Implant Impression Techniques using Different Materials and Methods: A Review

被引:2
|
作者
Yasar, Muhammed Necati [1 ]
Cetinsahin, Cem [1 ]
Bayar, Omer [1 ]
Ozer, Hasan Yildrim [1 ]
机构
[1] Baskent Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Conventional impression; Custom tray; Digital dentistry; Intraoral digital impression; Slicone elastomers; EDENTULOUS PATIENTS; IN-VITRO; ACCURACY; ANGULATION; PROSTHESES; TIME; FIT;
D O I
10.7860/JCDR/2022/53057.16014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dental implants have emerged as the treatment of choice in for restoring missing teeth in situations that require functional and aesthetic replacements. Reproduction of the position and orientation of intraoral implants by means of an accurate impression in the definitive cast is the first step in achieving a passively fitting multi-implant supported prosthesis, to decrease the mechanical and biological complication of the prosthesis. The accuracy of the impression making procedure in the usage of osseointegrated implants used for the rehabilitation of fully and partially edentulous patients is a very important factor for the long-term success of dental implants. It has been reported that the precision of implant impressions is affected by various factors such as impression materials, impression technique, splinting of impression posts, impression level and depth, as well as the angle of the implants. Also, the incompatibility between implant and prosthesis, which may occur as a result of an incorrect impression, may cause problems such as screw loosening, screw fracture, loss of osseointegration and even implant fracture. Today, there are many articles and reviews about implant impressions. Although the authors found consistent results in many studies, there are differences of opinion on some issues. In general, polyether and additional type silicones were found to be successful in the conventional impression technique. Digital impression technique, on the other hand, has been found as successful as conventional measurement techniques in some studies. Controversial results have been obtained about the number of implants and their angulation. In general, the direct open tray splinted impression method is recommended for four or more implants, while there was no difference between the direct or indirect method for three or less implants.
引用
收藏
页码:ZE12 / ZE17
页数:6
相关论文
共 50 条
  • [41] Accuracy of implant impression techniques with a scannable healing abutment
    Jung, Hong-Taek
    Kim, Ha-Young
    Song, So-Yeon
    Park, Jin-Hong
    Lee, Jeong-Yol
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 729 - 734
  • [42] Accuracy of Impression Techniques for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 715 - 721
  • [43] AN IN VITRO COMPARISON OF PHOTOGRAMMETRIC AND CONVENTIONAL COMPLETE-ARCH IMPLANT IMPRESSION TECHNIQUES
    Bergin, Junping Ma
    Rubenstein, Jeffrey E.
    Mancl, Lloyd
    Brudvik, James S.
    Raigrodski, Ariel J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (04) : 243 - 251
  • [44] Accuracy of data obtained from impression scans and cast scans using different impression materials
    Keul, Christine
    Runkel, Cornelius
    Guth, Jan-Frederik
    Schubert, Oliver
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2020, 23 (02) : 129 - 138
  • [45] Evaluation of the Three-Dimensional Accuracy of Implant Impression Techniques in Two Simulated Clinical Conditions by Optical Scanning
    Sabouhi, Mahmoud
    Bajoghli, Farshad
    Abolhasani, Majid
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 26 - 34
  • [46] Three-dimensional accuracy of innovative implant-level impression techniques with plastic snap-on impression copings
    Asli, Hamid Neshandar
    Hemmati, Yasamin Babaee
    Falahchai, Mehran
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (03) : 351 - 357
  • [47] Effect of the Association Between the Tray and Impression Techniques on Angulated Implants Using the All-on-Four System
    de Avila, Erica Dorigatti
    Castanharo, Sabrina Maria
    Casalle, Nicole
    Vasconcelos, Juliano Alencar
    Mollo, Francisco de Assis, Jr.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 382 - 385
  • [48] Accuracy of new implant impression technique using dual arch tray and bite impression coping
    Lee, Shin-Eon
    Yang, Sung-Eun
    Lee, Cheol-Won
    Lee, Won-Sup
    Lee, Su Young
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (04) : 265 - 270
  • [49] A technique for splinting implant impression posts by using nylon sutures
    Kurian, Nirmal
    Gandhi, Nitasha
    Daniel, Angleena Y.
    Varghese, Kevin George
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (04) : 669 - 670
  • [50] Accuracy of Different Impression Techniques for Internal-Connection Implants
    Lee, Yun-Jung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 823 - 830