Implant Impression Techniques using Different Materials and Methods: A Review

被引:2
|
作者
Yasar, Muhammed Necati [1 ]
Cetinsahin, Cem [1 ]
Bayar, Omer [1 ]
Ozer, Hasan Yildrim [1 ]
机构
[1] Baskent Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Conventional impression; Custom tray; Digital dentistry; Intraoral digital impression; Slicone elastomers; EDENTULOUS PATIENTS; IN-VITRO; ACCURACY; ANGULATION; PROSTHESES; TIME; FIT;
D O I
10.7860/JCDR/2022/53057.16014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dental implants have emerged as the treatment of choice in for restoring missing teeth in situations that require functional and aesthetic replacements. Reproduction of the position and orientation of intraoral implants by means of an accurate impression in the definitive cast is the first step in achieving a passively fitting multi-implant supported prosthesis, to decrease the mechanical and biological complication of the prosthesis. The accuracy of the impression making procedure in the usage of osseointegrated implants used for the rehabilitation of fully and partially edentulous patients is a very important factor for the long-term success of dental implants. It has been reported that the precision of implant impressions is affected by various factors such as impression materials, impression technique, splinting of impression posts, impression level and depth, as well as the angle of the implants. Also, the incompatibility between implant and prosthesis, which may occur as a result of an incorrect impression, may cause problems such as screw loosening, screw fracture, loss of osseointegration and even implant fracture. Today, there are many articles and reviews about implant impressions. Although the authors found consistent results in many studies, there are differences of opinion on some issues. In general, polyether and additional type silicones were found to be successful in the conventional impression technique. Digital impression technique, on the other hand, has been found as successful as conventional measurement techniques in some studies. Controversial results have been obtained about the number of implants and their angulation. In general, the direct open tray splinted impression method is recommended for four or more implants, while there was no difference between the direct or indirect method for three or less implants.
引用
收藏
页码:ZE12 / ZE17
页数:6
相关论文
共 50 条
  • [21] Evaluation of Accuracy of Complete-Arch Multiple-Unit Abutment-Level Dental Implant Impressions Using Different Impression and Splinting Materials
    Buzayan, Muaiyed
    Baig, Mirza Rustum
    Yunus, Norsiah
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1512 - 1520
  • [22] In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 39 - 48
  • [23] The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study
    Menaga, V
    Chirom, Babina
    Gunadhar, Kangjam
    Priyadarshini, Shamurailatpam
    Nongthombam, Rajesh S.
    Manikandan, P.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [24] Evaluation of Implant Impression Accuracy Using Different Trays and Techniques with a 3D Superimposition Method
    Unsal, Gokce
    Caglar, Alper
    Tural, Mine
    Orhan, Metin
    Alkan, Ozer
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (04) : 595 - 602
  • [25] Accuracy of impressions with different impression materials in angulated implants
    Reddy, S.
    Prasad, K.
    Vakil, H.
    Jain, A.
    Chowdhary, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2013, 16 (03) : 279 - 284
  • [26] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [27] Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)
    Elshenawy, Enas A.
    Alam-Eldein, Ahmed M.
    Abd Elfatah, Fadel A.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [28] Assessing the Effect of Interimplant Distance and Angle on Different Impression Techniques
    Albayrak, Berkman
    Korkmaz, Ismail Hakki
    Wee, Alvin G.
    Sukotjo, Cortino
    Bayindir, Funda
    MACHINES, 2022, 10 (05)
  • [29] Accuracy of multiple implant impressions using different combinations of impression materials using closed tray technique: An in vitro study
    Deshmukh, Madhura
    Ahmed, Nabeel
    Maiti, Subhabrata
    Rajaraman, Vaishnavi
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2022, 13 (06) : 412 - 415
  • [30] Torque resistance of impression copings after direct implant impression: An in vitro evaluation of impression materials with and without adhesive
    Auroy, Pascal
    Nicolas, Emanuel
    Bedouin, Yvan
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (01): : 73 - 80