Performance and Applications of the CdTe- and Si-XPAD3 photon counting 2D detector

被引:9
作者
Medjoubi, K. [1 ]
Hustache, S. [1 ]
Picca, F. [1 ]
Berar, J. F. [2 ,3 ]
Boudet, N. [2 ,3 ]
Bompard, F. [4 ,5 ]
Breugnon, P. [4 ,5 ]
Clemens, J. -C. [4 ,5 ]
Dawiec, A. [4 ,5 ]
Delpierre, P. [4 ,5 ]
Dinkespiler, B. [4 ,5 ]
Godiot, S. [4 ,5 ]
Logier, J. -P. [4 ,5 ]
Menouni, M. [4 ,5 ]
Morel, C. [4 ,5 ]
Nicolas, M. [4 ,5 ]
Pangaud, P. [4 ,5 ]
Vigeolas, E. [4 ,5 ]
机构
[1] Synchrotron SOLEIL, F-91192 Gif Sur Yvette, France
[2] CNRS, D2AM CRG ESRF, F-38042 Grenoble 09, France
[3] CNRS, Inst Neel, F-38042 Grenoble 09, France
[4] Aix Marseille Univ, CPPM, Marseille, France
[5] CNRS, IN2P3, Marseille, France
关键词
X-ray detectors; Hybrid detectors; X-ray radiography and digital radiography (DR); HYBRID PIXEL DETECTOR; XPAD;
D O I
10.1088/1748-0221/6/01/C01080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The XPAD3 is the third generation of a single photon counting chip developed in collaboration by SOLEIL Synchrotron, the Institut Neel and the Centre de Physique de Particules de Marseille (CPPM). The chip contains 9600 pixels of 130 mu m side and a counting electronic chain with an adjustable low level threshold in each pixel. Imaging and detection performance (detective quantum efficiency, modulation transfer function and energy resolution) of the XPAD3 detectors hybridized with Si and CdTe sensors have been evaluated and compared using monochromatic synchrotron X-rays beam. A second version of the chip, optimized for pump-probe experiments, has been realized and successfully tested. Three 7.3 cm x 12.5 cm Si-XPAD3 imagers, composed of 8 silicon modules (7 chips per module) and one 2.1 cm x 3.1 cm CdTe-XPAD3 imager (4 chips) have been constructed and successfully used for synchrotron diffraction experiments and biomedical imaging.
引用
收藏
页数:10
相关论文
共 12 条
[1]   A 20 kpixels CdTe photon-counting imager using XPAD chip [J].
Basolo, S. ;
Berar, J. F. ;
Boudet, N. ;
Breugnon, P. ;
Chantepie, B. ;
Clemens, J. C. ;
Delpierre, P. ;
Dinkespiler, B. ;
Hustache, S. ;
Medjoubi, K. ;
Menouni, M. ;
Morel, C. ;
Pangaud, P. ;
Vigeolas, E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 589 (02) :268-274
[2]   Application of a hybrid pixel detector to powder diffraction [J].
Basolo, S. ;
Berar, J. -F. ;
Boudet, N. ;
Breugnon, P. ;
Caillot, B. ;
Clemens, J. -C. ;
Delpierre, P. ;
Dinkespiler, B. ;
Hustache, S. ;
Koudobine, I. ;
Meessen, Ch. ;
Menouni, M. ;
Mouget, C. ;
Palancher, H. ;
Pangaud, P. ;
Potheau, R. ;
Vigeolas, E. .
JOURNAL OF SYNCHROTRON RADIATION, 2007, 14 :151-157
[3]   XPAD3 hybrid pixel detector applications [J].
Berar, J-F. ;
Boudet, N. ;
Breugnon, P. ;
Caillot, B. ;
Chantepie, B. ;
Clemens, J-C. ;
Delpierre, P. ;
Dinkespiller, B. ;
Godiot, S. ;
Meessen, Ch. ;
Menouni, M. ;
Morel, C. ;
Pangaud, P. ;
Vigeolas, E. ;
Hustache, S. ;
Medjoubi, K. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :233-235
[4]   Imaging performance of the hybrid pixel detectors XPAD3-S [J].
Brunner, F. Cassol ;
Clemens, J. C. ;
Hemmer, C. ;
Morel, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06) :1773-1789
[5]  
Dainty J.C., 1974, Image Science: Principles, Analysis and Evaluation of Photographic-type Imaging Processes
[6]  
Dawiec A., 2009, IEEE ANIMMA, P1
[7]   XPAD: A photons counting pixel detector for material sciences and small-animal imaging [J].
Delpierre, P. ;
Basolo, S. ;
Berar, J. -F. ;
Bordesoule, M. ;
Boudet, N. ;
Breugnon, P. ;
Caillot, B. ;
Chantepie, B. ;
Clemens, J. C. ;
Dinkespiler, B. ;
Hustache-Ottini, S. ;
Meessen, C. ;
Menouni, M. ;
Morel, C. ;
Mouget, C. ;
Pangaud, P. ;
Potheau, R. ;
Vigeolas, E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01) :250-253
[8]   PILATUS: A single photon counting pixel detector for X-ray applications [J].
Henrich, B. ;
Bergamaschi, A. ;
Broennimann, C. ;
Dinapoli, R. ;
Eikenberry, E. F. ;
Johnson, I. ;
Kobas, M. ;
Kraft, P. ;
Mozzanica, A. ;
Schmitt, B. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :247-249
[9]   Detective quantum efficiency, modulation transfer function and energy resolution comparison between CdTe and silicon sensors bump-bonded to XPAD3S [J].
Medjoubi, Kadda ;
Bucaille, Thierry ;
Hustache, Stephanie ;
Berar, Jean-Francois ;
Boudet, Nathalie ;
Clemens, Jean-Claude ;
Delpierre, Pierre ;
Dinkespiler, Bernard .
JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 :486-495
[10]   Design and construction of the ClearPET/XPAD small animal PET/CT scanner [J].
Nicol, S. ;
Karkar, S. ;
Hemmer, C. ;
Dawiec, A. ;
Benoit, D. ;
Breugnon, P. ;
Dinkespiler, B. ;
Riviere, F. ;
Logier, J. -P. ;
Niclas, M. ;
Royon, J. ;
Meessen, C. ;
Cassol, F. ;
Clemens, J. -C. ;
Bonissent, A. ;
Debarbieux, F. ;
Vigeolas, E. ;
Delpierre, P. ;
Morel, C. .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :3311-3314