Experimental investigation on the mean drop size and drop size distribution in an L-shaped pulsed sieve-plate column

被引:16
|
作者
Amani, Pouria [1 ]
Safdari, Jaber [2 ]
Esmaieli, Mohamad [1 ]
Mallah, Mohammad Hassan [2 ]
机构
[1] Univ Tehran, Coll Engn, Sch Chem Engn, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Mat & Nucl Fuel Res Sch, POB 11365-8486, Tehran, Iran
关键词
L-shaped pulsed plate column; Sauter mean diameter; log-normal probability density function; interfacial tension; drop size distribution; LIQUID-LIQUID-EXTRACTION; ROTATING-DISC CONTACTOR; DISPERSED PHASE HOLDUP; MASS-TRANSFER; SOLVENT-EXTRACTION; HYDRODYNAMIC BEHAVIOR; CHARACTERISTIC VELOCITY; PREDICTION; SEPARATION;
D O I
10.1080/01496395.2017.1374974
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Vertical pulsed extraction columns cannot be employed in applications with height limitations. On the other hand, the horizontal extraction columns have low throughput, which affects their applicability in industrial applications. Therefore, there is a need to design a new type of extractors for such circumstances. In this paper, an experimental study on drop sizes has been implemented in a novel L-shaped pulsed sieve-plate extraction column in the absence and presence of mass transfer. Moreover, new correlations are developed for prediction of the mean drop size and size distribution using the log-normal probability density function.
引用
收藏
页码:2742 / 2755
页数:14
相关论文
共 50 条
  • [41] A correlation for drop size and slip velocity in reciprocating plate column
    S. Joseph
    Y. B. G. Varma
    Bioprocess Engineering, 1998, 18 : 367 - 371
  • [42] Drop breakage in a coalescence-dispersion pulsed-sieve-plate extraction column
    Luo, G.S.
    Li, H.B.
    Tang, X.J.
    Wang, J.D.
    Chemical Engineering Journal, 2004, 102 (02): : 185 - 191
  • [43] Drop breakage in a coalescence-dispersion pulsed-sieve-plate extraction column
    Luo, GS
    Li, HB
    Tang, XJ
    Wang, JD
    CHEMICAL ENGINEERING JOURNAL, 2004, 102 (02) : 185 - 191
  • [44] Investigation of flow dynamics of single phase in a pulsed sieve-plate column using radiotracer technique
    Goswami, Sunil
    Sen, Nirvik
    Samantray, J. S.
    Dash, A.
    Sharma, V. K.
    Sheony, K. T.
    Pant, H. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 313 (03) : 669 - 676
  • [45] Investigation of flow dynamics of single phase in a pulsed sieve-plate column using radiotracer technique
    Sunil Goswami
    Nirvik Sen
    J. S. Samantray
    A. Dash
    V. K. Sharma
    K. T. Sheony
    H. J. Pant
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 313 : 669 - 676
  • [46] An Improved Correlation of the Mean Drop Size in a Modified Scheibel Extraction Column
    Yuan, Shenfeng
    Jin, Shuangfeng
    Chen, Zhirong
    Yuan, Yanna
    Yin, Hong
    CHEMICAL ENGINEERING & TECHNOLOGY, 2014, 37 (12) : 2165 - 2174
  • [47] DROP SIZE DISTRIBUTION AND HOLDUP IN A ROTATING IMPELLER EXTRACTION COLUMN
    LEE, YK
    JU, DP
    KIM, C
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 8 (02) : 80 - 87
  • [48] DROP SIZE DISTRIBUTION AND HOLDUP PROFILES IN A MULTISTAGE EXTRACTION COLUMN
    TSOURIS, C
    KIROU, VI
    TAVLARIDES, LL
    AICHE JOURNAL, 1994, 40 (03) : 407 - 418
  • [49] DROP BREAKUP IN TURBULENT STIRRED-TANK CONTACTORS .3. CORRELATIONS FOR MEAN SIZE AND DROP SIZE DISTRIBUTION
    CALABRESE, RV
    WANG, CY
    BRYNER, NP
    AICHE JOURNAL, 1986, 32 (04) : 677 - 681
  • [50] PREDICTION OF DROP SIZE IN PULSED PERFORATED-PLATE EXTRACTION COLUMNS
    KUMAR, A
    HARTLAND, S
    CHEMICAL ENGINEERING COMMUNICATIONS, 1986, 44 (1-6) : 163 - 182