Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D

被引:19
|
作者
Tatsugami, Fuminari [1 ]
Higaki, Toru [1 ]
Fukumoto, Wataru [1 ]
Kaichi, Yoko [1 ]
Fujioka, Chikako [2 ]
Kiguchi, Masao [2 ]
Yamamoto, Hideya [3 ]
Kihara, Yasuki [3 ]
Awai, Kazuo [1 ]
机构
[1] Hiroshima Univ, Dept Diagnost Radiol, Minami Ku, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Dept Radiol, Minami Ku, Hiroshima 7348551, Japan
[3] Hiroshima Univ, Dept Cardiovasc Med, Minami Ku, Hiroshima 7348551, Japan
关键词
Coronary artery calcium; Iterative reconstruction; Dose reduction; 320-detector CT scanner; MULTIDETECTOR ROW CT; ULTRAFAST COMPUTED-TOMOGRAPHY; TRIGGERED 64-SLICE CT; INTERSCAN VARIABILITY; HEART-ASSOCIATION; CARDIAC CT; QUANTIFICATION; ANGIOGRAPHY; RECONSTRUCTION; REPRODUCIBILITY;
D O I
10.1007/s10554-015-0637-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the possibility of reducing the radiation dose for coronary artery calcium (CAC) scoring by using adaptive iterative dose reduction 3D (AIDR 3D) on a 320-detector CT scanner. Fifty-four patients underwent routine- and low-dose CT for CAC scoring. Low-dose CT was performed at one-third of the tube current used for routine-dose CT. Routine-dose CT was reconstructed with filtered back projection (FBP) and low-dose CT was reconstructed with AIDR 3D. We compared the calculated Agatston-, volume-, and mass scores of these images. The overall percentage difference in the Agatston-, volume-, and mass scores between routine- and low-dose CT studies was 15.9, 11.6, and 12.6 %, respectively. There were no significant differences in the routine- and low-dose CT studies irrespective of the scoring algorithms applied. The CAC measurements of both imaging modalities were highly correlated with respect to the Agatston- (r = 0.996), volume- (r = 0.996), and mass score (r = 0.997; p < 0.001, all); the Bland-Altman limits of agreement scores were -37.4 to 51.4, -31.2 to 36.4 and -30.3 to 40.9 %, respectively, suggesting that AIDR 3D was a good alternative for FBP. The mean effective radiation dose for routine- and low-dose CT was 2.2 and 0.7 mSv, respectively. The use of AIDR 3D made it possible to reduce the radiation dose by 67 % for CAC scoring without impairing the quantification of coronary calcification.
引用
收藏
页码:1045 / 1052
页数:8
相关论文
共 50 条
  • [41] The impact of adaptive iterative dose reduction 3D on the improvement of shoulder image quality in head and neck CTA
    Zhang, Li
    Chen, Yue-feng
    Che, Yan-xu
    Xu, Yan-feng
    Zheng, Jing
    Yu, Shu-jing
    CURRENT MEDICAL RESEARCH AND OPINION, 2019, 35 (05) : 887 - 891
  • [42] CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction
    Ullrich Ebersberger
    Francesco Tricarico
    U. Joseph Schoepf
    Philipp Blanke
    J. Reid Spears
    Garrett W. Rowe
    William T. Halligan
    Thomas Henzler
    Fabian Bamberg
    Alexander W. Leber
    Ellen Hoffmann
    Paul Apfaltrer
    European Radiology, 2013, 23 : 125 - 132
  • [43] Forward-Projected Model-Based Iterative Reconstruction in Screening Low-Dose Chest CT: Comparison With Adaptive Iterative Dose Reduction 3D
    Hassani, Cameron
    Ronco, Anthony
    Prosper, Ashley E.
    Dissanayake, Sumudu
    Cen, Steven Y.
    Lee, Christopher
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 548 - 556
  • [44] Dose reduction techniques in coronary calcium scoring: The effect of iterative reconstruction combined with low tube voltage on calcium scores in a thoracic phantom
    Vonder, Marleen
    Pelgrim, Gert Jan
    Meyer, Mathias
    Henzler, Thomas
    Oudkerk, Matthijs
    Vliegenthart, Rozemarijn
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 229 - 235
  • [45] Pilot Study on Image Quality and Radiation Dose of CT Colonography with Adaptive Iterative Dose Reduction Three-Dimensional
    Shen, Hesong
    Liang, Dan
    Luo, Mingyue
    Duan, Chaijie
    Cai, Wenli
    Zhu, Shanshan
    Qiu, Jianping
    Li, Wenru
    PLOS ONE, 2015, 10 (01):
  • [46] Dose reduction for CT coronary calcium scoring with a calcium-aware image reconstruction technique: a phantom study
    Booij, Ronald
    van der Werf, Niels R.
    Budde, Ricardo P. J.
    Bos, Daniel
    van Straten, Marcel
    EUROPEAN RADIOLOGY, 2020, 30 (06) : 3346 - 3355
  • [47] Submillisievert Median Radiation Dose for Coronary Angiography with a Second-Generation 320-Detector Row CT Scanner in 107 Consecutive Patients
    Chen, Marcus Y.
    Shanbhag, Sujata M.
    Arai, Andrew E.
    RADIOLOGY, 2013, 267 (01) : 76 - 85
  • [48] Image quality and radiation exposure in CT of the pancreas: 320-MDCT with and without adaptive iterative dose reduction versus 64-MDCT
    Goshima, S.
    Kanematsu, M.
    Nishibori, H.
    Miyazawa, D.
    Kondo, H.
    Moriyama, N.
    Bae, K. T.
    CLINICAL RADIOLOGY, 2013, 68 (11) : E593 - E600
  • [49] Accuracy of coronary artery calcium scoring with tube current reduction by 75%, using an adaptive iterative reconstruction algorithm
    Luhur, Reny
    Schuijf, Joanne D.
    Mews, Jurgen
    Blobel, Jorg
    Ham, Bernd
    Lembcke, Alexander
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084)
  • [50] Assessment of iterative image reconstruction on kidney and liver donors: Potential role of adaptive iterative dose reduction 3D (AIDR 3D) technology
    Maamoun, I
    Khalil, Magdy M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 109 : 124 - 129