Implant Impression Techniques using Different Materials and Methods: A Review

被引:2
|
作者
Yasar, Muhammed Necati [1 ]
Cetinsahin, Cem [1 ]
Bayar, Omer [1 ]
Ozer, Hasan Yildrim [1 ]
机构
[1] Baskent Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Conventional impression; Custom tray; Digital dentistry; Intraoral digital impression; Slicone elastomers; EDENTULOUS PATIENTS; IN-VITRO; ACCURACY; ANGULATION; PROSTHESES; TIME; FIT;
D O I
10.7860/JCDR/2022/53057.16014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dental implants have emerged as the treatment of choice in for restoring missing teeth in situations that require functional and aesthetic replacements. Reproduction of the position and orientation of intraoral implants by means of an accurate impression in the definitive cast is the first step in achieving a passively fitting multi-implant supported prosthesis, to decrease the mechanical and biological complication of the prosthesis. The accuracy of the impression making procedure in the usage of osseointegrated implants used for the rehabilitation of fully and partially edentulous patients is a very important factor for the long-term success of dental implants. It has been reported that the precision of implant impressions is affected by various factors such as impression materials, impression technique, splinting of impression posts, impression level and depth, as well as the angle of the implants. Also, the incompatibility between implant and prosthesis, which may occur as a result of an incorrect impression, may cause problems such as screw loosening, screw fracture, loss of osseointegration and even implant fracture. Today, there are many articles and reviews about implant impressions. Although the authors found consistent results in many studies, there are differences of opinion on some issues. In general, polyether and additional type silicones were found to be successful in the conventional impression technique. Digital impression technique, on the other hand, has been found as successful as conventional measurement techniques in some studies. Controversial results have been obtained about the number of implants and their angulation. In general, the direct open tray splinted impression method is recommended for four or more implants, while there was no difference between the direct or indirect method for three or less implants.
引用
收藏
页码:ZE12 / ZE17
页数:6
相关论文
共 50 条
  • [31] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 : S412 - S415
  • [32] Implant Impression Techniques for the Edentulous Jaw: A Summary of Three Studies
    Stimmelmayr, Michael
    Beuer, Florian
    Edelhoff, Daniel
    Gueth, Jan-Frederik
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (02): : 146 - 150
  • [33] Strain Gauge Evaluation of Transfer Impression Techniques of Multiple Implant-Supported Prosthesis
    Nishioka, Renato Sussumu
    De Santis, Leandro Ruivo
    De Melo Nishioka, Gabriela Nogueira
    Kojima, Alberto Noriyuki
    Souza, Francisley Avila
    IMPLANT DENTISTRY, 2018, 27 (02) : 188 - 192
  • [34] The Accuracy of an Implant Impression Technique Using Digitally Coded Healing Abutments
    Eliasson, Alf
    Ortorp, Anders
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e30 - e38
  • [35] Accuracy of various impression materials and methods for two implant systems: An effect size study
    Schmidt, Alexander
    Haeussling, Teresa
    Rehmann, Peter
    Schaaf, Heidrun
    Woestmann, Bernd
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) : 245 - 251
  • [36] Implant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed tray techniques
    Osman, Motaz S.
    Ziada, Hassan M.
    Abubakr, Neamat H.
    Suliman, Ahmed M.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (1)
  • [37] Fit of Screw-Retained Fixed Implant Frameworks Fabricated by Different Methods: A Systematic Review
    Abduo, Jaafar
    Lyons, Karl
    Bennani, Vincent
    Waddell, Neil
    Swain, Michael
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (03) : 207 - 220
  • [38] The Effect of Splint Material Rigidity in Implant Impression Techniques
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Castanharo, Sabrina Maria
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (06) : 1153 - 1158
  • [39] Effect of Splinting in Accuracy of Two Implant Impression Techniques
    de Avila, Erica Dorigatti
    Moraes, Fernanda de Matos
    Castanharo, Sabrina Maria
    Del'Acqua, Marcelo Antonialli
    Mollo, Francisco de Assis, Jr.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 633 - 639
  • [40] Comparison of the Accuracy of Biomet 3i Encode Robocast Technology and Conventional Implant Impression Techniques
    Howell, Kent J.
    McGlumphy, Edwin A.
    Drago, Carl
    Knapik, Gregory
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 228 - 240