Experimental investigation on the mean drop size and drop size distribution in an L-shaped pulsed sieve-plate column

被引:16
|
作者
Amani, Pouria [1 ]
Safdari, Jaber [2 ]
Esmaieli, Mohamad [1 ]
Mallah, Mohammad Hassan [2 ]
机构
[1] Univ Tehran, Coll Engn, Sch Chem Engn, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Mat & Nucl Fuel Res Sch, POB 11365-8486, Tehran, Iran
关键词
L-shaped pulsed plate column; Sauter mean diameter; log-normal probability density function; interfacial tension; drop size distribution; LIQUID-LIQUID-EXTRACTION; ROTATING-DISC CONTACTOR; DISPERSED PHASE HOLDUP; MASS-TRANSFER; SOLVENT-EXTRACTION; HYDRODYNAMIC BEHAVIOR; CHARACTERISTIC VELOCITY; PREDICTION; SEPARATION;
D O I
10.1080/01496395.2017.1374974
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Vertical pulsed extraction columns cannot be employed in applications with height limitations. On the other hand, the horizontal extraction columns have low throughput, which affects their applicability in industrial applications. Therefore, there is a need to design a new type of extractors for such circumstances. In this paper, an experimental study on drop sizes has been implemented in a novel L-shaped pulsed sieve-plate extraction column in the absence and presence of mass transfer. Moreover, new correlations are developed for prediction of the mean drop size and size distribution using the log-normal probability density function.
引用
收藏
页码:2742 / 2755
页数:14
相关论文
共 50 条
  • [31] Experimental investigation on regime transition and characteristic velocity in a horizontal-vertical pulsed sieve-plate column
    Akhgar, Sahar
    Safdari, Jaber
    Towfighi, Jafar
    Amani, Pouria
    Mallah, Mohammad H.
    RSC ADVANCES, 2017, 7 (04): : 2288 - 2300
  • [32] DROP SIZE AND HOLDUP IN A RECIPROCATING PLATE EXTRACTION COLUMN
    BAIRD, MHI
    LANE, SJ
    CHEMICAL ENGINEERING SCIENCE, 1973, 28 (03) : 947 - 957
  • [33] Study of mass transfer and determination of drop size distribution in a pulsed extraction column
    Ousmane, Syll
    Isabelle, Mabille
    Mario, Moscosa-Santillan
    Mamadou, Traore
    Jacques, Amouroux
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (1A): : 60 - 68
  • [34] A study of drop size distribution and mean drop size in a perforated rotating disc contactor (PRDC)
    Hemmati, Alireza
    Torab-Mostaedi, Meisam
    Shirvani, Mansour
    Ghaemi, Ahad
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2015, 96 : 54 - 62
  • [35] A study on mean drop size and drop size distribution in an eductor liquid-liquid extractor
    Hosseinzadeh, Mostafa
    Shirvani, Mansour
    Ghaemi, Ahad
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 201 : 205 - 213
  • [36] ON THE FLOODING POINT IN PULSED SIEVE-PLATE EXTRACTION COLUMNS, PAYING ATTENTION TO EXPERIMENTAL DROPLET SIZE DATA
    AUFDERHEIDE, E
    VOGELPOHL, A
    CHEMIE INGENIEUR TECHNIK, 1984, 56 (09) : 724 - 725
  • [37] Flooding and drop size in a pulsed disc and doughnut extraction column
    Torab-Mostaedi, Meisam
    Ghaemi, Ahad
    Asadollahzadeh, Mehdi
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (12A): : 2742 - 2751
  • [39] A correlation for drop size and slip velocity in reciprocating plate column
    Joseph, S
    Varma, YBG
    BIOPROCESS ENGINEERING, 1998, 18 (05) : 367 - 371
  • [40] The Use of an Ionic Liquid in a Karr Reciprocating Plate Extraction Column: Drop Size Distribution
    Yung, Kelly K. L.
    Smith, Craig D.
    Bowser, Tim
    Perera, Jilska M.
    Stevens, Geoffrey W.
    SEPARATION SCIENCE AND TECHNOLOGY, 2012, 47 (12) : 1733 - 1739