Determination of heparin on intraocular lens surfaces by ion chromatography

被引:17
作者
Ander, B [1 ]
Karlsson, A [1 ]
Öhrlund, Å [1 ]
机构
[1] Pharmacia AB, Marketed Prod Support, S-75182 Uppsala, Sweden
关键词
lens; intraocular; heparin;
D O I
10.1016/S0021-9673(01)00661-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective method has been developed for the determination of heparin on heparin coated PMMA, poly(methyl methacrylate), intraocular lenses. Heparin was hydrolysed to glucosamine and glucuronic acid, and the content of glucosamine was determined using ion chromatography with pulsed amperometric detection. In order to verify that a complete hydrolysis was obtained for the heparin on the coated intraocular lenses, electron spectroscopy for chemical analysis (ESCA) was used for analysing traces of sulphur on the lens surfaces. The sensitivity of the method allows quantitative determination of 150 ng of heparin on one individual lens. The new method was compared to a standard spectrophotometric method, measuring the colour intensity of a heparin toluidine blue complex. Correlation between the methods was shown for samples prepared from PMMA lenses coated with different amounts of heparin. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 7 条
[1]   A NEW NON-THROMBOGENIC SURFACE PREPARED BY SELECTIVE COVALENT BINDING OF HEPARIN VIA A MODIFIED REDUCING TERMINAL RESIDUE [J].
LARM, O ;
LARSSON, R ;
OLSSON, P .
BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1983, 11 (2-3) :161-173
[2]   Decreased incidence of arterial thrombosis using heparin-bonded intraaortic balloons [J].
Lazar, HL ;
Bao, YS ;
Rivers, S ;
Treanor, PR ;
Shemin, RJ .
ANNALS OF THORACIC SURGERY, 1999, 67 (02) :446-449
[3]   A prospective randomized trial of Duraflo II heparin-coated circuits in cardiac reoperations [J].
McCarthy, PM ;
Yared, JPP ;
Foster, RC ;
Ogella, DA ;
Borsh, JA ;
Cosgrove, DM .
ANNALS OF THORACIC SURGERY, 1999, 67 (05) :1268-1273
[4]   Thrombogenicity of deflated intraaortic balloon: Impact of heparin coating [J].
Mueller, XM ;
Tevaearai, HT ;
Hayoz, T ;
von Segesser, LK .
ARTIFICIAL ORGANS, 1999, 23 (02) :195-198
[5]   Temporary shunt system with a heparin-coated inner surface for interruption of cerebral circulation: Experiments in primates [J].
Tenjin, H ;
Ueda, S ;
Johnson, CM .
NEUROSURGERY, 1998, 43 (02) :312-315
[6]   DIAGNOSTIC METHODS FOR THE DETERMINATION OF IDURONIC ACID IN OLIGOSACCHARIDES [J].
WHITFIELD, DM ;
STOJKOVSKI, S ;
PANG, H ;
BAPTISTA, J ;
SARKAR, B .
ANALYTICAL BIOCHEMISTRY, 1991, 194 (02) :259-267
[7]  
YGGE J, 1990, OPHTHALMOLOGY, V97, P1216