Experimental investigation on the mean drop size and drop size distribution in an L-shaped pulsed sieve-plate column

被引:17
作者
Amani, Pouria [1 ]
Safdari, Jaber [2 ]
Esmaieli, Mohamad [1 ]
Mallah, Mohammad Hassan [2 ]
机构
[1] Univ Tehran, Coll Engn, Sch Chem Engn, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Mat & Nucl Fuel Res Sch, POB 11365-8486, Tehran, Iran
关键词
L-shaped pulsed plate column; Sauter mean diameter; log-normal probability density function; interfacial tension; drop size distribution; LIQUID-LIQUID-EXTRACTION; ROTATING-DISC CONTACTOR; DISPERSED PHASE HOLDUP; MASS-TRANSFER; SOLVENT-EXTRACTION; HYDRODYNAMIC BEHAVIOR; CHARACTERISTIC VELOCITY; PREDICTION; SEPARATION;
D O I
10.1080/01496395.2017.1374974
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Vertical pulsed extraction columns cannot be employed in applications with height limitations. On the other hand, the horizontal extraction columns have low throughput, which affects their applicability in industrial applications. Therefore, there is a need to design a new type of extractors for such circumstances. In this paper, an experimental study on drop sizes has been implemented in a novel L-shaped pulsed sieve-plate extraction column in the absence and presence of mass transfer. Moreover, new correlations are developed for prediction of the mean drop size and size distribution using the log-normal probability density function.
引用
收藏
页码:2742 / 2755
页数:14
相关论文
共 45 条
[1]   Mean Drop Size Correlations and Population Balance Models for Liquid-Liquid Dispersion [J].
Abidin, Mohd Izzudin Izzat Zainal ;
Raman, Abdul Aziz Abdul ;
Nor, Mohamad Iskandr Mohamad .
AICHE JOURNAL, 2015, 61 (04) :1129-1145
[2]   Experimental investigation on regime transition and characteristic velocity in a horizontal-vertical pulsed sieve-plate column [J].
Akhgar, Sahar ;
Safdari, Jaber ;
Towfighi, Jafar ;
Amani, Pouria ;
Mallah, Mohammad H. .
RSC ADVANCES, 2017, 7 (04) :2288-2300
[3]  
Amani P., 2017, CHEM ENG RES DES, V167, P135
[4]   Mass transfer studies in a horizontal pulsed sieve-plate column for uranium extraction by tri-n-octylamine using axial dispersion model [J].
Amani, Pouria ;
Safdari, Jaber ;
Gharib, Ahmad ;
Badakhshan, Hossein ;
Mallah, Mohammad H. .
PROGRESS IN NUCLEAR ENERGY, 2017, 98 :71-84
[5]   Investigation of hydrodynamic and mass transfer of mercaptan extraction in pulsed and non-pulsed packed columns [J].
Amani, Pouria ;
Amani, Mohammad ;
Hasanvandian, Reza .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2017, 34 (05) :1456-1465
[6]   Two-phase pressure drop and flooding characteristics in a horizontal-vertical pulsed sieve-plate column [J].
Amani, Pouria ;
Safdari, Jaber ;
Abolghasemi, Hossein ;
Mallah, Mohammad H. ;
Davari, Amin .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2017, 65 :266-276
[7]  
ANGELINO H, 1967, BRIT CHEM ENG PR TEC, V12, P1893
[8]   ON THE SIZE OF DROPS IN PULSED AND VIBRATING PLATE EXTRACTION COLUMNS [J].
BOYADZHIEV, L ;
SPASSOV, M .
CHEMICAL ENGINEERING SCIENCE, 1982, 37 (02) :337-340
[9]   Mass transfer and ZETA potential in solvent extraction [J].
Czapla, C ;
Bart, HJ ;
Jesberger, M .
SEPARATION SCIENCE AND TECHNOLOGY, 2000, 35 (09) :1423-1438
[10]   Steady state modeling of perforated plate extraction columns [J].
Ettouney, R. S. ;
El-Rifai, M. A. ;
Ghallab, A. O. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2007, 46 (08) :713-720