The removal of the opaque crystalline lens in cataract surgery and its replacement by an artificial lens has become the most successful surgical intervention in the history of medicine. Modern intraocular lenses, today's micro-incision approach and high-end measurement and computational techniques provide restoration of good visual acuity in the majority of cases. Patients with problem eyes not allowing standard procedures for intraocular lens power calculation require special attention. Among them are highly ametropic subjects with very short or long eyes or patients, whose corneal structures, are different from normal due to preceding refractive surgery. The special problems for measurement and lens power calculations in these eyes are dealt with in detail. Based on hitherto unpublished clinical data, causes and possible solutions for the existing problems are discussed. Generally, the best available measurement techniques should be applied in these cases. With respect to the algorithms used it has to be made sure that no additional errors are introduced by the algorithms themselves. The popular SRK II formula should therefore not be used any more. If errors are minimized this way, gross postoperative refractive surprises should be avoided even in problem eyes.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 42 条
[1]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[2]  
Brian GR, 2000, OPHTHALMOL CLIN N AM, V13, P141
[3]  
CURTIN BJ, AM J OPHTH, V71, P42
[4]  
*EUR STAND, 119792 ISO
[5]   Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia - A standardized approach [J].
Feiz, V ;
Mannis, MJ ;
Garcia-Ferrer, F ;
Kandavel, G ;
Darlington, JK ;
Kim, E ;
Caspar, J ;
Wang, JL ;
Wang, W .
CORNEA, 2001, 20 (08) :792-797
[6]   Corneal power after refractive surgery for myopia: Contact lens method [J].
Haigis, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07) :1397-1411
[7]  
Haigis W, 2002, DEV OPHTHALMOL, V34, P119
[8]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[9]  
HAIGIS W, 1999, BENEFITS USING 3 CON
[10]  
HAIGIS W, 2005, KLIN MONATSBL AUGENH, V222, P24