Development of a digital micromirror spectrometer for analytical atomic spectrometry

被引:15
作者
Batchelor, JD [1 ]
Jones, BT [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
关键词
D O I
10.1021/ac980597p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A digital micromirror device (DMD) has been incorporated into a novel spectrometer for use in analytical atomic spectrometry, The device can be taken from a commercial computer projector. A protective glass window covering the DMD chip limits the viewable wavelengths to the visible range, The DMD is used to project an image of the light source onto the exit plane of a flat-held spectrograph. A single photomultiplier tube is used for detection. The high switching rate of the micromirrors (15 mu s) enables rapid full-spectrum capture, wavelength-modulation, source-modulation, fast narrow-wavelength window scans, and rapid-wavelength "jumping." Calcium, sodium, and potassium have been determined in several standard reference materials (tomato leaves, bovine liver, rice flour, total diet) by flame atomic absorption and emission spectrometry, Absorption sensitivities for each element are near the 0.02 mu g/mL level, and detection limits for both absorption and emission are near the 0.01 mu g/mL level. Elemental recoveries were within 10% of certified values for most reference materials.
引用
收藏
页码:4907 / 4914
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 1982, ANAL METHODS ATOMIC
[2]   Echelle spectrometers and charge-coupled devices [J].
BeckerRoss, H ;
Florek, SV .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) :1367-1375
[3]   A SQUARE-WAVE WAVELENGTH MODULATION SYSTEM FOR AUTOMATIC BACKGROUND CORRECTION IN CARBON FURNACE ATOMIC EMISSION-SPECTROMETRY [J].
BEZUR, L ;
MARSHALL, J ;
OTTAWAY, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (06) :787-805
[4]   DOUBLE MODULATION - OPTICAL SCANNING AND MECHANICAL CHOPPING - IN ATOMIC-ABSORPTION SPECTROMETRY USING A CONTINUUM SOURCE [J].
ELSER, RC ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1972, 44 (04) :698-+
[5]   APPLICATIONS OF CHARGE-TRANSFER DEVICES IN SPECTROSCOPY [J].
EPPERSON, PM ;
SWEEDLER, JV ;
BILHORN, RB ;
SIMS, GR ;
DENTON, MB .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :A327-&
[6]   JOINT-TRANSFORM CORRELATOR SYSTEMS USING DEFORMABLE-MIRROR SPATIAL LIGHT MODULATORS [J].
FLORENCE, JM .
OPTICS LETTERS, 1989, 14 (07) :341-343
[7]   LASER-EXCITED ATOMIC FLUORESCENCE FLAME SPECTROMETRY AS AN ANALYTICAL METHOD [J].
FRASER, LM ;
WINEFORD.JD .
ANALYTICAL CHEMISTRY, 1972, 44 (08) :1444-&
[8]  
Harnly J. M., 1977, Analytical Chemistry, V49, P2187, DOI 10.1021/ac50022a020
[9]   Solid state array detectors for analytical spectrometry [J].
Harnly, JM ;
Fields, RE .
APPLIED SPECTROSCOPY, 1997, 51 (09) :A334-A351
[10]   BACKGROUND-CORRECTED SIMULTANEOUS MULTIELEMENT ATOMIC-ABSORPTION SPECTROMETER [J].
HARNLY, JM ;
OHAVER, TC ;
GOLDEN, B ;
WOLF, WR .
ANALYTICAL CHEMISTRY, 1979, 51 (12) :2007-2014