Paper-based assays for urine analysis

被引:61
|
作者
Lepowsky, Eric [1 ]
Ghaderinezhad, Fariba [1 ]
Knowlton, Stephanie [2 ]
Tasoglu, Savas [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Connecticut, Dept Mech Engn, Storrs, CT 06269 USA
[2] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[3] Univ Connecticut, Inst Mat Sci, Storrs, CT 06269 USA
[4] Univ Connecticut, Inst Collaborat Hlth Intervent & Policy InCHIP, Storrs, CT 06269 USA
[5] Univ Connecticut, Connecticut Inst Brain & Cognit Sci, Storrs, CT 06269 USA
来源
BIOMICROFLUIDICS | 2017年 / 11卷 / 05期
基金
美国国家科学基金会;
关键词
ALBUMIN EXCRETION RATE; LATERAL FLOW ASSAY; LOW-COST; MICROFLUIDIC DEVICES; CREATININE RATIO; REAGENT STRIP; MICROCHIP ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; COLORIMETRIC DETECTION; LACTATE EXCRETION;
D O I
10.1063/1.4996768
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A transformation of the healthcare industry is necessary and imminent: hospital-centered, reactive care will soon give way to proactive, person-centered care which focuses on individuals' well-being. However, this transition will only be made possible through scientific innovation. Next-generation technologies will be the key to developing affordable and accessible care, while also lowering the costs of healthcare. A promising solution to this challenge is low-cost continuous health monitoring; this approach allows for effective screening, analysis, and diagnosis and facilitates proactive medical intervention. Urine has great promise for being a key resource for health monitoring; unlike blood, it can be collected effortlessly on a daily basis without pain or the need for special equipment. Unfortunately, the commercial rapid urine analysis tests that exist today can only go so far-this is where the promise of microfluidic devices lies. Microfluidic devices have a proven record of being effective analytical devices, capable of controlling the flow of fluid samples, containing reaction and detection zones, and displaying results, all within a compact footprint. Moving past traditional glass-and polymer-based microfluidics, paper-based microfluidic devices possess the same diagnostic ability, with the added benefits of facile manufacturing, low-cost implementation, and disposability. Hence, we review the recent progress in the application of paper-based microfluidics to urine analysis as a solution to providing continuous health monitoring for proactive care. First, we present important considerations for point-of-care diagnostic devices. We then discuss what urine is and how paper functions as the substrate for urine analysis. Next, we cover the current commercial rapid tests that exist and thereby demonstrate where paper-based microfluidic urine analysis devices may fit into the commercial market in the future. Afterward, we discuss various fabrication techniques that have been recently developed for paper-based microfluidic devices. Transitioning from fabrication to implementation, we present some of the clinically implemented urine assays and their importance in healthcare and clinical diagnosis, with a focus on paper-based microfluidic assays. We then conclude by providing an overview of select biomarker research tailored towards urine diagnostics. This review will demonstrate the applicability of paper-based assays for urine analysis and where they may fit into the commercial healthcare market. Published by AIP Publishing.
引用
收藏
页数:34
相关论文
共 50 条
  • [21] Paper-based microfluidics for food safety and quality analysis
    Nilghaz, Azadeh
    Mousavi, Seyed Mandi
    Li, Miaosi
    Tian, Junfei
    Cao, Rong
    Wang, Xungai
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2021, 118 : 273 - 284
  • [22] Engineering strategies for enhancing the performance of electrochemical paper-based analytical devices
    Baharfar, Mahroo
    Rahbar, Mohammad
    Tajik, Mohammad
    Liu, Guozhen
    BIOSENSORS & BIOELECTRONICS, 2020, 167
  • [23] Microfluidic paper-based devices for bioanalytical applications
    Santhiago, Murilo
    Nery, Emilia W.
    Santos, Glauco P.
    Kubota, Lauro T.
    BIOANALYSIS, 2014, 6 (01) : 89 - 106
  • [24] Sensing approaches on paper-based devices: a review
    Nery, Emilia W.
    Kubota, Lauro T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (24) : 7573 - 7595
  • [25] Detection of heavy metal by paper-based microfluidics
    Lin, Yang
    Gritsenko, Dmitry
    Feng, Shaolong
    Teh, Yi Chen
    Lu, Xiaonan
    Xu, Jie
    BIOSENSORS & BIOELECTRONICS, 2016, 83 : 256 - 266
  • [26] Recent Developments in Paper-Based Microfluidic Devices
    Cate, David M.
    Adkins, Jaclyn A.
    Mettakoonpitak, Jaruwan
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2015, 87 (01) : 19 - 41
  • [27] Fabrication and Operation of Paper-Based Analytical Devices
    Jiang, Xiao
    Fan, Z. Hugh
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 9, 2016, 9 : 203 - 222
  • [28] Mixed thread/paper-based microfluidic chips as a platform for glucose assays
    Gonzalez, Ariana
    Estala, Lissette
    Gaines, Michelle
    Gomez, Frank A.
    ELECTROPHORESIS, 2016, 37 (12) : 1685 - 1690
  • [29] Paper-based microfluidic devices for glucose assays employing a metal-organic framework (MOF)
    Ilacas, Grenalynn C.
    Basa, Alexis
    Nelms, Katherine J.
    Sosa, Joshua D.
    Liu, Yangyang
    Gomez, Frank A.
    ANALYTICA CHIMICA ACTA, 2019, 1055 : 74 - 80
  • [30] Thermally programmable time delay switches for multi-step assays in paper-based microfluidics
    Atabakhsh, Saeed
    Abbasali, Hossein Haji
    Ashtiani, Shahin Jafarabadi
    TALANTA, 2024, 271