Evaluation of urinary ribonucleoside profiling for clinical biomarker discovery using constant neutral loss scanning liquid chromatography/tandem mass spectrometry

被引:15
|
作者
Teichert, Friederike [1 ]
Winkler, Swantje [1 ]
Keun, Hector C. [2 ]
Steward, William P. [1 ]
Gescher, Andreas J. [1 ]
Farmer, Peter B. [1 ]
Singh, Rajinder [1 ]
机构
[1] Univ Leicester, Canc Biomarkers & Prevent Grp, Bioctr, Dept Canc Studies & Mol Med, Leicester LE1 7RH, Leics, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, Fac Med, London SW7 2AZ, England
关键词
POTENTIAL TUMOR-MARKERS; MODIFIED NUCLEOSIDES; BREAST-CANCER; CAPILLARY-ELECTROPHORESIS; RNA TURNOVER; BIOLOGICAL MARKERS; COLORECTAL-CANCER; DEGRADATION RATES; EXCRETION; DIAGNOSIS;
D O I
10.1002/rcm.5086
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The patterns and levels of urinary excreted ribonucleosides which reflect RNA turnover and metabolism in humans offer the potential for early detection of disease and monitoring of therapeutic intervention. A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method employing constant neutral loss (CNL) scanning for the loss of the ribose moiety (132 u) was used to detect ribonucleosides in human urine and to evaluate this analytical platform for biomarker research in clinical trials. Ribonucleosides were stable and not influenced by the time spent at room temperature prior to freezing or long-term storage at -80 degrees C. Matrix effects caused variation in the mass spectrometer response which was dependent on the concentration of the analysed urine sample. For the use of urinary ribonucleoside profiling in clinical biomarker studies, adjustment of the urine samples to a common concentration prior to sample preparation is therefore advocated. Changes in the mass spectrometer response should be accounted for by the use of an internal standard added after sample preparation. Diurnal variation exceeded inter-day variation of an individual's ribonucleoside profile, but inter-person differences were predominant and allowed the separation of individuals against each other in a multivariate space. Due to considerable diurnal variation the use of spot urine samples would introduce unnecessary variation and should be replaced by the collection of multiple spot urine samples across the day, where possible. Should such a protocol not be feasible, biological intra-day and inter-day variation must be considered and accounted for in the data interpretation. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:2071 / 2082
页数:12
相关论文
共 50 条
  • [21] Analysis of urinary aromatic acids by liquid chromatography tandem mass spectrometry
    Crow, Brian
    Bishop, Michael
    Paliakov, Ekaterina
    Norton, Dean
    George, Joe
    Bralley, J. Alexander
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (12) : 1346 - 1353
  • [22] Inflammatory disease protein biomarker discovery with multi-dimensional liquid chromatography tandem mass spectrometry.
    Shen, ZX
    Chen, W
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U147 - U147
  • [23] Liquid chromatography-tandem mass spectrometry for clinical diagnostics
    不详
    NATURE REVIEWS METHODS PRIMERS, 2022, 2 (01):
  • [24] RAPID IDENTIFICATION OF CIMETROPIUM BROMIDE METABOLITES USING CONSTANT NEUTRAL LOSS TANDEM MASS-SPECTROMETRY
    NAYLOR, S
    KAJBAF, M
    LAMB, JH
    JAHANSHAHI, M
    GORROD, JW
    BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (03) : 165 - 175
  • [25] Analysis of carbohydrate heterogeneity in a glycoprotein using liquid chromatography mass spectrometry and liquid chromatography with tandem mass spectrometry
    Kawasaki, N
    Ohta, M
    Hyuga, S
    Hashimoto, O
    Hayakawa, T
    ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) : 297 - 303
  • [26] Urine proteomics for profiling of mouse toxoplasmosis using liquid chromatography tandem mass spectrometry analysis
    Lin-Lin Cui
    Chun-Xue Zhou
    Bing Han
    Sha-Sha Wang
    Si-Ying Li
    Shi-Chen Xie
    Dong-Hui Zhou
    Parasites & Vectors, 14
  • [27] Pattern profiling of the herbal preparation picroliv using liquid chromatography-tandem mass spectrometry
    Kumar, V
    Mehrotra, N
    Lal, J
    Gupta, RC
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) : 145 - 152
  • [28] Urine proteomics for profiling of mouse toxoplasmosis using liquid chromatography tandem mass spectrometry analysis
    Cui, Lin-Lin
    Zhou, Chun-Xue
    Han, Bing
    Wang, Sha-Sha
    Li, Si-Ying
    Xie, Shi-Chen
    Zhou, Dong-Hui
    PARASITES & VECTORS, 2021, 14 (01)
  • [29] Discovery of dopamine glucuronide in brain microdialysis samples using liquid chromatography tandem mass spectrometry
    Uutela, P.
    Karhu, L.
    Ketola, R.
    Kostiainen, R.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 34 (01) : S33 - S34
  • [30] A high-throughput liquid chromatography/tandem mass spectrometry method for screening glutathione conjugates using exact mass neutral loss acquisition
    Castro-Perez, J
    Plumb, R
    Liang, L
    Yang, E
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (06) : 798 - 804