Revision surgery of proximally modular hip stems

被引:0
作者
Cameron, HU [1 ]
机构
[1] Orthopaed & Arthrit Inst, Toronto, ON M4Y 1H1, Canada
来源
ORTHOPADE | 2001年 / 30卷 / 05期
关键词
modularity; stem revision; S-Rom;
D O I
10.1007/s001320050610
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The introduction of a proximally modular hip stem has greatly simplified difficult hip surgery. The long-term results of revision surgery indicate that the majority of revision cases can be handled with a proximal ingrowth implant,which helps speed bone recovery and simplifies re-revision if it is required. To date no particular downside has been noted as a result of the use of a modular stem.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 50 条
  • [41] Are Corrosion and Material Loss a Threat for Titanium-Titanium Tapers in Total Hip Arthroplasty Modular Acetabular Components?
    Spece, Hannah
    Ouellette, Eric S.
    Klein, Gregg R.
    Mont, Michael A.
    Kurtz, Steven M.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (06) : 1602 - 1608
  • [42] Clinical and radiological outcomes and analysis of failures of modular revisions stems at long-term follow-up: a systematic review and meta-analysis
    Saracco, Michela
    Ciriello, Vincenzo
    Fidanza, Andrea
    Logroscino, Giandomenico
    ANNALS OF JOINT, 2024, 9 : 1 - 10
  • [43] Mix and Match Use of Revision Universal Head-Neck Adapters in Hip Arthroplasty: A Complications and Survival Analysis of 306 Cases
    Valentini, Marisa
    Thaller, Alexander
    Ruckenstuhl, Paul
    Sadoghi, Patrick
    Leithner, Andreas
    Leitner, Lukas
    JOURNAL OF ARTHROPLASTY, 2024, 39 (10) : 2561 - 2568
  • [44] Primary cementless total hip arthroplasty using a modular femoral component - A minimum 6-year follow-up
    Tanzer, M
    Chan, S
    Brooks, CE
    Bobyn, JD
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08) : 64 - 70
  • [45] A Modified Modular Stem in Primary Total Hip Arthroplasty for Developmental Dysplasia of the Hip: Average 11-year Follow-Up in Cases With Previously Reported 3-year Clinical Results
    Matsushita, Yohei
    Otani, Takuya
    Hayama, Tetsuo
    Fujii, Hideki
    Kawaguchi, Yasuhiko
    Saito, Mitsuru
    JOURNAL OF ARTHROPLASTY, 2022, 37 (09) : 1832 - 1838
  • [46] Significantly Reduced Leg Length Discrepancy and Increased Femoral Offset by Application of a Head-Neck Adapter in Revision Total Hip Arthroplasty
    Woelfle, Julia V.
    Fraitzl, Christian R.
    Reichel, Heiko
    Wernerus, Dirk
    JOURNAL OF ARTHROPLASTY, 2014, 29 (06) : 1301 - 1307
  • [47] Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup
    Spranz, David
    Mueller, Lisa-Marie
    Trefzer, Raphael
    Hetto, Pit
    Nees, Timo
    Renkawitz, Tobias
    Walker, Tilman
    Reiner, Tobias
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (12) : 3083 - 3090
  • [48] High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion
    Nahhas, Cindy R.
    Yi, Paul H.
    Moric, Mario
    Puri, Rajeev
    Jacobs, Joshua J.
    Sporer, Scott M.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (07) : 1395 - 1399
  • [49] Method of Characterizing Fretting and Corrosion at the Various Taper Connections of Retrieved Modular Components from Metal-on-Metal Total Hip Arthroplasty
    Higgs, Genymphas B.
    Hanzlik, Josa A.
    MacDonald, Daniel W.
    Kane, William M.
    Day, Judd S.
    Klein, Gregg R.
    Parvizi, Javad
    Mont, Michael A.
    Kraay, Matthew J.
    Martell, John M.
    Gilbert, Jeremy L.
    Rimnac, Clare M.
    Kurtz, Steven M.
    METAL-ON-METAL TOTAL HIP REPLACEMENT DEVICES, 2013, 1560 : 146 - 156
  • [50] Influence of geometry and materials on the axial and torsional strength of the head-neck taper junction in modular hip replacements: A finite element study
    Fallahnezhad, Khosro
    Farhoudi, Hamidreza
    Oskouei, Reza H.
    Taylor, Marlz
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 60 : 118 - 126