Coherent error study in a retarding field energy analyzer

被引:2
|
作者
Cui, Y [1 ]
Zou, Y [1 ]
Reiser, M [1 ]
Kishek, RA [1 ]
Haber, I [1 ]
Bernal, S [1 ]
O'Shea, PG [1 ]
机构
[1] Univ Maryland, Inst Res Elect & Appl Phys, College Pk, MD 20742 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2005年 / 544卷 / 1-2期
关键词
energy spread; electron beam; energy analyzer;
D O I
10.1016/j.nima.2005.01.286
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel cylindrical retarding electrostatic field energy analyzer for low-energy beams has been designed, simulated, and tested with electron beams of several keV, in which space charge effects play an important role. A cylindrical focusing electrode is used to overcome the beam expansion inside the device due to space-charge forces, beam emittance. etc. In this paper, we present the coherent error analysis for this energy analyzer with beam envelope equation including space charge and ernittance effects. The study shows that this energy analyzer can achieve very high resolution (with relative error of around 10(-5)) if taking away the coherent errors by using proper focusing voltages. The theoretical analysis is compared with experimental results. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 50 条
  • [1] A SIMPLE CYLINDRICAL RETARDING-FIELD ENERGY ANALYZER
    FUJII, Y
    ISHIGURO, E
    KITADA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 (10): : 2176 - 2179
  • [2] Impact of selective ion transmission on measurement by retarding field analyzer
    Takahashi, H.
    Seino, T.
    Nishimura, R.
    Yoshimura, K.
    Kanno, A.
    Hara, T.
    Takahashi, Y.
    Kagaya, S.
    Matsuyama, A.
    Hayashi, Y.
    Tobita, K.
    PHYSICS OF PLASMAS, 2023, 30 (05)
  • [3] The influence of impurities on ion temperature measured by a retarding field analyzer
    Shao, J.
    Liu, Hai
    Xu, Yuhong
    Huang, Jie
    Liu, Haifeng
    Wang, Xianqu
    Zhang, Xin
    Cheng, Jun
    Tang, Changjian
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (02)
  • [4] Simulation Study of a Small Deflection Energy Analyzer for Thermospheric Sounding Field
    Li, T.
    Li, R. C.
    Jiao, Z. L.
    Wang, G. D.
    Qiao, L.
    2018 EIGHTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2018), 2018, : 910 - 914
  • [5] Scanning retarding field analyzer for plasma profile measurements in the boundary of the Alcator C-Mod tokamak
    Brunner, D.
    LaBombard, B.
    Ochoukov, R.
    Whyte, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (03):
  • [6] Beam interaction measurements with a Retarding Field Analyzer in a high-current high-vacuum positively charged particle accelerator
    Covo, M. Kireeff
    Molvik, A. W.
    Friedman, A.
    Barnard, J. J.
    Seidl, P. A.
    Logan, B. G.
    Baca, D.
    Vujic, J. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 577 (1-2): : 139 - 145
  • [7] Two-electrode charged particle energy analyzer with a quasi-linear electrostatic field
    Fishkova, T. Ya.
    TECHNICAL PHYSICS, 2012, 57 (05) : 730 - 732
  • [8] Two-electrode charged particle energy analyzer with a quasi-linear electrostatic field
    T. Ya. Fishkova
    Technical Physics, 2012, 57 : 730 - 732
  • [9] Work function measurements using a field emission retarding potential technique
    Hamanaka, M. H. M. O.
    Dall'Agnol, F. F.
    Pimentel, V. L.
    Mammana, V. P.
    Tatsch, P. J.
    den Engelsen, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (03):
  • [10] Design and aberration study of a new miniature energy analyzer with correctors in a scanning electron microscope
    Noh, Hyeongrae
    Cho, Boklae
    Kim, Jeehoon
    Ogawa, Takashi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 917 : 9 - 17