wenchang Rd, Liuzhou 545000, Peoples R China
[2] Chongqing Med Univ, Yongchuan Hosp, Dept Neurol, Chongqing, Peoples R China
[3] Xinxiang Med Univ, Henan Mental Hosp, Affiliated Hosp 2, Dept Pharm, Xinxiang, Peoples R China
关键词
sham-repetitive transcranial magnetic stimulation; selective serotonin re-uptake inhibitors; depressive symptoms; motor symptoms; DOUBLE-BLIND; MAJOR DEPRESSION; RTMS; MOTOR; FLUOXETINE; DIAGNOSIS; EFFICACY; DISORDER; SCALE; TMS;
D O I
10.2147/NDT.S156695
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Aim: This meta-analysis aimed to assess the effect of high-frequency repetitive transcranial magnetic stimulation (HF-rTMS) for the treatment of depression in patients with Parkinson's disease (PD). Methods: The design was a meta-analysis of randomized controlled trials (RCTs). The participants were patients with PD who suffered from depression. The interventions were HF-rTMS alone or in combination with other treatments compared with sham-rTMS, placebo, and anti-depressant treatments. The primary outcome measure was changes in depressive symptoms, defined as the mean change in the total depression score. The secondary outcome was changes in motor symptoms, defined by Unified Parkinson's Disease Rating Scale part III scores, and the acceptability, defined as the risk of all-cause discontinuation. These were expressed as mean differences (MDs), standardized mean differences (SMDs), or risk ratios (RRs) with 95% confidence intervals (CIs). Results: We identified nine suitable trials, with data from 332 participants. For the patients with depression in PD, HF-rTMS was not better than sham-rTMS (SMD=-0.33, 95% CI -0.83 to 0.17) or selective serotonin re-uptake inhibitors (SSRIs) (SMD = 0.07, 95% CI -0.52 to 0.18) for the treatment of depressive symptoms. However, the motor benefits after treatment with HF-rTMS might be better than sham-rTMS (MD=-2.80, 95% CI -5.45 to -0.15) and SSRIs (MD=-2.70, 95% CI -4.51 to -0.90). Conclusion: This meta-analysis provides some evidence that in patients with PD with depression, HF-rTMS may lead to improvement in motor function but not in depression compared with sham-rTMS or SSRIs.
引用
收藏
页码:273 / 284
页数:12
相关论文
共 50 条
  • [1] Repetitive transcranial magnetic stimulation (rTMS) for the treatment of depression in Parkinson disease: a meta-analysis of randomized controlled clinical trials
    Xie, Cheng-Long
    Chen, Jie
    Wang, Xiao-Dan
    Pan, Jia-Lin
    Zhou, Yi
    Lin, Shi-Yi
    Xue, Xiao-Dong
    Wang, Wen-Wen
    NEUROLOGICAL SCIENCES, 2015, 36 (10) : 1751 - 1761
  • [2] Repetitive transcranial magnetic stimulation (rTMS) for the treatment of depression in Parkinson disease: a meta-analysis of randomized controlled clinical trials
    Cheng-Long Xie
    Jie Chen
    Xiao-Dan Wang
    Jia-Lin Pan
    Yi Zhou
    Shi-Yi Lin
    Xiao-Dong Xue
    Wen-Wen Wang
    Neurological Sciences, 2015, 36 : 1751 - 1761
  • [3] Antidepressant Effects of Repetitive Transcranial Magnetic Stimulation Over Prefrontal Cortex of Parkinson's Disease Patients With Depression: A Meta-Analysis
    Zhou, Liang
    Guo, Zhiwei
    Xing, Guoqiang
    Peng, Haitao
    Cai, Mengjie
    Chen, Huaping
    McClure, Morgan A.
    He, Lin
    Xiong, Liangwen
    He, Bin
    Du, Fei
    Mu, Qiwen
    FRONTIERS IN PSYCHIATRY, 2019, 9
  • [4] Repetitive transcranial magnetic stimulation improves cognition, depression, and walking ability in patients with Parkinson's disease: a meta-analysis
    Wang, Mingchen
    Zhang, Wenyu
    Zang, Wanli
    BMC NEUROLOGY, 2024, 24 (01)
  • [5] Repetitive transcranial magnetic stimulation (rTMS) fails to improve cognition in patients with parkinson's disease: a Meta-analysis of randomized controlled trials
    He, Pei Kun
    Wang, Li Min
    Chen, Jia Ning
    Zhang, Yu Hu
    Gao, Yu Yuan
    Xu, Qi Huan
    Qiu, Yi Hui
    Cai, Hui Min
    Li, You
    Huang, Zhi Heng
    Feng, Shu Jun
    Zhao, Jie Hao
    Ma, Gui Xian
    Nie, Kun
    Wang, Li Juan
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2022, 132 (03) : 269 - 282
  • [6] The Effectiveness of High-Frequency Repetitive Transcranial Magnetic Stimulation on Patients with Neuropathic Orofacial Pain: A Systematic Review of Randomized Controlled Trials
    Diao, Yingxiu
    Xie, Yuhua
    Pan, Jiaxin
    Liao, Manxia
    Liu, Hao
    Liao, Linrong
    NEURAL PLASTICITY, 2022, 2022
  • [7] Bilateral vs. unilateral repetitive transcranial magnetic stimulation in treating major depression: A meta-analysis of randomized controlled trials
    Chen, Jian-jun
    Liu, Zhao
    Zhu, Dan
    Li, Qi
    Zhang, Hongzhi
    Huang, Hua
    Wei, Youdong
    Mu, Jun
    Yang, Deyu
    Xie, Peng
    PSYCHIATRY RESEARCH, 2014, 219 (01) : 51 - 57
  • [8] Bilateral repetitive transcranial magnetic stimulation for treatment-resistant depression: a systematic review and meta-analysis of randomized controlled trials
    Zhang, Y. Q.
    Zhu, D.
    Zhou, X. Y.
    Liu, Y. Y.
    Qin, B.
    Ren, G. P.
    Xie, P.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2015, 48 (03) : 198 - 206
  • [9] Efficacy and safety of repetitive transcranial magnetic stimulation for peripartum depression: A meta-analysis of randomized controlled trials
    Liu, Chaomeng
    Pan, Weigang
    Jia, Lina
    Li, Li
    Zhang, Xinyu
    Ren, Yanping
    Ma, Xin
    PSYCHIATRY RESEARCH, 2020, 294
  • [10] Optimal parameter determination of repetitive transcranial magnetic stimulation for treating treatment-resistant depression: A network meta-analysis of randomized controlled trials
    Li, Jinbiao
    Cui, Liqian
    Li, Hao
    FRONTIERS IN PSYCHIATRY, 2022, 13