Development of new Ti-Fe-Ta and Ti-Fe-Ta-Zr system alloys for biomedical applications

被引:13
|
作者
Kuroda, D [1 ]
Kawasaki, H
Hiromoto, S
Hanawa, T
机构
[1] Natl Inst Mat Sci, Ctr Biomat, Tsukuba, Ibaraki 3050044, Japan
[2] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Div Biomat,Dept Met, Chiyoda Ku, Tokyo 1010062, Japan
关键词
beta-type titanium alloy; non-toxic element; mechanical properties; microstructure; polarization behavior; biomaterials;
D O I
10.2320/matertrans.46.1532
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
beta-type titanium alloys consisting of non-toxic elements, Ti-8Fe-8Ta, Ti-8Fe-8Ta-4Zr, and Ti-10Fe-l0Ta-4Zr, were newly designed and developed for biomedical applications. Changes in the mechanical properties of the designed alloys with various heat treatments were discussed on the basis of the resultant microstructures. In addition, the corrosion resistance of the designed alloys was evaluated by polarization test in Hanks' solution. Conventional biomedical titanium and a titanium alloy, cp-Ti and Ti-6Al-4V ELI, respectively, were also polarized for comparison. The structural phase of the designed alloys after cold rolling and solution treatment was only the beta phase. The ultimate tensile strength and elongation to fracture of Ti-8Fe-8Ta, Ti-8Fe-8Ta-4Zr, and Ti-10Fe-10Ta-4Zr after solution treatment were 1066 MPa and 10 %, 1051 MPa and 10 %, and 1092 MPa and 6 %, respectively. Ti-8Fe-8Ta and Ti-8Fe-8Ta-4Zr have higher strength than conventional biomedical titanium alloys, such as Ti-6AI-4V ELI, Ti-6Al-7Nb, and Ti-13Nb-13Zr. In addition, the elongations to fracture of Ti-8Fe-8Ta and Ti-8Fe-8Ta-4Zr were equal to those of Ti-6AI-4V ELI and Ti-6AI-7Nb. The designed alloys and conventional biomedical titanium alloys were spontaneously passivated in Hanks' solution. The cur-rent density of cp-Ti and Ti-6AI-4V ELI was increased at a potential above 2.5 V. On the other hand, the current density of the designed alloys was abruptly increased at a potential above 3.5 V. This indicated that the designed alloys have an advantage over cp-Ti and Ti-6AI-4V ELI, namely, high resistance to pitting corrosion in biological environments. Therefore, the new P-type titanium alloys designed in this study, Ti-8Fe-8Ta and Ti-8Fe-8Ta-4Zr, are expected to have good properties as biomaterials.
引用
收藏
页码:1532 / 1539
页数:8
相关论文
共 50 条
  • [11] Aging Response of Ti-25Nb-10Ta-1Zr-0.2Fe Alloys for Biomedical Application
    Lian Caihao
    Yi Danqing
    Liu Huiqun
    Yang Fuliang
    Tian Liang
    RARE METAL MATERIALS AND ENGINEERING, 2011, 40 (09) : 1633 - 1637
  • [12] Bulk and porous metastable beta Ti-Nb-Zr(Ta) alloys for biomedical applications
    Brailovski, V.
    Prokoshkin, S.
    Gauthier, M.
    Inaekyan, K.
    Dubinskiy, S.
    Petrzhik, M.
    Filonov, M.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (03): : 643 - 657
  • [13] Development of Ti-Zr alloys by powder metallurgy for biomedical applications
    Amigo-Mata, Angelica
    Haro-Rodriguez, Montserrat
    Vicente-Escuder, Angel
    Amigo-Borras, Vicente
    POWDER METALLURGY, 2022, 65 (01) : 31 - 38
  • [14] Effect of Aging Temperature on Microstructure and Mechanical Properties of Ti-Nb-Ta-Zr-Fe Alloy for Biomedical Applications
    Xu, Y. F.
    Yi, D. Q.
    Liu, H. Q.
    Wang, B.
    Yang, F. L.
    TI-2011: PROCEEDINGS OF THE 12TH WORLD CONFERENCE ON TITANIUM, VOL III, 2012, : 2126 - 2129
  • [15] Effects of cold deformation on microstructure, texture evolution and mechanical properties of Ti-Nb-Ta-Zr-Fe alloy for biomedical applications
    Xu, Y. F.
    Yi, D. Q.
    Liu, H. Q.
    Wu, X. Y.
    Wang, B.
    Yang, F. L.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2012, 547 : 64 - 71
  • [16] Microstructural and mechanical characterization of biomedical Ti-Nb-Zr(-Ta) alloys
    Elias, L. M.
    Schneider, S. G.
    Schneider, S.
    Silva, H. M.
    Malvisi, E.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2006, 432 (1-2): : 108 - 112
  • [17] Mechanical properties of binary Ti-Ta alloys for biomedical applications
    Zhou, YL
    Niinomi, M
    Akahori, T
    DESIGNING, PROCESSING AND PROPERTIES OF ADVANCED ENGINEERING MATERIALS, PTS 1 AND 2, 2004, 449-4 : 1089 - 1092
  • [18] Increasing strength of a biomedical Ti-Nb-Ta-Zr alloy by alloying with Fe, Si and O
    Strasky, Josef
    Harcuba, Petr
    Vaclavova, Kristina
    Horvath, Klaudia
    Landa, Michal
    Srba, Ondrej
    Janecek, Milog
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 71 : 329 - 336
  • [19] Preparation, structural and microstructural characterization of Ti-25Ta-10Zr alloy for biomedical applications
    Quadros, Fernanda de Freitas
    Bazaglia Kuroda, Pedro Akira
    Jorge Sousa, Karolyne dos Santos
    Goto Donato, Tatiani Ayako
    Grandini, Carlos Roberto
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2019, 8 (05): : 4108 - 4114
  • [20] Design and properties of novel Ti-Zr-Hf-Nb-Ta high-entropy alloys for biomedical applications
    Yang, Wei
    Pang, Shujie
    Liu, Ying
    Wang, Qing
    Liaw, Peter K.
    Zhang, Tao
    INTERMETALLICS, 2022, 141