Clinical applications of point-of-care ultrasound in brain injury: a narrative review

被引:11
作者
Dinsmore, M. [1 ]
Venkatraghavan, L. [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Toronto Western Hosp, Dept Anaesthesia & Pain Management, Toronto, ON, Canada
关键词
brain injury; intracranial pressure; optic nerve sheath diameter; point-of-care ultrasound; transcranial Doppler; OPTIC-NERVE SHEATH; ANEURYSMAL SUBARACHNOID HEMORRHAGE; COLOR-CODED SONOGRAPHY; TRANSCRANIAL DOPPLER; INTRACEREBRAL HEMORRHAGE; CEREBRAL AUTOREGULATION; INTRACRANIAL-PRESSURE; PULSATILITY INDEX; MIDLINE SHIFT; FLOW-VELOCITY;
D O I
10.1111/anae.15604
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The use of point-of-care ultrasound has increased considerably over the last two decades. It has become a readily available, non-invasive bed-side modality for the rapid diagnosis and management of patients in various settings. Point-of-care ultrasound for assessing the heart, lung, abdomen, airway and vascular systems is now well established. Transcranial Doppler ultrasound for assessing cerebral blood flow has been in use for many years. In recent years, brain ultrasonography has been shown to be a powerful tool in the rapid bed-side assessment of cerebral haemodynamics and structural pathology. Brain ultrasound has been shown to be useful in both the emergency department and neurocritical care setting for the non-invasive assessment of raised intracranial pressure, cerebral autoregulation and diagnosis of intracranial haematoma and other space-occupying lesions. Point-of-care ultrasound is an important alternative technique to routine imaging and invasive monitoring techniques, and results are comparable. Competence is easily attainable without formal radiology training. With technological advancement, applications for the use of brain ultrasound continue to grow. This review discusses the clinical use of point-of-care ultrasound in the diagnosis and management of brain injury.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 64 条
[51]   Transcranial Doppler: a stethoscope for the brain-neurocritical care use [J].
Robba, Chiara ;
Cardim, Danilo ;
Sekhon, Mypinder ;
Budohoski, Karol ;
Czosnyka, Marek .
JOURNAL OF NEUROSCIENCE RESEARCH, 2018, 96 (04) :720-730
[52]   Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: A prospective observational study [J].
Robba, Chiara ;
Cardim, Danilo ;
Tajsic, Tamara ;
Pietersen, Justine ;
Bulman, Michael ;
Donnelly, Joseph ;
Lavinio, Andrea ;
Gupta, Arun ;
Menon, David K. ;
Hutchinson, Peter J. A. ;
Czosnyka, Marek .
PLOS MEDICINE, 2017, 14 (07)
[53]   Transcranial Ultrasound from Diagnosis to Early Stroke Treatment - Part 2: Prehospital Neurosonography in Patients with Acute Stroke - The Regensburg Stroke Mobile Project [J].
Schlachetzki, Felix ;
Herzberg, Moriz ;
Hoelscher, Thilo ;
Ertl, Michael ;
Zimmermann, Markus ;
Ittner, Karl Peter ;
Pels, Hendrik ;
Bogdahn, Ulrich ;
Boy, Sandra .
CEREBROVASCULAR DISEASES, 2012, 33 (03) :262-271
[54]   Quantification of Optic Nerve and Sheath Diameter by Transorbital Sonography: A Systematic Review and Metanalysis [J].
Schroeder, Christoph ;
Katsanos, Aristeidis H. ;
Richter, Daniel ;
Tsivgoulis, Georgios ;
Gold, Ralf ;
Krogias, Christos .
JOURNAL OF NEUROIMAGING, 2020, 30 (02) :165-174
[55]   Dislocation of the third ventricle due to space-occupying stroke evaluated by transcranial duplex sonography [J].
Seidel, G ;
Gerriets, T ;
Kaps, M ;
Missler, U .
JOURNAL OF NEUROIMAGING, 1996, 6 (04) :227-230
[56]  
Seidel G, 1995, J Neuroimaging, V5, P105
[57]   Transcranial Doppler as a Routine in the Treatment of Vasospasm Following Subarachanoid Hemorrhage (SAH) [J].
Simm, Renata F. ;
Pires de Aguiar, Paulo H. ;
de Oliveira Lima, M. ;
Paiva, Bernardo L. .
CEREBRAL VASOSPASM: NEUROVASCULAR EVENTS AFTER SUBARACHNOID HEMORRHAGE, 2013, 115 :75-+
[58]   Third ventricle midline shift due to spontaneous supratentorial intracerebral hemorrhage evaluated by transcranial color-coded sonography [J].
Tang, SC ;
Huang, SJ ;
Jeng, JS ;
Yip, PK .
JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (02) :203-209
[59]   Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients [J].
Tayal, Vivek S. ;
Neulander, Matthew ;
Norton, H. James ;
Foster, Troy ;
Saunders, Timothy ;
Blaivas, Michael .
ANNALS OF EMERGENCY MEDICINE, 2007, 49 (04) :508-514
[60]   Great auricular nerve blockade using high resolution ultrasound: a volunteer study [J].
Thallaj, A. ;
Marhofer, P. ;
Moriggl, B. ;
Delvi, B. M. ;
Kettner, S. C. ;
Almajed, M. .
ANAESTHESIA, 2010, 65 (08) :836-840