Experimental investigation on the mean drop size and drop size distribution in an L-shaped pulsed sieve-plate column

被引:16
|
作者
Amani, Pouria [1 ]
Safdari, Jaber [2 ]
Esmaieli, Mohamad [1 ]
Mallah, Mohammad Hassan [2 ]
机构
[1] Univ Tehran, Coll Engn, Sch Chem Engn, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Mat & Nucl Fuel Res Sch, POB 11365-8486, Tehran, Iran
关键词
L-shaped pulsed plate column; Sauter mean diameter; log-normal probability density function; interfacial tension; drop size distribution; LIQUID-LIQUID-EXTRACTION; ROTATING-DISC CONTACTOR; DISPERSED PHASE HOLDUP; MASS-TRANSFER; SOLVENT-EXTRACTION; HYDRODYNAMIC BEHAVIOR; CHARACTERISTIC VELOCITY; PREDICTION; SEPARATION;
D O I
10.1080/01496395.2017.1374974
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Vertical pulsed extraction columns cannot be employed in applications with height limitations. On the other hand, the horizontal extraction columns have low throughput, which affects their applicability in industrial applications. Therefore, there is a need to design a new type of extractors for such circumstances. In this paper, an experimental study on drop sizes has been implemented in a novel L-shaped pulsed sieve-plate extraction column in the absence and presence of mass transfer. Moreover, new correlations are developed for prediction of the mean drop size and size distribution using the log-normal probability density function.
引用
收藏
页码:2742 / 2755
页数:14
相关论文
共 50 条
  • [21] Drop-size distribution and average drop size in a Wirz extraction column
    Rincon-Rubio, L.M.
    Kumar, A.
    Hartland, S.
    Chemical Engineering Research and Design, 1994, 72 (A4) : 493 - 502
  • [22] DROP-SIZE DISTRIBUTION AND AVERAGE DROP SIZE IN A WIRZ EXTRACTION COLUMN
    RINCONRUBIO, LM
    KUMAR, A
    HARTLAND, S
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1994, 72 (A4): : 493 - 502
  • [23] Experimental Investigation of Flooding and Drop Size in a Kuhni Extraction Column
    Shirvani, A. R.
    Ghaemi, A.
    Torab-Mostaedi, M.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2016, 29 (03): : 288 - 296
  • [24] DISPERSED PHASE HOLDUP AND DROP SIZE DISTRIBUTION IN PULSED PLATE COLUMNS
    PRABHAKAR, A
    SRINIKETAN, G
    VARMA, YBG
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1988, 66 (02): : 232 - 240
  • [25] Drop size and drop size distribution in a liquid-liquid extraction spray column
    Saeed, M. T.
    Jamil, M.
    Perez De Ortiz, E. S.
    Pakistan Journal of Scientific and Industrial Research, 1994, 37 (08):
  • [26] Comparison of dispersed phase holdup and slip velocity in chemical systems with different interfacial tension in an L-shaped pulsed sieve-plate extraction column
    Ardestani, Fatemeh
    Ghaemi, Ahad
    Hemmati, Alireza
    Safdari, Jaber
    Rafiei, Vahid
    PROGRESS IN NUCLEAR ENERGY, 2023, 159
  • [27] The influence of impeller type on mean drop size and drop size distribution in an agitated vessel
    Pacek, AW
    Chamsart, S
    Nienow, AW
    Bakker, A
    CHEMICAL ENGINEERING SCIENCE, 1999, 54 (19) : 4211 - 4222
  • [28] Hydrodynamic performance of a pulsed extraction column containing ZnO nanoparticles: Drop size and size distribution
    Amani, Pouria
    Amani, Mohammad
    Saidur, R.
    Yan, Wei-Mon
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 121 : 275 - 286
  • [29] Investigation of mass transfer performance in an L-shaped pulsed sieve plate extraction column using axial dispersion model
    Rafiei, Vahid
    Safdari, Jaber
    Moradi, Sadegh
    Amani, Pouria
    Mallah, Mohammad H.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 128 : 130 - 145
  • [30] HOLDUP AND AXIAL DISTRIBUTION OF HOLDUP IN A PULSED SIEVE-PLATE SOLVENT EXTRACTION COLUMN
    BELL, RL