Thermodynamics of Vanadium redox flow batteries electrochemical and calorimetric investigations

被引:19
作者
Heintz, A
Illenberger, C
机构
[1] Univ Rostock, Phys Chem Abt, D-18051 Rostock, Germany
[2] Fa Kiefer & Veittinger, D-68161 Mannheim, Germany
来源
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS | 1998年 / 102卷 / 10期
关键词
electrochemistry; redox flow batteries; solutions; thermodynamics;
D O I
10.1002/bbpc.199800009
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Thermodynamic properties of the so-called All-Vanadium battery used as energy storage system and other vanadium redox systems related to the All-Vanadium battery have been studied. An electrochemical cell has been constructed to measure the equilibrium cell voltages as function of the degree of charging in the temperature range from 278 K to 323 K. The first system studied is the disproportion reaction of VO2+ ions with the two half cell reactions VO2++H2O reversible arrow VO2++2H(+)+e(-) and VO2++2H(+)+e(-)reversible arrow V3++H2O. The second system is the All-Vanadium battery reaction with the two half cell reactions VO2++H2O reversible arrow VO(2)(+)2H(+)+e(-) and V3++e(-)reversible arrow V2+. The third system is the disproportion reaction of V3+ ions with the half cell reactions V3++H2O reversible arrow VO2++2H(+)+e(-) and V3++e(-) reversible arrow V2+. The molar reaction Gibbs energy, the molar reaction enthalpy, and the molar reaction entropy of each system has been obtained from these data. Additionally the molar reaction enthalpy of the two disproportion reactions and of the reaction V2++2VO(2)(+)+2H(+) --> 3VO(2+)+H2O has been measured directly by titration calorimetry. The results agree with those obtained from the electrochemical data for the disproportion reactions. No direct calorimetric measurements of the molar reaction enthalpy of the All-Vanadium battery reaction is possible, but the sum of the molar reaction enthalpies of the two disproportion reactions gives the molar reaction enthalpy of the All-Vanadium battery reaction. Comparison with the electrochemically determined molar reaction enthalpy of the All-Vanadium battery reaction shows good agreement indicating satisfying thermodynamic consistency of the whole procedure.
引用
收藏
页码:1401 / 1409
页数:9
相关论文
共 25 条
  • [1] ALIMARIN IP, 1962, RUSS J INORG CHEM, V7, P152
  • [2] ENTHALPIES OF SOLUTION OF POLYVINYLACETATE IN CHLOROFORM, ACETONE, AND METHANOL USING TITRATION CALORIMETRY
    BENDER, M
    HEINTZ, A
    [J]. JOURNAL OF SOLUTION CHEMISTRY, 1989, 18 (01) : 1 - 12
  • [3] CNOBLOCH H, 1983, SIEMENS FORSCH ENTW, V12, P79
  • [4] FURUTA S, 1991, P 3 INT C BATT UT EN, P49
  • [5] Hagedorn N., 1982, TM82686 NASA
  • [6] Hoberecht M. A., 1981, TM82707 NASA
  • [7] Preparation of cation exchange membrane as a separator for the all-vanadium redox flow battery
    Hwang, GJ
    Ohya, H
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1996, 120 (01) : 55 - 67
  • [8] VANADIUM REDOX CELL ELECTROLYTE OPTIMIZATION STUDIES
    KAZACOS, M
    CHENG, M
    SKYLLAS-KAZACOS, M
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 1990, 20 (03) : 463 - 467
  • [9] KUMAMOTO T, 1996, Patent No. 94273984
  • [10] KUMAMOTO T, 1996, Patent No. 94273721