Improvement of Voltage Unbalance by Current Injection Based on Unbalanced Line Impedance in Distribution Network with PV System

被引:1
|
作者
Iioka, Daisuke [1 ]
Fujii, Takahiro [2 ]
Tanaka, Toshio [3 ]
Harimoto, Tsuyoshi [3 ]
Motoyama, Junpei [4 ]
Nagae, Daisuke [4 ]
机构
[1] Chubu Univ, Coll Engn, Dept Elect & Elect Engn, Kasugai, Aichi 4878501, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Elect Engn, Sendai, Miyagi 9808579, Japan
[3] Kyushu Elect Power Co Inc, Fukuoka 8158720, Japan
[4] Kyushu Elect Power Transmiss & Distribut Co Inc, Fukuoka 8100004, Japan
关键词
distributed power generation; photovoltaic systems; power quality; power distribution; power system analysis computing; power system measurements; reverse power flow; voltage unbalance; POWER-FLOW; REDUCTION; MITIGATION; INVERTER; FEEDERS; IMPACTS;
D O I
10.3390/en14238126
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, we have proposed a novel current injection determination method that improves the voltage unbalance based on the unbalanced line impedance in a distribution network with a large-capacity PV system. An increase in the unbalance of the distribution line voltage was observed owing to a large-scale reverse power flow. To visualize this phenomenon, the P-V curves were derived for each phase to indicate the increase in the voltage unbalance with respect to the reverse power flow. Based on the derived P-V curves, the effect of a current unbalance on the voltage unbalance was investigated. It was clarified that there is a current unbalance that can improve the voltage unbalance even if the line impedance is unbalanced. In other words, the current unbalance that can theoretically make the voltage unbalance zero could be expressed in terms of the symmetrical components of unbalanced line impedance. As an application of the proposed method, the effect of the mitigation of voltage unbalance was demonstrated by controlling single-phase reactors, whose numbers were determined by using the relationship between the unbalanced line current and unbalanced line impedance.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] A Quadrature Oscillator-Based DT for Accurate Estimation of Fundamental Load Current for PV System in Distribution Network
    Mathuria, Kanchan
    Hussain, Ikhlaq
    Singh, Bhim
    Kumar, Nishant
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (06) : 3324 - 3333
  • [22] Voltage and current profile improvement of a PV-integrated grid system employing sinusoidal current control strategy based unified power quality conditioner
    Senapati, Rudranarayan
    Illa, Vamsiram
    Swain, Sarat Chandra
    Senapati, Rajendra Narayan
    MATERIALS TODAY-PROCEEDINGS, 2021, 39 : 1866 - 1875
  • [23] Dynamic behavior of transformerless PV system on the short-term voltage stability of distribution network
    Islam, Monirul
    Nadarajah, Mithulananthan
    Hossain, M. J.
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [24] An Islanding Detection Method Based on Dual-Frequency Harmonic Current Injection Under Grid Impedance Unbalanced Condition
    Cai, Wen
    Liu, Bangyin
    Duan, Shanxu
    Zou, Changyue
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2013, 9 (02) : 1178 - 1187
  • [25] Current Mode Control of Dynamic Voltage Restorer for Power Quality Improvement in Distribution System
    Jayaprakash, P.
    Singh, Bhim
    Kothari, D. P.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 301 - +
  • [26] Three-Phase to Single-Phase Matrix Converter for Improvement of Three-Phase Voltage Unbalance in Distribution System
    Mizutani, Ryota
    Koizumi, Hirotaka
    Hirose, Kentaro
    Ishibashi, Kazunari
    ELECTRICAL ENGINEERING IN JAPAN, 2016, 195 (03) : 11 - 25
  • [27] RNN based Control Algorithm for Power Quality Improvement in PV Integrated Distribution System
    Saxena, Hemant
    Singh, Alka
    Rai, Jitendra Nath
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2021, 49 (9-10) : 849 - 859
  • [28] Internal Power Balancing of an MMC-Based Large-Scale PV System Under Unbalanced Voltage Sags
    Elsanabary, Ahmed
    Mekhilef, Saad
    Fadilah Ab Aziz, Nur
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (04) : 3729 - 3739
  • [29] Analysis of the Capacitor-Less D-STATCOM for Voltage Profile Improvement in Distribution Network With High PV Penetration
    Rohouma, Wesam
    Metry, Morcos
    Balog, Robert S.
    Peerzada, Aaqib Ahmad
    Begovic, Miroslav M.
    Zhou, Dao
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2022, 3 : 255 - 270
  • [30] Voltage unbalance assessment in a distribution system incorporated with renewable-based sources and electric vehicles in an uncertain environment
    Nandini, K. K.
    Sabhahit, Jayalakshmi N.
    Jadoun, Vinay Kumar
    IET RENEWABLE POWER GENERATION, 2024,